Eurotherm V565-0000-0C High Performance Loop Powered LCD Indicator, 10 to 50 mA, conduit housing

Model: V565-0000-0C

Eurotherm V565-0000-0C High Performance Loop Powered LCD Indicator, 10 to 50 mA, conduit housing

Model: V565-0000-0C

Eliminate an extra power supply with this high-performance loop-powered LCD indicator which provides a 3½ digit LCD indication with a 1 V loop drop. In addition, this indicator features a conduit housing for the internal mounting of a T700 series two-wire transmitter.

Eliminate an extra power supply with this high-performance loop-powered LCD indicator which provides a 3½ digit LCD indication with a 1 V loop drop. In addition, this indicator features a conduit housing for the internal mounting of a T700 series two-wire transmitter.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Eurotherm V565-0000-0C Offers

Ideal for hazardous installations, this high-performance loop-powered LCD indicator features FM and CSA safety approval. Additionally, this indicator features a large, 3½ digit, 0.8" (20.32 mm) high LCD to provide clear visibility and switch selectable mA inputs and decimal points.

Features

  • Loop drop of only 1 V provides extra compliance
  • Selectable square root mode for flow applications
  • LCD readable from 30' (9.14 m)
  • Switch selectable 4 to 20 mA, 10 to 50 mA, decimal point and direct/reverse "display gain"
  • Front panel
  • FM and CSA safety approval for hazardous installations
  • Wide-ranging 3½ digit display
  • Conduit housing, allows internal mounting of T700 series two-wire transmitter

The unit is useful in any application requiring a wide-ranging 3½ digit display from a 4 to 20 mA or 10 to 50 mA current source. The enclosure constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; electronics inside the enclosure against ingress of solid foreign objects; harmful effects on the electronics due to the ingress of water (rain, sleet, snow); and the external mechanism(s) remain operable when ice laden. The unit is ideal for displaying process variables in local and remote areas where line power is not available or impractical.

Applications

  • Hazardous installations

Eurotherm V565-0000-0C Specifications

Input Current ranges: 4 to 20 mA and 10 to 50 mA, switch selectable
Current limits: Minimum: 3 mA, maximum: 220 mA (Fuse)
Voltage drop: 4 to 20 mA: 1 V maximum at 20 mA, 10 to 50 mA: 1.4 V maximum at 50 mA
Display Reading update: Two readings per second

Readout:
Type: 0.8" (20.32 mm) high liquid crystal, 3½ digit (1999)
Decimal point indication: Switch-selectable, four positions 1.9.9.9.
Dummy zero: Switch-selectable trailing zero, e.g., 19,990
Direction: Jumper-selectable, underrange (below -1999): Displays -1, overrange (above 1999): Displays 1

Calibration:
Zero (4 mA/10 mA): Adjustable from -1999 to 1999
Span (20 mA/50 mA): Adjustable from 0 to 3998
Accuracy at 25 ±41°F (5°C) Linear: <±0.1% of span counts, ±1 count
Square-root: <±0.1% of span counts, ±1 count (from 1 to 100% of span)
Ripple Rejection 1 count error with 1 mA p-p ripple at 50 Hz
Screws Front panel: 10 to 32, brass with corrosion resistant stainless steel plating: MIL-W-52263C (MR)
Rear electrical: 6 to 32, nickel plated brass
Terminals Standard: 6 to 32 screw (accepts 0.2" [5.08 mm]) ring lug
Conduit mount (Opt C): Screw clamp, 12 AWG wire gauge, maximum
Temperature Coefficient (Standard calibration: 14 to 158°F [-10 to 70°C]; linear mode):
Zero: ±0.1 counts/°C, ±1 count, typical, ±0.2 counts/°C, ±1 count, maximum
Span (1000 to 3998): ±150 ppm/°C, ±1 count, maximum
Span (100 to 999): 150 ppm/°C + 0.95(1000 - Span), ±1 count, maximum

Coefficient (square-root): Equivalent to 1 uA/°C maximum input drift

Range:
Standard: 14 to 158°F (-10 to 70°C)
Storage: -67 to 176°F (-55 to 80°C)
FM Entity Parameters Type 3S, T4, 14°F (-10°C) - <Ta - <158°F (70°C)
Vmax = 33 V
Imax = 178.5 mA
Ci = 0 mF
Li = 0 mH
Agency Approval FM approved intrinsically safe for hazardous locations, certificate No.FM17US0096
CSA approved intrinsically safe for hazardous locations, (File No.LR422272-45)
Power 2.5 mW maximum at 3.5 mA input
Dimensions 6.06 x 3.56 x 3.68" (153.9 x 90.4 x 93.6 mm)
Weight 2.2 lbs (997.9 g)
Click here for complete specifications on the Eurotherm V565-0000-0C

