Measures air velocity, airflow, and temperature, this thermo-anemometer allows for more precise readings on larger ducts. In addition, this meter features a large, easy-to-read backlit LCD that includes primary (upper) and secondary (lower) displays and numerous status indicators.
Measures air velocity, airflow, and temperature, this thermo-anemometer allows for more precise readings on larger ducts. In addition, this meter features a large, easy-to-read backlit LCD that includes primary (upper) and secondary (lower) displays and numerous status indicators.
Features
Applications
| Air Velocity | |
| m/s | Range: 0.2 to 30 m/s Resolution: 0.01 m/s Accuracy: ±(1.5% rdg + 0.3 m/s) |
| ft/min | Range: 40 to 5900 ft/min Resolution: 1 ft/min Accuracy: ±(1.5% rdg + 59 ft/min) |
| Air Flow (Volume) | |
| CMM | Range: 0 to 99999 m3/min Resolution: 0.1 up to 9999.9 then 1.0 Area range: 0 to 99999 cm2 |
| CFM | Range: 0 to 99999 ft3/min Resolution: 0.1 up to 9999.9 then 1.0 Area range: 0 to 99999 in2 |
| Air Temperature | |
| °F/C | Range: -4 to 140°F (-20 to 60°C) Resolution: 0.1°F/C Accuracy: ±1.1°F (-5 to 122°F), ±2.2°F (123 to 140°F); ±0.6°C (-20 to 50°C), ±1.2°C (51 to 60°C) |
| General Specifications | |
| Circuit | Custom LSI microprocessor |
| Display | Dual function 0.5" (13 mm) 4-digit LCD |
| Sampling Rate | 1 reading per second approximately |
| Sensors | Air velocity/flow: Conventional angled vane arms with low-friction ball bearing Temperature: NTC-type precision thermistor |
| Automatic Power-Off | Auto shut off after 20 minutes to preserve battery life (sleep mode) |
| Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: 14 to 122°F (-10 to 50°C) |
| Humidity | Operating <80% RH Storage: <90% RH |
| Operating Altitude | 7000' (2000 m) maximum |
| Battery | Type: 4 x AAA 1.5 V batteries Life: >40 hours Consumption: 8.3 mA DC (approximately) |
| Dimensions | Main instrument: 10.6 x 4.2 x 2" (269 x 106 x 51 mm) Vane inner diameter: 3.94" (100 mm) |
| Weight | 1.6 lbs (725 g) including battery and probe |
| Air Velocity | |
| m/s | Range: 0.2 to 30 m/s Resolution: 0.01 m/s Accuracy: ±(1.5% rdg + 0.3 m/s) |
| ft/min | Range: 40 to 5900 ft/min Resolution: 1 ft/min Accuracy: ±(1.5% rdg + 59 ft/min) |
| Air Flow (Volume) | |
| CMM | Range: 0 to 99999 m3/min Resolution: 0.1 up to 9999.9 then 1.0 Area range: 0 to 99999 cm2 |
| CFM | Range: 0 to 99999 ft3/min Resolution: 0.1 up to 9999.9 then 1.0 Area range: 0 to 99999 in2 |
| Air Temperature | |
| °F/C | Range: -4 to 140°F (-20 to 60°C) Resolution: 0.1°F/C Accuracy: ±1.1°F (-5 to 122°F), ±2.2°F (123 to 140°F); ±0.6°C (-20 to 50°C), ±1.2°C (51 to 60°C) |
| General Specifications | |
| Circuit | Custom LSI microprocessor |
| Display | Dual function 0.5" (13 mm) 4-digit LCD |
| Sampling Rate | 1 reading per second approximately |
| Sensors | Air velocity/flow: Conventional angled vane arms with low-friction ball bearing Temperature: NTC-type precision thermistor |
| Automatic Power-Off | Auto shut off after 20 minutes to preserve battery life (sleep mode) |
| Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: 14 to 122°F (-10 to 50°C) |
| Humidity | Operating <80% RH Storage: <90% RH |
| Operating Altitude | 7000' (2000 m) maximum |
| Battery | Type: 4 x AAA 1.5 V batteries Life: >40 hours Consumption: 8.3 mA DC (approximately) |
| Dimensions | Main instrument: 10.6 x 4.2 x 2" (269 x 106 x 51 mm) Vane inner diameter: 3.94" (100 mm) |
| Weight | 1.6 lbs (725 g) including battery and probe |