Eurotherm ULTRA SLIMPAK DC Powered DC Input Field Configurable Isolator, standard outputs, 4 to 20 mA

Model: G408-0001.V1

Eurotherm ULTRA SLIMPAK DC Powered DC Input Field Configurable Isolator, standard outputs, 4 to 20 mA

Model: G408-0001.V1

Configurable for a current range from 4 to 20 mA, this DC-powered DC input field configurable isolator provides a fully isolated DC output in proportion to a DC input. In addition, this isolator features standard inputs, ultra-slim housing, and a flexible power supply.

Configurable for a current range from 4 to 20 mA, this DC-powered DC input field configurable isolator provides a fully isolated DC output in proportion to a DC input. In addition, this isolator features standard inputs, ultra-slim housing, and a flexible power supply.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Eurotherm G408-0001.V1 Offers

Ideal for high-density installations, this DC-powered DC input field configurable isolator features a dual-function LED signal monitor.

Features

  • Eliminates ground loops
  • Field configurable input range is 4 to 20 mA
  • Field configurable output range is 4 to 20 mA
  • Ultra slim housing for high density installations
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology
  • RoHS compliant

Diagnostic LED

This unit is equipped with a dual function LED signal monitor. The green, front mounted LED indicates both DC power and input signal status. Active DC power is indicated by an illuminated LED. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below -10%, the flash rate is 4 Hz.

Applications

  • High density installations
  • Useful for eliminating ground loops, converting signal levels, and providing signal drive
  • I/O signal conditioning

Eurotherm G408-0001.V1 Specifications

Input Voltage:
Range limit: 4 to 20 mA
Impedance: <100 KΩ
Overvoltage: 400 Vrms, maximum (Intermittent); 264 Vrms,maximum (Continous)

Current:
Range limits: 1 to 100 mA
Impedance: 20 Ω, typical
Overcurrent: 170 mA RMS, maximum
Overvoltage: 60 V DC
Zero turn-up: 50% of full scale input
Span turn-down: 50% of full scale input
Common mode (input to gnd): 1800 V DC, maximum
Output Voltage:
Output: 0 to 5 V, 0 to 10 V
Source impedance: <10 Ω
Drive: 10 mA, maximum

Current:
Output: 4 to 20 mA
Source impedance: >100 KΩ

Compliance:
12 V, maximum (600Ω)
LED Indication (green) Input range: >110% (approximately) input: 8 Hz flash
< -10%(approximately) input: 4 Hz flash
Accuracy (Including Linearity, Hysteresis) <2 mA/<20 mV: ±0.35% of full scale, typical; 0.5%,maximum
>2 mA/>20 mV: ±0.1% of full scale, typical; 0.2%, maximum
Response Time (10 to 90%) 200 mSec, typical
Stability (Temperature) ±0.025% of full scale/°C,typical; ±0.05%/°C, maximum
Common Mode Rejection DC to 60 Hz: 100 dB
Isolation (Input to Output) 1800 V DC between input, output and power
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Mean Time Between Failures 60 K hours
Humidity (Non-Condensing): Operating: 15 to 95% at 45°C
Soak: 90% for 24 hours at 65°C
Temperature Range Operating: 32 to 131°F (0 to 55°C)
Storage: -13 to 158°F (-25 to 70°C)
Wire Terminals Screw terminals for 12 to 22 AWG
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No.E99775)
CE Conformance per EMC directive 2004/108/EC and Low Voltage directive 2006/95/EC
RoHS Compliant
Power Consumption: 1.5 W typical, 2.5 W maximum
Range: 9 to 30 V DC
Dimensions 3.54 x 4.34 x 0.5" (90 x 110.2 x 12.6 mm)
Weight 0.5 lbs (226.79 g)
Click here for complete specifications on the Eurotherm G408-0001.V1

What's included with the Eurotherm G408-0001.V1

  • Eurotherm ULTRA SLIMPAK DC Powered DC Input Field Configurable Isolator, standard outputs, 4 to 20 mA

Ask a question about Eurotherm ULTRA SLIMPAK DC Powered DC Input Field Configurable Isolator, standard outputs, 4 to 20 mA

Customer Reviews for the Eurotherm G408-0001.V1

Eurotherm G408-0001.V1 Offers

Ideal for high-density installations, this DC-powered DC input field configurable isolator features a dual-function LED signal monitor.

Features

  • Eliminates ground loops
  • Field configurable input range is 4 to 20 mA
  • Field configurable output range is 4 to 20 mA
  • Ultra slim housing for high density installations
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology
  • RoHS compliant

Diagnostic LED

This unit is equipped with a dual function LED signal monitor. The green, front mounted LED indicates both DC power and input signal status. Active DC power is indicated by an illuminated LED. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below -10%, the flash rate is 4 Hz.

Applications

  • High density installations
  • Useful for eliminating ground loops, converting signal levels, and providing signal drive
  • I/O signal conditioning

Eurotherm G408-0001.V1 Specifications

Input Voltage:
Range limit: 4 to 20 mA
Impedance: <100 KΩ
Overvoltage: 400 Vrms, maximum (Intermittent); 264 Vrms,maximum (Continous)

Current:
Range limits: 1 to 100 mA
Impedance: 20 Ω, typical
Overcurrent: 170 mA RMS, maximum
Overvoltage: 60 V DC
Zero turn-up: 50% of full scale input
Span turn-down: 50% of full scale input
Common mode (input to gnd): 1800 V DC, maximum
Output Voltage:
Output: 0 to 5 V, 0 to 10 V
Source impedance: <10 Ω
Drive: 10 mA, maximum

Current:
Output: 4 to 20 mA
Source impedance: >100 KΩ

Compliance:
12 V, maximum (600Ω)
LED Indication (green) Input range: >110% (approximately) input: 8 Hz flash
< -10%(approximately) input: 4 Hz flash
Accuracy (Including Linearity, Hysteresis) <2 mA/<20 mV: ±0.35% of full scale, typical; 0.5%,maximum
>2 mA/>20 mV: ±0.1% of full scale, typical; 0.2%, maximum
Response Time (10 to 90%) 200 mSec, typical
Stability (Temperature) ±0.025% of full scale/°C,typical; ±0.05%/°C, maximum
Common Mode Rejection DC to 60 Hz: 100 dB
Isolation (Input to Output) 1800 V DC between input, output and power
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Mean Time Between Failures 60 K hours
Humidity (Non-Condensing): Operating: 15 to 95% at 45°C
Soak: 90% for 24 hours at 65°C
Temperature Range Operating: 32 to 131°F (0 to 55°C)
Storage: -13 to 158°F (-25 to 70°C)
Wire Terminals Screw terminals for 12 to 22 AWG
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No.E99775)
CE Conformance per EMC directive 2004/108/EC and Low Voltage directive 2006/95/EC
RoHS Compliant
Power Consumption: 1.5 W typical, 2.5 W maximum
Range: 9 to 30 V DC
Dimensions 3.54 x 4.34 x 0.5" (90 x 110.2 x 12.6 mm)
Weight 0.5 lbs (226.79 g)
Click here for complete specifications on the Eurotherm G408-0001.V1

What's included with the Eurotherm G408-0001.V1

  • Eurotherm ULTRA SLIMPAK DC Powered DC Input Field Configurable Isolator, standard outputs, 4 to 20 mA

Ask a question about Eurotherm ULTRA SLIMPAK DC Powered DC Input Field Configurable Isolator, standard outputs, 4 to 20 mA

Customer Reviews for the Eurotherm G408-0001.V1

More Eurotherm Products