Eurotherm ULTRA SLIMPAK Frequency Input Field Configurable Isolator, 4 to 20 mA, 0 to 1000 Hz

Model: G478-0001.V1

Eurotherm ULTRA SLIMPAK Frequency Input Field Configurable Isolator, 4 to 20 mA, 0 to 1000 Hz

Model: G478-0001.V1

Configurable for virtually any frequency input to DC signal output within a 0 to 1000 Hz range, this frequency input field configurable isolator provides an isolated DC output in proportion to a frequency input. In addition, this isolator features an ultra-slim housing and a flexible power supply.

Configurable for virtually any frequency input to DC signal output within a 0 to 1000 Hz range, this frequency input field configurable isolator provides an isolated DC output in proportion to a frequency input. In addition, this isolator features an ultra-slim housing and a flexible power supply.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Eurotherm G478-0001.V1 Offers

Ideal for high-density installations, this frequency input field configurable isolator features a wide ranging zero and span adjustability.

Features

  • Field configurable input range from 0 to 1000 Hz
  • Eliminates ground loops
  • Field configurable outputs: 4 to 20 mA
  • Ultra slim housing for high density installations
  • 150 mV to 150 V input amplitude level
  • Touch-Cal™ for simplified ranging
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology for enhanced reliability
  • RoHS compliant

Touch-CAL™ Technology

This unit utilizes 'Touch-Cal' technology to greatly simplify configuration. To set the input frequency range, simply apply the high input frequency and push the CAL button while the INPUT LED is lit. The low input frequency is then applied and pushing the CAL button once again stores the low frequency input. The high and low ranges are stored in non-volatile memory and correspond to the high and low output range which is selected via DIP switches. To precisely adjust the output, the user adjusts the input frequency while the OUTPUT LED is lit until the desired output level is achieved. The output levels are locked-in by pushing the CAL button. Status LEDs show the operation mode of the device.

Status LEDs

This unit utilizes three status LEDs. The green LED varies intensity as the frequency changes from 0 to 100% of full scale range (e.g., for a configuration of 0 to 1000 Hz, the LED will be off with an input of 0 Hz and fully illuminated at 1000 Hz. With an input of 500 Hz, the LED will be dim). If the input signal is 10% more than full scale range (over-ranged), the LED will flash at 8 Hz. The yellow INPUT LED denotes input programming modes. The red OUTPUT LED denotes output programming modes.

Applications

  • High density installations
  • Eliminates ground loops and interfacing pulse output transducers, such as turbine flow meters and magnetic pick-ups, to data acquisition and control systems
  • I/O signal conditioning

Eurotherm G478-0001.V1 Specifications

Input Frequency input:
Full scale range: 0 to 1000 Hz
Amplitude range: 150 mVp to 150 Vrms
Impedance: >10 KΩ
Over-voltage: 180 Vrms, maximum
Over-range: 20 KHz, maximum
Common mode (input to gnd): 1800 V DC, maximum
Zero turn-up: 99% of full scale range (9998 Hz)
Span turn-down: 99% of full scale range (2 Hz)
Output Voltage:
Output: 0 to 5 V, 0 to 10 V
Source impedance: <100 Ω
Drive: 10 mA, maximum (1 KΩ, minimum at 10 V)

Current:
Output: 4 to 20 mA
Source impedance: >100 KΩ

Compliance: 12 V, maximum (600 Ω, maximum)
Accuracy (Including Linearity, Hysteresis) ±0.1% of selected range at 77°F (25°C)
Stability ±0.025%/°C maximum of selected range
Response Time (10 to 90%) 3 input cycles + 250 ms
Common Mode Rejection DC: 100 dB
>60 Hz: 80 dB
Isolation 1800 V DC between input, output and power
LED Indication (Green) LEVEL (green): Lit when power is on, input >110% then 8 Hz flash, input <-10% then 4 Hz flash
INPUT (yellow): Input range programming status
OUTPUT (red): Output range programming status
Humidity (Non-Condensing) Operating: 15 to 95% at 113°F (45°C)
Soak: 90% for 24 hours at 149°F (65°C)
Temperature Range Operating: 32 to 131°F (0 to 55°C)
Storage: -13 to 158°F (-25 to 70°C)
Wire Terminations Screw terminals for 12 to 22 AWG
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC
RoHS Compliant
Power Consumption: 1.5 W typical, 2.5 W maximum
Range: 9 to 30 V DC
Dimensions 3.54 x 4.34 x 0.5" (90 x 110.2 x 12.6 mm)
Weight 0.5 lbs (226.79 g)
Click here for complete specifications on the Eurotherm G478-0001.V1

What's included with the Eurotherm G478-0001.V1

  • Eurotherm ULTRA SLIMPAK Frequency Input Field Configurable Isolator, 4 to 20 mA, 0 to 1000 Hz

Ask a question about Eurotherm ULTRA SLIMPAK Frequency Input Field Configurable Isolator, 4 to 20 mA, 0 to 1000 Hz

Customer Reviews for the Eurotherm G478-0001.V1

Eurotherm G478-0001.V1 Offers

Ideal for high-density installations, this frequency input field configurable isolator features a wide ranging zero and span adjustability.

