The Fluke 773 milliamp clamp meter is accurate, versatile, and highly portable. It saves time and money by measuring 4 to 20 mA signals five times faster than traditional multimeters, without breaking the loop. It calculates the current process through a section.
The Fluke 773 milliamp clamp meter is accurate, versatile, and highly portable. It saves time and money by measuring 4 to 20 mA signals five times faster than traditional multimeters, without breaking the loop. It calculates the current process through a section.
The 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems. This clamp meter sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1 to 5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.
Advanced loop troubleshooting with the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing the transmitter. You can also apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators. Moreover, it offers mA or voltage output linear ramp or 25% step output.
Features
Applications
mA Measure | Yes |
Jaw | Yes |
mA Measure | Yes |
In Circuit | Yes |
mA Source | Yes |
mA Sim | Yes |
Loop Power | Yes |
24 V | Yes |
DC V Source | Yes |
0 to 10 V | Yes |
DC V Measure | Yes |
0 to 30 V | Yes |
Scaled mA Output to mA Input | Yes |
mA In/Out | Yes |
mA measurement | Resolution: 0 to 20.99 mA Accuracy: 0.2% + 5 counts Notes: Measured by clamp Resolution: 21.0 mA to 100.0 mA Accuracy: 1% + 5 counts Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Measured in series with test jacks |
mA source | Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Maximum mA drive: 24 mA into 1000 ohms |
mA simulate | Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Maximum voltage 50 V DC |
Voltage source | Resolution: 0 to 10.00 V DC Accuracy: 0.2% + 2 counts Notes: 2 mA maximum drive current |
Voltage measure | Resolution: 0 to 30.00 V DC Accuracy: 0.2% + 2 counts |
Influence of earth’s field | <0.12 mA |
Vibration requirements | Random 2 g, 5 Hz to 500 Hz |
Drop test | Passes 1 meter drop test (except the jaw) |
EMI, RFI, EMC | Meets applicable requirements in EN61326-1 Note: For current measurement w/jaw, add 1 mA to specification for EMC field strengths of 1 V/m up to 3 V/m |
IP rating | IP 40 |
Temperature coefficients | 0.1(/°C x specified accuracy for temperature < 64.4°F (18°C) or > 82.4°F (28°C)) |
Environmental Conditions | Operating temperature: 14 to 122 °F (-10 to 50 °C) Storage temperature: -13 to 140 °F (-25 to 60 °C) Operating humidity: < 90% @ < 86°F (30°C); < 75% @ 86 to 131 °F (30 to 55°C) Operating altitude: 0 to 2000 m |
Warranty | Three-years, one-year on mA clamp assembly and cable |
Power | Battery: 4 x 1.5 V, Alkaline, IEC LR6 Battery life: 12 hours @ 12 mA source into 500 ohms |
Dimensions | 1.625 x 3 x 9.75" (41.3 x 76 x 248 mm) |
Weight | 14 oz (415 g) |
Click on a category to view a selection of compatible accessories with the Fluke 773 CAL Milliamp Process Clamp Meter with calibration certificate.
mA Measure | Yes |
Jaw | Yes |
mA Measure | Yes |
In Circuit | Yes |
mA Source | Yes |
mA Sim | Yes |
Loop Power | Yes |
24 V | Yes |
DC V Source | Yes |
0 to 10 V | Yes |
DC V Measure | Yes |
0 to 30 V | Yes |
Scaled mA Output to mA Input | Yes |
mA In/Out | Yes |
mA measurement | Resolution: 0 to 20.99 mA Accuracy: 0.2% + 5 counts Notes: Measured by clamp Resolution: 21.0 mA to 100.0 mA Accuracy: 1% + 5 counts Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Measured in series with test jacks |
mA source | Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Maximum mA drive: 24 mA into 1000 ohms |
mA simulate | Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Maximum voltage 50 V DC |
Voltage source | Resolution: 0 to 10.00 V DC Accuracy: 0.2% + 2 counts Notes: 2 mA maximum drive current |
Voltage measure | Resolution: 0 to 30.00 V DC Accuracy: 0.2% + 2 counts |
Influence of earth’s field | <0.12 mA |
Vibration requirements | Random 2 g, 5 Hz to 500 Hz |
Drop test | Passes 1 meter drop test (except the jaw) |
EMI, RFI, EMC | Meets applicable requirements in EN61326-1 Note: For current measurement w/jaw, add 1 mA to specification for EMC field strengths of 1 V/m up to 3 V/m |
IP rating | IP 40 |
Temperature coefficients | 0.1(/°C x specified accuracy for temperature < 64.4°F (18°C) or > 82.4°F (28°C)) |
Environmental Conditions | Operating temperature: 14 to 122 °F (-10 to 50 °C) Storage temperature: -13 to 140 °F (-25 to 60 °C) Operating humidity: < 90% @ < 86°F (30°C); < 75% @ 86 to 131 °F (30 to 55°C) Operating altitude: 0 to 2000 m |
Warranty | Three-years, one-year on mA clamp assembly and cable |
Power | Battery: 4 x 1.5 V, Alkaline, IEC LR6 Battery life: 12 hours @ 12 mA source into 500 ohms |
Dimensions | 1.625 x 3 x 9.75" (41.3 x 76 x 248 mm) |
Weight | 14 oz (415 g) |
Click on a category to view a selection of compatible accessories with the Fluke 773 CAL Milliamp Process Clamp Meter with calibration certificate.