Eurotherm ULTRA SLIMPAK DC Powered DC Input Limit Alarm, 9 to 30 V DC, 0 to 20 mA

Model: G108-0001.V1

Eurotherm ULTRA SLIMPAK DC Powered DC Input Limit Alarm, 9 to 30 V DC, 0 to 20 mA

Model: G108-0001.V1

Configurable as a dual setpoint alarm, this DC-powered DC input limit alarm features high or low trips and failsafe or non-failsafe operation. In addition, input voltage spans from 10 mV to 200 V, and input current spans from 1 to 100 mA and can be field configured.

Configurable as a dual setpoint alarm, this DC-powered DC input limit alarm features high or low trips and failsafe or non-failsafe operation. In addition, input voltage spans from 10 mV to 200 V, and input current spans from 1 to 100 mA and can be field configured.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Eurotherm G108-0001.V1 Offers

Prevent false trips with this DC-powered DC input limit alarm which repeatedly samples the input to make sure it remains beyond the setpoint for 100 milliseconds, uninterrupted. In addition, the input must fall outside the deadband and stay there for 100 milliseconds to return the alarm to an untripped condition.

Features

  • Programmable hi or lo, failsafe or non-failsafe
  • Field configurable input ranges
  • 24 V DC transducer excitation
  • LED trip and input indicators
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology for enhanced reliability
  • RoHS compliant

Diagnostic LEDS

This unit is equipped with three front panel LEDs. The dual function green LED is labeled INPUT and indicates line power and input signal status. Active DC power is indicated by an illuminated LED. If this LED is off, check DC power and the wiring connection. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below 0%, it flashes at 4 Hz. Two red LEDs indicate the relay state for each setpoint. An illuminated red LED indicates the tripped condition.

Output

This unit is equipped with two SPDT (form C) relays, rated at 120 V AC or 28 V DC at 5 A. Each of these relays is independently controlled by the field configurable setpoint and deadband.

Dynamic deadband

Circuitry in the unit prevents false trips by repeatedly sampling the input. The input must remain beyond the setpoint for 100 milliseconds, uninterrupted, to qualify as a valid trip condition. Likewise, the input must fall outside the deadband and remain there for 100 milliseconds to return the alarm to an untripped condition. This results in a "dynamic deadband" (based on time) in addition to the normal deadband.

Applications

  • I/O signal conditioning

Eurotherm G108-0001.V1 Specifications

Inputs Voltage range: 10 mV to 200 V
Impedance: >100 K Ωs
Overvoltage: 200 V rms, maximum

Current:
Range: 0 to 20 mA
Impedance: 20 Ωs, typical
Overcurrent: 170 mA rms, maximum
Overvoltage: 60 V DC (protected by self resetting fuse)
Common mode (Input to ground): 1800 V DC, maximum
LED Indicators Input range (Green): >110% input: 8 Hz flash
<0% input: 4 Hz flash

Setpoint (Red)
Tripped: Solid red
Safe: Off
Limit Differentials (Deadbands) >50 mV/5 mA: 0.25 to 5% of span
<50 mV/5 mA: 1 to 5% of span
Response Time Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 msec
Normal mode (analog filtering): <250 msec, (10 to 90%)
Setpoints Effectivity: Setpoints are adjustable over 100% of the selected input span

Repeatability (constant temperature):
>50 mV/5 mA: 0.1% of full scale
<50 mV/5 mA: 0.2% of full scale
Stability Temperature: +0.05% of full scale/°C, maximum
Excitation Voltage 24 V DC, 20 mA, maximum
Common Mode Rejection DC to 60 Hz: 120 dB
Isolation 1800 V DC between contacts, input and power
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Humidity (Non-Condensing) Operating: 15 to 95% at 113°F (45°C)
Soak: 90% for 24 hours at 149°F (65°C)
Temperature Range Operating: 32 to 131°F (0 to 55°C)
Storage: -13 to 158°F (-25 to 70°C)
Relay Contacts 2 SPDT (2 form C) relays
One relay per setpoint
Current rating (resistive): 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material: Gold flash over silver alloy
Electrical life: 105 operations at rated load
Note: External relay contact protection is required for use with inductive loads
Mechanical life: 107 operations
Wire Terminations Screw terminations for 12 to 22 AWG
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and Low voltage directive 2006/95/EC.
RoHS compliant
Power Consumption: 1.5 W typical, 2.5 W maximum
Supply range: 9 to 30 V DC, inverter isolated
Dimensions 3.54 x 4.34 x 0.689" (90 x 110.2 x 17.5 mm)
Weight 0.56 lbs (254.01 g)
Click here for complete specifications on the Eurotherm G108-0001.V1