Features

  • Field configurable input range from 0 to 1000 Hz
  • Eliminates ground loops
  • Field configurable outputs: 4 to 20 mA
  • Ultra slim housing for high density installations
  • 150 mV to 150 V input amplitude level
  • Touch-Cal™ for simplified ranging
  • Flexible power supply accepts 9 to 30 V DC
  • ASIC technology for enhanced reliability
  • RoHS compliant

Touch-CAL™ Technology

This unit utilizes 'Touch-Cal' technology to greatly simplify configuration. To set the input frequency range, simply apply the high input frequency and push the CAL button while the INPUT LED is lit. The low input frequency is then applied and pushing the CAL button once again stores the low frequency input. The high and low ranges are stored in non-volatile memory and correspond to the high and low output range which is selected via DIP switches. To precisely adjust the output, the user adjusts the input frequency while the OUTPUT LED is lit until the desired output level is achieved. The output levels are locked-in by pushing the CAL button. Status LEDs show the operation mode of the device.

Status LEDs

This unit utilizes three status LEDs. The green LED varies intensity as the frequency changes from 0 to 100% of full scale range (e.g., for a configuration of 0 to 1000 Hz, the LED will be off with an input of 0 Hz and fully illuminated at 1000 Hz. With an input of 500 Hz, the LED will be dim). If the input signal is 10% more than full scale range (over-ranged), the LED will flash at 8 Hz. The yellow INPUT LED denotes input programming modes. The red OUTPUT LED denotes output programming modes.

Applications

  • High density installations
  • Eliminates ground loops and interfacing pulse output transducers, such as turbine flow meters and magnetic pick-ups, to data acquisition and control systems
  • I/O signal conditioning

Eurotherm G478-0001.V1 Specifications

Input Frequency input:
Full scale range: 0 to 1000 Hz
Amplitude range: 150 mVp to 150 Vrms
Impedance: >10 KΩ
Over-voltage: 180 Vrms, maximum
Over-range: 20 KHz, maximum
Common mode (input to gnd): 1800 V DC, maximum
Zero turn-up: 99% of full scale range (9998 Hz)
Span turn-down: 99% of full scale range (2 Hz)
Output Voltage:
Output: 0 to 5 V, 0 to 10 V
Source impedance: <100 Ω
Drive: 10 mA, maximum (1 KΩ, minimum at 10 V)

Current:
Output: 4 to 20 mA
Source impedance: >100 KΩ

Compliance: 12 V, maximum (600 Ω, maximum)
Accuracy (Including Linearity, Hysteresis) ±0.1% of selected range at 77°F (25°C)
Stability ±0.025%/°C maximum of selected range
Response Time (10 to 90%) 3 input cycles + 250 ms
Common Mode Rejection DC: 100 dB
>60 Hz: 80 dB
Isolation 1800 V DC between input, output and power
LED Indication (Green) LEVEL (green): Lit when power is on, input >110% then 8 Hz flash, input <-10% then 4 Hz flash
INPUT (yellow): Input range programming status
OUTPUT (red): Output range programming status
Humidity (Non-Condensing) Operating: 15 to 95% at 113°F (45°C)
Soak: 90% for 24 hours at 149°F (65°C)
Temperature Range Operating: 32 to 131°F (0 to 55°C)
Storage: -13 to 158°F (-25 to 70°C)
Wire Terminations Screw terminals for 12 to 22 AWG
EMC Compliance (CE Mark) EMC: EN61326-1:2013
Safety: EN61010-2:2013
Agency Approvals CSA certified per standard C22.2, No. 0-M91 and 142-M1987 (File No. LR42272)
UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC
RoHS Compliant
Power Consumption: 1.5 W typical, 2.5 W maximum
Range: 9 to 30 V DC
Dimensions 3.54 x 4.34 x 0.5" (90 x 110.2 x 12.6 mm)
Weight 0.5 lbs (226.79 g)
Click here for complete specifications on the Eurotherm G478-0001.V1

What's included with the Eurotherm G478-0001.V1

  • Eurotherm ULTRA SLIMPAK Frequency Input Field Configurable Isolator, 4 to 20 mA, 0 to 1000 Hz

Ask a question about Eurotherm ULTRA SLIMPAK Frequency Input Field Configurable Isolator, 4 to 20 mA, 0 to 1000 Hz

Customer Reviews for the Eurotherm G478-0001.V1

More Eurotherm Products