Eliminate wasted power with this DC-powered frequency input-isolating signal conditioner featuring SmartPower to control its output supply. In addition, this alarm accepts a frequency of up to 10 kHz with a minimum input span of 2 Hz, and the input amplitude can range from 150 mVp to 150 Vrms.
Eliminate wasted power with this DC-powered frequency input-isolating signal conditioner featuring SmartPower to control its output supply. In addition, this alarm accepts a frequency of up to 10 kHz with a minimum input span of 2 Hz, and the input amplitude can range from 150 mVp to 150 Vrms.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Get greater accuracy and better stability with this signal conditionerswhich features Smart Power that helps eliminate wasted power for low loop resistance loads in the current output mode.
Features
Smart Power
This signal conditioner uses Smart Power to control its output supply. Smart Power automatically adjusts the voltage to drive the output loop to the required current. A low impedance current loop will subsequently require less voltage than a loop with higher impedance. Previous designs provided only a single supply at the highest voltage required to drive the highest impedance load. Using Smart Power results in power savings and reduces the operating temperature of the signal conditioner.
Enhanced LED diagnostics
Other than when executing the pushbutton calibration routine, the LEDs blink under the following conditions:
An Under Range condition exists when the signal is lower than the operational low value minus 6.25% of the operational span. An Over Range condition exists when the signal is higher than the operational high value plus 6.25% of the operational span. A voltage output short circuit may cause an under range condition (RED blinking at 2 Hz rate). A current output open circuit may cause an over range condition (RED blinking at an 8 Hz rate). There could be two or more LEDs blinking at the same time, which means the module has more than one error condition. Only when all error conditions have been removed, will the LEDs be back to normal (Green ON, Red and Yellow Off).
Input | Frequency input range: 0 to 10 kHz Minimum input span: 2 Hz Amplitude (switch selectable): Low range: 150 mVp to 50 Vrms High range: 500 mVp to 150 Vrms |
Output | Voltage: 0 to 10 V DC; Source impedance: 10 Ω Drive: 10 mA Current: 0 to 20 mA Source impedance: >100 kΩ Compliance: 20 V at 20 mA (1 kΩ maximum) |
Output Accuracy | ±0.05% of full scale local range |
Response Time | 100 ms + 3 input cycles (10 to 90%) typical |
Stability | ±100 ppm of full scale/°C (±0.01%/°C) |
Common Mode Rejection | 60 Hz: >90 dB DC: >120 dB |
Isolation | Input to output to power: 1800 V DC |
ESD Susceptibility | Capable of meeting IEC801-2 level 3 (8 kV) |
Host Module Interface | IR Link |
Humidity (non-condensing) | Operating: 15 to 95% RHNC at 113°F (45°C) Storage: 90% RHNC for 24 hours at 140°F (60°C) |
Temperature | Operating: 32 to 140°F (0 to 60°C) Storage: -13 to 185°F (-25 to 85°C) |
Agency Approvals (EMC and Safety) | UL recognized per standard UL508 (File No.E99775) CE Conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (input <75 V DC, only) RoHS compliant |
Power | 9 to 30 V DC, 1 W typical, 2 W maximum |
Dimensions | 4.39 x 3.54 x 0.5" (111.6 x 90 x 12.7 mm) DIN rail case |
Click on a category to view a selection of compatible accessories with the Eurotherm WV478-2000.V1 DC Powered Frequency Input Isolating Signal Conditioner, 0 to 10 kHz, 0 to 10 V DC.
Input | Frequency input range: 0 to 10 kHz Minimum input span: 2 Hz Amplitude (switch selectable): Low range: 150 mVp to 50 Vrms High range: 500 mVp to 150 Vrms |
Output | Voltage: 0 to 10 V DC; Source impedance: 10 Ω Drive: 10 mA Current: 0 to 20 mA Source impedance: >100 kΩ Compliance: 20 V at 20 mA (1 kΩ maximum) |
Output Accuracy | ±0.05% of full scale local range |
Response Time | 100 ms + 3 input cycles (10 to 90%) typical |
Stability | ±100 ppm of full scale/°C (±0.01%/°C) |
Common Mode Rejection | 60 Hz: >90 dB DC: >120 dB |
Isolation | Input to output to power: 1800 V DC |
ESD Susceptibility | Capable of meeting IEC801-2 level 3 (8 kV) |
Host Module Interface | IR Link |
Humidity (non-condensing) | Operating: 15 to 95% RHNC at 113°F (45°C) Storage: 90% RHNC for 24 hours at 140°F (60°C) |
Temperature | Operating: 32 to 140°F (0 to 60°C) Storage: -13 to 185°F (-25 to 85°C) |
Agency Approvals (EMC and Safety) | UL recognized per standard UL508 (File No.E99775) CE Conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (input <75 V DC, only) RoHS compliant |
Power | 9 to 30 V DC, 1 W typical, 2 W maximum |
Dimensions | 4.39 x 3.54 x 0.5" (111.6 x 90 x 12.7 mm) DIN rail case |
Click on a category to view a selection of compatible accessories with the Eurotherm WV478-2000.V1 DC Powered Frequency Input Isolating Signal Conditioner, 0 to 10 kHz, 0 to 10 V DC.