Eurotherm ULTRA SLIMPAK DC Powered RTD Input Limit Alarm, 9 to 30 V DC, 0 to 250°C

Model: G118-0002.V1

Eurotherm ULTRA SLIMPAK DC Powered RTD Input Limit Alarm, 9 to 30 V DC, 0 to 250°C

Model: G118-0002.V1

Configurable as a dual setpoint alarm, this DC-powered RTD input limit alarm features high or low trips and failsafe or non-failsafe operation. In addition, this alarm features a temperature range of 0 to 250°C to ensure accuracy and maximize setpoint resolution.

Configurable as a dual setpoint alarm, this DC-powered RTD input limit alarm features high or low trips and failsafe or non-failsafe operation. In addition, this alarm features a temperature range of 0 to 250°C to ensure accuracy and maximize setpoint resolution.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Modules category for similar products.

Or let's do a search and help you find what you need:


Eurotherm G118-0002.V1 Offers

Prevent false trips with this DC-powered RTD input limit alarm which repeatedly samples the input to make sure it remains beyond the setpoint for 100 milliseconds, uninterrupted. In addition, the input must fall outside the deadband and stay there for 100 milliseconds to return the alarm to an untripped condition.

Features

  • Programmable hi or lo, failsafe or non-failsafe
  • Field configurable ranges for platinum
  • Ultra slim housing for high density installations
  • LED trip and input indicators
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology for enhanced reliability
  • RoHS compliant

Diagnostic LEDS

This unit is equipped with three front panel LEDs. The dual function green LED is labeled INPUT and indicates line power and input signal status. Active DC power is indicated by an illuminated LED. If this LED is off, check DC power and the wiring connection. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below 0%, it flashes at 4 Hz. Two red LEDs indicate the relay state for each setpoint. An illuminated red LED indicates the tripped condition.

Output

This unit is equipped with two SPDT (form C) relays, rated at 120 V AC or 28 V DC at 5 A. Each of these relays is independently controlled by the field configurable setpoint and deadband.

Dynamic deadband

Circuitry in the unit prevents false trips by repeatedly sampling the input. The input must remain beyond the setpoint for 100 milliseconds, uninterrupted, to qualify as a valid trip condition. Likewise, the input must fall outside the deadband and remain there for 100 milliseconds to return the alarm to an untripped condition. This results in a "dynamic deadband" (based on time) in addition to the normal deadband.

Applications

  • I/O signal conditioning

Eurotherm G118-0002.V1 Specifications

Inputs Sensors: Pt100, Pt500, Pt1000 (0.00385Ω/°C); Cu10, Cu100; Ni120, NiFe604
Sensor connection: 3-wire
Input range: 0 to 250°C
Isolation 1800 V DC between contacts, input and power
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Excitation Current (Maximum) <2 mA for Pt100, Pt500, Pt1000, Ni120, Cu100 or NiFe604
<10 mA for Cu10
Humidity (Non-Condensing) Operating: 15 to 95% at 45°C
Soak: 90% for 24 hours at 65°C
Leadwire Resistance: 40% of base sensor resistance or 100 Ωs (whichever is less), maximum per lead
Effect: Less than 1% of selected span over entire leadwire resistance range
Input Protection Normal mode: Withstands ±5 V DC
Common mode (input to gnd): 1800 V DC, maximum
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -13 to 158°F (-25 to 75°C)
LED Indicators Input range (green): >110% input: 8 Hz flash;>-10% input: 4 Hz flash
Setpoint (red): Tripped: Solid red; Safe: Off
Relay Contacts 2 SPDT (2 form C) relays, 1 relay per setpoint
Current rating (resistive) 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material: Gold flash over silver alloy
Electrical life: 105 operations at rated load
Note: External relay protection is required for use with inductive loads
Mechanical life: 107operations
Stability Line voltage: ±0.01%/%, maximum
Temperature: ±0.05% of full scale/°C, maximum
Common Mode Rejection DC to 60 Hz: 120 dB
>60 Hz: 100 dB
Limit Differentials (Deadbands) 0.25 to 5% of span
Setpoints Effectivity: Setpoints are adjustable over 100% of the selected input span
Repeatability (constant temperature): ±0.2% of full scale
Response Time Dynamic deadband: Relay status will change when proper setpoint/ process condition exists for 100 msecond
Normal mode (analog filtering): <250 mSec, (10 to 90%)
Power Consumption: 1.5 W typical, 2.5 W maximum
Supply range: 9 to 30 V DC, inverter isolated
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No. E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/ 95/EC
RoHS compliant
Dimensions 3.54 x 4.34 x 0.689" (90 x 110.2 x 17.5 mm)
Weight 0.56 lbs (254.01 g)
Click here for complete specifications on the Eurotherm G118-0002.V1

