SC480 is a mid-sized True RMS Wireless Power Clamp Meter with direct integration with the Job Link System App and packed with all the essential features service technician need to install, service, and troubleshoot any HVAC/R system. The SC480 clamp meter is ideal for obtaining electrical measurements on mini splits and includes Molex tips for hard-to-read circuitry. A low pass filter provides reliable voltage readings on variable frequency drives (VFDs) as well as tests three-phase power lines with two leads and maintains wireless connection directly to a mobile device at 1000' (305 m). This multimeter SC480 has a safety rating of CAT IV at 600 V and CAT III at 1000 V.
SC480 is a mid-sized True RMS Wireless Power Clamp Meter with direct integration with the Job Link System App and packed with all the essential features service technician need to install, service, and troubleshoot any HVAC/R system. The SC480 clamp meter is ideal for obtaining electrical measurements on mini splits and includes Molex tips for hard-to-read circuitry. A low pass filter provides reliable voltage readings on variable frequency drives (VFDs) as well as tests three-phase power lines with two leads and maintains wireless connection directly to a mobile device at 1000' (305 m). This multimeter SC480 has a safety rating of CAT IV at 600 V and CAT III at 1000 V.
The SC480 TRMS clamp meter is great for troubleshooting mini-split systems. By utilizing the RCT2 Molex probe tips, you are able to reach those cramped mini-split connectors to measure voltage and resistance. In addition, you can measure frequency directly with the clamp jaw.
The SC480 600A clamp meter will also help determine system efficiency by directly measuring power consumption (kW) of a system. This can be helpful to provide your customers with this information and ways they can implement energy saving measures to lower their energy bills.
You can take more accurate VAC and AAC readings on variable frequency drives with the True RMS sensing technology. Measure the starting amp draw of a compressor with Inrush current mode. One of the most failure prone components in an HVACR system is the capacitor. The capacitance test allows a service technician to test questionable motor start and run capacitors to determine when a capacitor needs to be replaced.
The SC480 Fieldpiece can be attached to any metallic surface with the heavy duty magnet hanger, allowing hands free work. The big dual backlit display makes it easy to see both voltage and amperage readings at the same time. You also have the ability to take measurements more safely with one hand using the single test lead holder. One of the safety features on the SC480 meter is the high voltage warning. This includes a warning symbol on the display, an audible beep, and a red LED that will light up.
A service technician can connect directly with the Job Link app up to 1000' (305 m) to document all electrical measurements. The Fieldpiece SC480 can also be paired with the SM380V or SM480V manifolds, SRS3 wireless scale, and other Job Link Probes and accessory heads to receive and document a complete system snapshot in the app.
Features
Applications
Display | 10,000 count dual display |
Backlight | 5 minute duration with auto-off, blue color |
Overrange | "OL" or "-OL" is displayed |
Measurement rate | 3.3 times per second, nominal |
Zero | Automatic |
Operating environment | 32 to 122°F (0 to 50°C) at <70%RH |
Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80%RH (with battery removed) |
Accuracy | Stated accuracy at 73°F±9°F (23°C±5°C), <75%RH |
Temperature coefficient | 0.1 x (specified accuracy) per °C: 0 to 19°C (32 to 66°F), 28 to 50°C (82 to 122°F) |
APO (Auto Power Off) | Approximately 30 minutes |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 100 hours typical alkaline (No wireless, no backlight) |
Low battery indication | Battery icon blinks and "batt" is displayed when the battery voltage drops below the operating level |
Altitude | Up to 6562' (2000 m) |
Overload protection | 1000VDC or 750VAC rms unless otherwise stated |
Test leads | Use UL listed test leads that comply to UL61010-031 rated CATIV 600V, CATIII 1000V or above. Included test leads are gold-plated and have removable safety caps. |
Dimensions | 9.72 x 3.11 x 1.89" (247 x 79 x 48 mm) |
Weight | Approximately 12 oz (345 g) including battery |
Click on a category to view a selection of compatible accessories with the Fieldpiece SC480 Wireless True RMS Power Clamp Meter CAT IV 600V - CAT III 1000V.
Display | 10,000 count dual display |
Backlight | 5 minute duration with auto-off, blue color |
Overrange | "OL" or "-OL" is displayed |
Measurement rate | 3.3 times per second, nominal |
Zero | Automatic |
Operating environment | 32 to 122°F (0 to 50°C) at <70%RH |
Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80%RH (with battery removed) |
Accuracy | Stated accuracy at 73°F±9°F (23°C±5°C), <75%RH |
Temperature coefficient | 0.1 x (specified accuracy) per °C: 0 to 19°C (32 to 66°F), 28 to 50°C (82 to 122°F) |
APO (Auto Power Off) | Approximately 30 minutes |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 100 hours typical alkaline (No wireless, no backlight) |
Low battery indication | Battery icon blinks and "batt" is displayed when the battery voltage drops below the operating level |
Altitude | Up to 6562' (2000 m) |
Overload protection | 1000VDC or 750VAC rms unless otherwise stated |
Test leads | Use UL listed test leads that comply to UL61010-031 rated CATIV 600V, CATIII 1000V or above. Included test leads are gold-plated and have removable safety caps. |
Dimensions | 9.72 x 3.11 x 1.89" (247 x 79 x 48 mm) |
Weight | Approximately 12 oz (345 g) including battery |
Click on a category to view a selection of compatible accessories with the Fieldpiece SC480 Wireless True RMS Power Clamp Meter CAT IV 600V - CAT III 1000V.