What's included with the Eurotherm G108-0001.V1

  • Eurotherm ULTRA SLIMPAK DC Powered DC Input Limit Alarm, 9 to 30 V DC, 0 to 20 mA

Ask a question about Eurotherm ULTRA SLIMPAK DC Powered DC Input Limit Alarm, 9 to 30 V DC, 0 to 20 mA

Customer Reviews for the Eurotherm G108-0001.V1

Eurotherm G108-0001.V1 Offers

Prevent false trips with this DC-powered DC input limit alarm which repeatedly samples the input to make sure it remains beyond the setpoint for 100 milliseconds, uninterrupted. In addition, the input must fall outside the deadband and stay there for 100 milliseconds to return the alarm to an untripped condition.

Features

  • Programmable hi or lo, failsafe or non-failsafe
  • Field configurable input ranges
  • 24 V DC transducer excitation
  • LED trip and input indicators
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology for enhanced reliability
  • RoHS compliant

Diagnostic LEDS

This unit is equipped with three front panel LEDs. The dual function green LED is labeled INPUT and indicates line power and input signal status. Active DC power is indicated by an illuminated LED. If this LED is off, check DC power and the wiring connection. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below 0%, it flashes at 4 Hz. Two red LEDs indicate the relay state for each setpoint. An illuminated red LED indicates the tripped condition.

Output

This unit is equipped with two SPDT (form C) relays, rated at 120 V AC or 28 V DC at 5 A. Each of these relays is independently controlled by the field configurable setpoint and deadband.

Dynamic deadband

Circuitry in the unit prevents false trips by repeatedly sampling the input. The input must remain beyond the setpoint for 100 milliseconds, uninterrupted, to qualify as a valid trip condition. Likewise, the input must fall outside the deadband and remain there for 100 milliseconds to return the alarm to an untripped condition. This results in a "dynamic deadband" (based on time) in addition to the normal deadband.

Applications

  • I/O signal conditioning

Eurotherm G108-0001.V1 Specifications

Inputs Voltage range: 10 mV to 200 V
Impedance: >100 K Ωs
Overvoltage: 200 V rms, maximum

Current:
Range: 0 to 20 mA
Impedance: 20 Ωs, typical
Overcurrent: 170 mA rms, maximum
Overvoltage: 60 V DC (protected by self resetting fuse)
Common mode (Input to ground): 1800 V DC, maximum
LED Indicators Input range (Green): >110% input: 8 Hz flash
<0% input: 4 Hz flash

Setpoint (Red)
Tripped: Solid red
Safe: Off
Limit Differentials (Deadbands) >50 mV/5 mA: 0.25 to 5% of span
<50 mV/5 mA: 1 to 5% of span
Response Time Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 msec
Normal mode (analog filtering): <250 msec, (10 to 90%)
Setpoints Effectivity: Setpoints are adjustable over 100% of the selected input span

Repeatability (constant temperature):
>50 mV/5 mA: 0.1% of full scale
<50 mV/5 mA: 0.2% of full scale
Stability Temperature: +0.05% of full scale/°C, maximum
Excitation Voltage 24 V DC, 20 mA, maximum
Common Mode Rejection DC to 60 Hz: 120 dB
Isolation 1800 V DC between contacts, input and power
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Humidity (Non-Condensing) Operating: 15 to 95% at 113°F (45°C)
Soak: 90% for 24 hours at 149°F (65°C)
Temperature Range Operating: 32 to 131°F (0 to 55°C)
Storage: -13 to 158°F (-25 to 70°C)
Relay Contacts 2 SPDT (2 form C) relays
One relay per setpoint
Current rating (resistive): 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material: Gold flash over silver alloy
Electrical life: 105 operations at rated load
Note: External relay contact protection is required for use with inductive loads
Mechanical life: 107 operations
Wire Terminations Screw terminations for 12 to 22 AWG
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and Low voltage directive 2006/95/EC.
RoHS compliant
Power Consumption: 1.5 W typical, 2.5 W maximum
Supply range: 9 to 30 V DC, inverter isolated
Dimensions 3.54 x 4.34 x 0.689" (90 x 110.2 x 17.5 mm)
Weight 0.56 lbs (254.01 g)
Click here for complete specifications on the Eurotherm G108-0001.V1

What's included with the Eurotherm G108-0001.V1

  • Eurotherm ULTRA SLIMPAK DC Powered DC Input Limit Alarm, 9 to 30 V DC, 0 to 20 mA

Ask a question about Eurotherm ULTRA SLIMPAK DC Powered DC Input Limit Alarm, 9 to 30 V DC, 0 to 20 mA

Customer Reviews for the Eurotherm G108-0001.V1

More Eurotherm Products