Take accurate and repeatable measurements due to the precise laser technology on this Infrared thermometer. It features a 20:1 distance to spot ratio and a 99 data point logging. Additionally, the flashlight and large, easy-to-read backlit LCD display, which facilitates viewing in dark areas.
Take accurate and repeatable measurements due to the precise laser technology on this Infrared thermometer. It features a 20:1 distance to spot ratio and a 99 data point logging. Additionally, the flashlight and large, easy-to-read backlit LCD display, which facilitates viewing in dark areas.
Features
| Temperature Range | -22 to 1112°F (-30 to 600°C) |
| Accuracy (Calibration Geometry with Ambient Temperature 23°C ±2°C | ±1.0 °C or ±1.0% of reading, whichever is greater ±2.0°C at 14 to 32°F (-10 to 0°C) ±3.0°C at -22 to 14°F (-30 to -10°C) |
| Optical Resolution | 20:1 (calculated at 90 % energy) |
| Response Time (95%) | <500 ms (95% of reading) |
| Spectral Response | 8 to 14 microns |
| Emissivity | 0.10 to 1.00 |
| Display Resolution | 0.2°F (0.1°C) |
| Repeatability (% of Reading) | ±0.5% of reading or ±0.5°C (whichever is greater) |
| Auto Capture | Set time and interval to capture up to 99 measurements |
| Internal Memory | 99 data point logging capability |
| Flashlight | Yes |
| Power | 1 AA battery |
| Battery Life | 30 hours with laser and backlight on |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) without battery |
| Operating Humidity | Non- condensing at ≤50°F (10°C) ≤90% RH at 50 to 86°F (10 to 30°C) ≤75% RH at 86 to 104°F (30 to 40°C) ≤45% RH at 104 to 122°F (40 to 50°C) |
| Operating Altitude | 6561.7' (2000 m) above mean sea level |
| Optical Resolution | 39,370.08 (12,000 m) meters above mean sea level |
| Drop Test | 9.8' (3 m) |
| Dimensions | 6.88 x 3.34 x 295" (175 x 85 x 75 mm) |
| Weight | 0.56 lb (255 g) |
| Implement Standard | Q/ASF01 |
| Compliance | IEC 61010-1: Pollution Class 2 |
| Laser Safety | IEC 60825-1 Class 2, 650 nm, <1 mW |
| Ingress Protection Rating | IP 54 per IEC 60529 |
Click on a category to view a selection of compatible accessories with the Fluke 64 MAX Infrared (IR) Thermometer, 20:1 distance to spot ratio.
| Temperature Range | -22 to 1112°F (-30 to 600°C) |
| Accuracy (Calibration Geometry with Ambient Temperature 23°C ±2°C | ±1.0 °C or ±1.0% of reading, whichever is greater ±2.0°C at 14 to 32°F (-10 to 0°C) ±3.0°C at -22 to 14°F (-30 to -10°C) |
| Optical Resolution | 20:1 (calculated at 90 % energy) |
| Response Time (95%) | <500 ms (95% of reading) |
| Spectral Response | 8 to 14 microns |
| Emissivity | 0.10 to 1.00 |
| Display Resolution | 0.2°F (0.1°C) |
| Repeatability (% of Reading) | ±0.5% of reading or ±0.5°C (whichever is greater) |
| Auto Capture | Set time and interval to capture up to 99 measurements |
| Internal Memory | 99 data point logging capability |
| Flashlight | Yes |
| Power | 1 AA battery |
| Battery Life | 30 hours with laser and backlight on |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) without battery |
| Operating Humidity | Non- condensing at ≤50°F (10°C) ≤90% RH at 50 to 86°F (10 to 30°C) ≤75% RH at 86 to 104°F (30 to 40°C) ≤45% RH at 104 to 122°F (40 to 50°C) |
| Operating Altitude | 6561.7' (2000 m) above mean sea level |
| Optical Resolution | 39,370.08 (12,000 m) meters above mean sea level |
| Drop Test | 9.8' (3 m) |
| Dimensions | 6.88 x 3.34 x 295" (175 x 85 x 75 mm) |
| Weight | 0.56 lb (255 g) |
| Implement Standard | Q/ASF01 |
| Compliance | IEC 61010-1: Pollution Class 2 |
| Laser Safety | IEC 60825-1 Class 2, 650 nm, <1 mW |
| Ingress Protection Rating | IP 54 per IEC 60529 |
Click on a category to view a selection of compatible accessories with the Fluke 64 MAX Infrared (IR) Thermometer, 20:1 distance to spot ratio.