A complete solution kit with USB datalogger for the Restoration Contractor.
A complete solution kit with USB datalogger for the Restoration Contractor.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Extech MO290-RK-i7 - Water Restoration Contractor Kit
Water Restoration Contractor Kit
A complete solution for the Restoration Contractor
Thermal imaging camera quickly locates areas of moisture in building materials.Use combination moisture meter/thermal hygrometer to capture all ambient conditions as well as moisture levels in one meter. Includes essential probes to measure moisture levels under baseboards, in between walls, and in hard wood and plywood subfloors. Use USB Humidity/Temperature datalogger for GPP calculations
Features
| Temperature range | 32°F to 482°F (0°C to 250°C) |
| Image Storage | 5000 Images (microSD card memory) |
| Emissivity | Emissivity Table; 0.1 to 1.0 adjustable |
| Field of view/min focus distance | 17° X 17°/0.6m (2 ft.) |
| Focus | Focus free |
| Thermal sensitivity (N.E.T.D) | <0.1°C at 25°C |
| Detector Type | Focal plane array (FPA) uncooled microbolometer; 120 X 120 pixels |
| Spectral range | 7.5 to 13µm |
| Display | 2.8" color LCD |
| Image Controls | Palettes (Iron Rainbow and Black/White) |
| Set-up controls | Date/time °C/°F 21 languages |
| Measurement modes | Spot (with correction for emissivity and reflected temperature) Area (Max/Min) Isotherm (above/below selected temperature interval) |
| Battery Type | Li-lon |
| Battery operating time | >4 hours Display shows battery status |
| Charging system | In camera AC adapter; 3 hours to 90% capacity |
| AC operation | AC adaptor 90-260VAC 50/60Hz |
| Adaptor Voltage | 5 VDC output to camera |
| Operating temperature range | 32°F to 122°F (0°C to 50°C) |
| Storage temperature range | -40°F to 158°F (-40°C to 70°C) |
| Humidity | Operating and storage 20% to 80% non-condensing IEC 359 |
| Shock | 25G IEC 68-2-29 |
| Vibration | 2G IEC 68-2-6 |
| Dimensions/Weight | 8.8x3.1x3.3" (223x79x83mm)/<12oz. (340g) including battery |
| Sensor Type | Non-Penetrating |
| Pinless Moisture | 0 to 99.9 (Relative) |
| Pinless Depth | up to 0.75" (19mm) |
| Pin-type Moisture (probe included) | 0 to 99.9% |
| Max Resolution | 0.1 0.1°F/°C |
| Humidity | 0 to 100%RH |
| Temperature (Air) | -20 to 170°F (-29 to 77°C) |
| Temperature (IR) | -4 to 392°F (-20 to 200°C) |
| Vapor Pressure | 0 to 20.0kPA |
| Dew Point | -22 to 199°F (-30 to 100°C) |
| Mixing ratio | 0 to 999GPP (0 to 160g/kg) |
| Field of View | 8:1 Distance to Target ratio |
| Emissivity | 0.95 fixed |
| Dimensions | 6.5x2.8x1.5” (165x70x38) |
| Weight | 7.4oz (210g) |
| Temperature | -40 to 158°F |
| Humidity | 0 to 100% ±3%RH |
| Datalogging interval | 1 second to 24 hours |
| Memory | Temperature- 16000 points; Relative Humidity- 16000 points |
| Dimensions | 5.1 x 1.1 x 0.98" (130 x 30 x 25mm) |
| Weight | 1oz (20g) |
| Temperature range | 32°F to 482°F (0°C to 250°C) |
| Image Storage | 5000 Images (microSD card memory) |
| Emissivity | Emissivity Table; 0.1 to 1.0 adjustable |
| Field of view/min focus distance | 17° X 17°/0.6m (2 ft.) |
| Focus | Focus free |
| Thermal sensitivity (N.E.T.D) | <0.1°C at 25°C |
| Detector Type | Focal plane array (FPA) uncooled microbolometer; 120 X 120 pixels |
| Spectral range | 7.5 to 13µm |
| Display | 2.8" color LCD |
| Image Controls | Palettes (Iron Rainbow and Black/White) |
| Set-up controls | Date/time °C/°F 21 languages |
| Measurement modes | Spot (with correction for emissivity and reflected temperature) Area (Max/Min) Isotherm (above/below selected temperature interval) |
| Battery Type | Li-lon |
| Battery operating time | >4 hours Display shows battery status |
| Charging system | In camera AC adapter; 3 hours to 90% capacity |
| AC operation | AC adaptor 90-260VAC 50/60Hz |
| Adaptor Voltage | 5 VDC output to camera |
| Operating temperature range | 32°F to 122°F (0°C to 50°C) |
| Storage temperature range | -40°F to 158°F (-40°C to 70°C) |
| Humidity | Operating and storage 20% to 80% non-condensing IEC 359 |
| Shock | 25G IEC 68-2-29 |
| Vibration | 2G IEC 68-2-6 |
| Dimensions/Weight | 8.8x3.1x3.3" (223x79x83mm)/<12oz. (340g) including battery |
| Sensor Type | Non-Penetrating |
| Pinless Moisture | 0 to 99.9 (Relative) |
| Pinless Depth | up to 0.75" (19mm) |
| Pin-type Moisture (probe included) | 0 to 99.9% |
| Max Resolution | 0.1 0.1°F/°C |
| Humidity | 0 to 100%RH |
| Temperature (Air) | -20 to 170°F (-29 to 77°C) |
| Temperature (IR) | -4 to 392°F (-20 to 200°C) |
| Vapor Pressure | 0 to 20.0kPA |
| Dew Point | -22 to 199°F (-30 to 100°C) |
| Mixing ratio | 0 to 999GPP (0 to 160g/kg) |
| Field of View | 8:1 Distance to Target ratio |
| Emissivity | 0.95 fixed |
| Dimensions | 6.5x2.8x1.5” (165x70x38) |
| Weight | 7.4oz (210g) |
| Temperature | -40 to 158°F |
| Humidity | 0 to 100% ±3%RH |
| Datalogging interval | 1 second to 24 hours |
| Memory | Temperature- 16000 points; Relative Humidity- 16000 points |
| Dimensions | 5.1 x 1.1 x 0.98" (130 x 30 x 25mm) |
| Weight | 1oz (20g) |