Reduce the cost of signal conditioning with this loop-powered DC input two-wire transmitter which provides one isolated 4 to 20 mA output current loop in proportion to one DC input. In addition, this transmitter features a DIN rail mount package, two channels, and an input range of 0 to 100 mV DC.
Reduce the cost of signal conditioning with this loop-powered DC input two-wire transmitter which provides one isolated 4 to 20 mA output current loop in proportion to one DC input. In addition, this transmitter features a DIN rail mount package, two channels, and an input range of 0 to 100 mV DC.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Signal Conditioners category for similar products.
Or let's do a search and help you find what you need:
Ideal for remote locations, this loop-powered DC input two-wire transmitter features SnapLoc plug-in screw terminals for easy installation and low mean-time-to-repair. In addition, two or more modules can slide together and interlock for stable, high-density mounting.
Features
Applications
Input | Range: 0 to 100 mV DC Impedance: ≥100 KΩ (voltage inputs) ≤20Ω (20 mA inputs) ≤400Ω (1 mA inputs) Protection: Withstands up to 24 V DC (current input), 120 V AC (voltage input) without damage |
Output | Range: 4 to 20 mA Accuracy: ≤0.1% of full-scale input typical, ≤0.2% maximum at 73.4°F (23°C) including linearity, repeatability and hysteresis |
Channels | Two |
Supply Voltage Range | 12 to 35 V DC, each channel |
Adjustability | Front accessed 10 turn, ±5% of span for zero and span, typical |
Stability | ≤0.025%/°C of full-scale maximum Meets IEC 801-2 level 2 (4 kV) |
ESD Susceptibility | Meets IEC 801-2 level 2 (4 kV) |
Isolation | 1800 V DC or peak AC between input and output and channel to channel |
Response Time | 100 msec typical (10 to 90%) |
Temperature | Operating: -40 to 176°F (-40 to 80°C) Storage: -40 to 176°F (-40 to 80°C) |
Humidity (Non-Condensing) | Operating: 15 to 90% at 113°F (at 45°C) |
Wire Terminals | Socketed screw terminals for 12 to 22 AWG |
Agency Approvals | CSA certified per standard C22.2 (File No. LR42272) UL recognized per standard UL508 (File No. E99775) |
Dimensions | 4.59 x 4.12 x 0.88" (116.47 x 104.6 x 22.29 mm) |
Weight | 0.34 lbs (154.22 g) |
Click on a category to view a selection of compatible accessories with the Eurotherm Q501 Action I/Q Loop Powered DC Input Isolating Two-Wire Transmitter, two-channel, 0 to 100 mV DC.
Input | Range: 0 to 100 mV DC Impedance: ≥100 KΩ (voltage inputs) ≤20Ω (20 mA inputs) ≤400Ω (1 mA inputs) Protection: Withstands up to 24 V DC (current input), 120 V AC (voltage input) without damage |
Output | Range: 4 to 20 mA Accuracy: ≤0.1% of full-scale input typical, ≤0.2% maximum at 73.4°F (23°C) including linearity, repeatability and hysteresis |
Channels | Two |
Supply Voltage Range | 12 to 35 V DC, each channel |
Adjustability | Front accessed 10 turn, ±5% of span for zero and span, typical |
Stability | ≤0.025%/°C of full-scale maximum Meets IEC 801-2 level 2 (4 kV) |
ESD Susceptibility | Meets IEC 801-2 level 2 (4 kV) |
Isolation | 1800 V DC or peak AC between input and output and channel to channel |
Response Time | 100 msec typical (10 to 90%) |
Temperature | Operating: -40 to 176°F (-40 to 80°C) Storage: -40 to 176°F (-40 to 80°C) |
Humidity (Non-Condensing) | Operating: 15 to 90% at 113°F (at 45°C) |
Wire Terminals | Socketed screw terminals for 12 to 22 AWG |
Agency Approvals | CSA certified per standard C22.2 (File No. LR42272) UL recognized per standard UL508 (File No. E99775) |
Dimensions | 4.59 x 4.12 x 0.88" (116.47 x 104.6 x 22.29 mm) |
Weight | 0.34 lbs (154.22 g) |
Click on a category to view a selection of compatible accessories with the Eurotherm Q501 Action I/Q Loop Powered DC Input Isolating Two-Wire Transmitter, two-channel, 0 to 100 mV DC.