What's included with the Eurotherm V565-0000-0C

  • LCD Indicator
  • External Mounting Bracket

Ask a question about Eurotherm V565-0000-0C High Performance Loop Powered LCD Indicator, 10 to 50 mA, conduit housing

Customer Reviews for the Eurotherm V565-0000-0C

Eurotherm V565-0000-0C Offers

Ideal for hazardous installations, this high-performance loop-powered LCD indicator features FM and CSA safety approval. Additionally, this indicator features a large, 3½ digit, 0.8" (20.32 mm) high LCD to provide clear visibility and switch selectable mA inputs and decimal points.

Features

  • Loop drop of only 1 V provides extra compliance
  • Selectable square root mode for flow applications
  • LCD readable from 30' (9.14 m)
  • Switch selectable 4 to 20 mA, 10 to 50 mA, decimal point and direct/reverse "display gain"
  • Front panel
  • FM and CSA safety approval for hazardous installations
  • Wide-ranging 3½ digit display
  • Conduit housing, allows internal mounting of T700 series two-wire transmitter

The unit is useful in any application requiring a wide-ranging 3½ digit display from a 4 to 20 mA or 10 to 50 mA current source. The enclosure constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; electronics inside the enclosure against ingress of solid foreign objects; harmful effects on the electronics due to the ingress of water (rain, sleet, snow); and the external mechanism(s) remain operable when ice laden. The unit is ideal for displaying process variables in local and remote areas where line power is not available or impractical.

Applications

  • Hazardous installations

Eurotherm V565-0000-0C Specifications

Input Current ranges: 4 to 20 mA and 10 to 50 mA, switch selectable
Current limits: Minimum: 3 mA, maximum: 220 mA (Fuse)
Voltage drop: 4 to 20 mA: 1 V maximum at 20 mA, 10 to 50 mA: 1.4 V maximum at 50 mA
Display Reading update: Two readings per second

Readout:
Type: 0.8" (20.32 mm) high liquid crystal, 3½ digit (1999)
Decimal point indication: Switch-selectable, four positions 1.9.9.9.
Dummy zero: Switch-selectable trailing zero, e.g., 19,990
Direction: Jumper-selectable, underrange (below -1999): Displays -1, overrange (above 1999): Displays 1

Calibration:
Zero (4 mA/10 mA): Adjustable from -1999 to 1999
Span (20 mA/50 mA): Adjustable from 0 to 3998
Accuracy at 25 ±41°F (5°C) Linear: <±0.1% of span counts, ±1 count
Square-root: <±0.1% of span counts, ±1 count (from 1 to 100% of span)
Ripple Rejection 1 count error with 1 mA p-p ripple at 50 Hz
Screws Front panel: 10 to 32, brass with corrosion resistant stainless steel plating: MIL-W-52263C (MR)
Rear electrical: 6 to 32, nickel plated brass
Terminals Standard: 6 to 32 screw (accepts 0.2" [5.08 mm]) ring lug
Conduit mount (Opt C): Screw clamp, 12 AWG wire gauge, maximum
Temperature Coefficient (Standard calibration: 14 to 158°F [-10 to 70°C]; linear mode):
Zero: ±0.1 counts/°C, ±1 count, typical, ±0.2 counts/°C, ±1 count, maximum
Span (1000 to 3998): ±150 ppm/°C, ±1 count, maximum
Span (100 to 999): 150 ppm/°C + 0.95(1000 - Span), ±1 count, maximum

Coefficient (square-root): Equivalent to 1 uA/°C maximum input drift

Range:
Standard: 14 to 158°F (-10 to 70°C)
Storage: -67 to 176°F (-55 to 80°C)
FM Entity Parameters Type 3S, T4, 14°F (-10°C) - <Ta - <158°F (70°C)
Vmax = 33 V
Imax = 178.5 mA
Ci = 0 mF
Li = 0 mH
Agency Approval FM approved intrinsically safe for hazardous locations, certificate No.FM17US0096
CSA approved intrinsically safe for hazardous locations, (File No.LR422272-45)
Power 2.5 mW maximum at 3.5 mA input
Dimensions 6.06 x 3.56 x 3.68" (153.9 x 90.4 x 93.6 mm)
Weight 2.2 lbs (997.9 g)
Click here for complete specifications on the Eurotherm V565-0000-0C

What's included with the Eurotherm V565-0000-0C

  • LCD Indicator
  • External Mounting Bracket

Ask a question about Eurotherm V565-0000-0C High Performance Loop Powered LCD Indicator, 10 to 50 mA, conduit housing