What's included with the Eurotherm G118-0002.V1

  • Eurotherm ULTRA SLIMPAK DC Powered RTD Input Limit Alarm, 9 to 30 V DC, 0 to 250°C

Ask a question about Eurotherm ULTRA SLIMPAK DC Powered RTD Input Limit Alarm, 9 to 30 V DC, 0 to 250°C

Customer Reviews for the Eurotherm G118-0002.V1

Eurotherm G118-0002.V1 Offers

Prevent false trips with this DC-powered RTD input limit alarm which repeatedly samples the input to make sure it remains beyond the setpoint for 100 milliseconds, uninterrupted. In addition, the input must fall outside the deadband and stay there for 100 milliseconds to return the alarm to an untripped condition.

Features

  • Programmable hi or lo, failsafe or non-failsafe
  • Field configurable ranges for platinum
  • Ultra slim housing for high density installations
  • LED trip and input indicators
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology for enhanced reliability
  • RoHS compliant

Diagnostic LEDS

This unit is equipped with three front panel LEDs. The dual function green LED is labeled INPUT and indicates line power and input signal status. Active DC power is indicated by an illuminated LED. If this LED is off, check DC power and the wiring connection. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below 0%, it flashes at 4 Hz. Two red LEDs indicate the relay state for each setpoint. An illuminated red LED indicates the tripped condition.

Output

This unit is equipped with two SPDT (form C) relays, rated at 120 V AC or 28 V DC at 5 A. Each of these relays is independently controlled by the field configurable setpoint and deadband.

Dynamic deadband

Circuitry in the unit prevents false trips by repeatedly sampling the input. The input must remain beyond the setpoint for 100 milliseconds, uninterrupted, to qualify as a valid trip condition. Likewise, the input must fall outside the deadband and remain there for 100 milliseconds to return the alarm to an untripped condition. This results in a "dynamic deadband" (based on time) in addition to the normal deadband.

Applications

  • I/O signal conditioning

Eurotherm G118-0002.V1 Specifications

Inputs Sensors: Pt100, Pt500, Pt1000 (0.00385Ω/°C); Cu10, Cu100; Ni120, NiFe604
Sensor connection: 3-wire
Input range: 0 to 250°C
Isolation 1800 V DC between contacts, input and power
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Excitation Current (Maximum) <2 mA for Pt100, Pt500, Pt1000, Ni120, Cu100 or NiFe604
<10 mA for Cu10
Humidity (Non-Condensing) Operating: 15 to 95% at 45°C
Soak: 90% for 24 hours at 65°C
Leadwire Resistance: 40% of base sensor resistance or 100 Ωs (whichever is less), maximum per lead
Effect: Less than 1% of selected span over entire leadwire resistance range
Input Protection Normal mode: Withstands ±5 V DC
Common mode (input to gnd): 1800 V DC, maximum
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -13 to 158°F (-25 to 75°C)
LED Indicators Input range (green): >110% input: 8 Hz flash;>-10% input: 4 Hz flash
Setpoint (red): Tripped: Solid red; Safe: Off
Relay Contacts 2 SPDT (2 form C) relays, 1 relay per setpoint
Current rating (resistive) 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material: Gold flash over silver alloy
Electrical life: 105 operations at rated load
Note: External relay protection is required for use with inductive loads
Mechanical life: 107operations
Stability Line voltage: ±0.01%/%, maximum
Temperature: ±0.05% of full scale/°C, maximum
Common Mode Rejection DC to 60 Hz: 120 dB
>60 Hz: 100 dB
Limit Differentials (Deadbands) 0.25 to 5% of span
Setpoints Effectivity: Setpoints are adjustable over 100% of the selected input span
Repeatability (constant temperature): ±0.2% of full scale
Response Time Dynamic deadband: Relay status will change when proper setpoint/ process condition exists for 100 msecond
Normal mode (analog filtering): <250 mSec, (10 to 90%)
Power Consumption: 1.5 W typical, 2.5 W maximum
Supply range: 9 to 30 V DC, inverter isolated
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No. E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/ 95/EC
RoHS compliant
Dimensions 3.54 x 4.34 x 0.689" (90 x 110.2 x 17.5 mm)
Weight 0.56 lbs (254.01 g)
Click here for complete specifications on the Eurotherm G118-0002.V1

What's included with the Eurotherm G118-0002.V1

  • Eurotherm ULTRA SLIMPAK DC Powered RTD Input Limit Alarm, 9 to 30 V DC, 0 to 250°C