CertiFiber Max single-mode multi-fiber optical loss test set including two Versiv 2 mainframes with Wi-Fi, two CertiFiber Max modules, required accessories for certifying length, loss, and polarity of pinned MPO 12 cables and two FiberInspector Ultra inspection cameras. Maximize your multi-fiber certification efficiency with the CertiFiber Max OLTS. Measure loss, length, and polarity of up to 24 fibers in seconds. Field-replaceable UniPort adapters connect directly to MPO, MMC, pinned and unpinned configurations, and more, giving you maximum flexibility.
CertiFiber Max single-mode multi-fiber optical loss test set including two Versiv 2 mainframes with Wi-Fi, two CertiFiber Max modules, required accessories for certifying length, loss, and polarity of pinned MPO 12 cables and two FiberInspector Ultra inspection cameras. Maximize your multi-fiber certification efficiency with the CertiFiber Max OLTS. Measure loss, length, and polarity of up to 24 fibers in seconds. Field-replaceable UniPort adapters connect directly to MPO, MMC, pinned and unpinned configurations, and more, giving you maximum flexibility.
Maximum fibers. Maximum efficiency. Maximum advantage.
Features
Set up your projects right the first time with the Versiv™ ProjX management system, or remotely with LinkWare™ Live. Minimize measurement uncertainty with 1-jumper reference setting and an integrated timer that tracks time since the reference was set and a counter for the number of times a Test Reference cord has been used. Troubleshoot fast with a built-in multi-fiber VFL, duplex power meter, and optional end face inspection.
With more than 10,000 Certified Cabling Test Technicians (CCTT) in the field, the CertiFiber Max OLTS is already part of a familiar, trusted tool set that’s built Fluke rugged, supported by Fluke expertise, and backed by gold-standard Fluke service and experience.
The CertiFiber Max OLTS offers a native connection to MPO 12 pinned cables as standard and optionally supports MPO 12/16/24 and MMC 16/24 pinned or unpinned cables without complicated breakout cables or adjusting pin configurations. Changing configurations is as simple as swapping the field-changeable UniPort™ adapters and using the appropriate test reference cords. UniPort adapters allow connection of any MPO 12/16/24 and MMC 16/24 pinned or unpinned cable to the test port and provide protection for the test port. TRC cords are available to support these same configurations.
Designed for Maximum Accuracy
With decades of experience designing the world’s most accurate calibration equipment, we’ve built the CertiFiber Max OLTS to meet the exacting measurement requirements of today’s highest-performance fiber networks. But even the most accurate tester will deliver poor results unless it’s used properly. Manufacturers and standards recommend onejumper reference setting for the most accurate measurements, and the CertiFiber Max OLTS offers that for every cable configuration.
To reduce errors in the field, the tester includes a “Wizard” that takes the technician stepby-step through the crucial referencing process. Mistakes made in reference setting can result in the loss of an entire day’s work. The Wizard specifies the exact accessories needed, monitors the user’s process through the steps, verifies whether measurements are within acceptable limits, allows cleaning of the end faces, and stores the critical reference values for reporting. UniPort adapters are color-coded to match the Wizard and Test Reference cords, which feature reference-quality fiber and connectors.
Results of the reference setting (including measured power and loss of the verification cords for each fiber tested) are stored and presented with project test reports, providing proof the process was done correctly.
Simple Results with Details
Designers can set limits using the built-in calculator — simply choose a standard, enter the number and type of connectors in the link, and The CertiFiber Max OLTS determines the length-based loss limits for the test. Or choose a specific application or enter custom limits based on the job specification. Either way, the technician sees a simple PASS or FAIL for each link tested, along with the worst-case loss margin, length, and polarity. Touching the screen shows loss on each fiber, and a polarity diagram.
Efficiency and Ease of Use
In one second, The CertiFiber Max OLTS can test and store results for a cable with up to 24 fibers. But Versiv cuts the overhead around the test time as well. Its ProjX management system means that the tester can be set up ahead of time with only the cable types, limits, and identifiers for the job — which reduces confusion and mistakes. Versiv uses a tone to indicate when the far-end tester is connected and can be set up to start tests, save results, and increment to the next cable identifier automatically, saving even more time on large projects.
Counter and Timer
To maximize measurement certainty, some customers require limits on the length of time a specific reference setting can be used or how many measurements can be made with the same set of test reference cords. The CertiFiber Max OLTS includes an optional built-in timer that tracks how long it’s been since the reference was set, and the ability to set a limit so the user is warned before and after that time has been exceeded. In a similar fashion, an optional counter tracks how many tests have been performed with a specific set of TRCs, and limits can be set so that the user is warned when that limit is about to be and is exceeded.
Integrated Visual Fault Locator and Duplex Power Meter
The CertiFiber Max OLTS is not only an efficient testing machine, but it can help troubleshoot as well. A Visual Fault Locator (VFL) can illuminate any fiber configuration up to 24 fibers simultaneously for troubleshooting. Integrated into the source port (in both the main and remote) so that the VFL can be turned on to troubleshoot the cable by techs at both ends, without disconnecting it, which speeds troubleshooting. A duplex power meter port with adapters for SC or LC connectors can be used to measure power from cassettes or duplex fibers.
Integrated Inspection
Fiber optic connector end-face contamination is a leading cause of fiber failures. Fiber loss testing can expose this problem, but dirty connections make fiber testing time consuming and inaccurate. Dirt can be an issue before, during, or after fiber optic certification testing, and can migrate from one fiber optic connector end-face to another upon mating, so both ends of any connection must always be inspected and cleaned if necessary.
The CertiFiber Max OLTS provides double-ended fiber optic inspection capability through the use of two Versiv Main units along with two FI-3000 FiberInspector™ Ultra cameras. The double-ended fiber optic inspection capability allows inspection and automated PASS/FAIL results for MPO or MMC (as well as single-fiber) end faces at both ends of the fiber link in seconds. Store inspection images and PASS/FAIL results along with the loss, length, and polarity data in a single report. Fluke Networks also provides a wide array of tips for inspecting single fibers and cleaning supplies for multi-, duplex- and single fibers.
LinkWare Live
LinkWare Live is Software as a Service from Fluke Networks for cabling professionals managing multiple projects. It quickly, easily, and affordably provides unmatched job visibility and superior project control from anywhere, at any time.
LinkWare Live increases productivity because you don’t need to recall testers from the field just to download test results. Just upload the results from the tester to LinkWare Live from the jobsite so you can finish sooner, get home sooner, and get paid faster. LinkWare Live reduces reporting time by automatically consolidating all results into the correct job, and it cuts rework by reducing the chance of losing test results if something happens to the testers or memory cards. LinkWare Live provides instant access to results for faster troubleshooting and real time visibility into project status from any location. It fully integrates with LinkWare PC for fast reporting.
LinkWare Live also reduces errors by allowing project managers to set up testers remotely through smartphones, tablets, or PCs. Every aspect of the project, including cable types, limits, and cable identifiers, can be downloaded, eliminating the chance for operator error. And if someone changes that setup, LinkWare Live will let you know.
LinkWare PC Management Software
With LinkWare PC management software, CertiFiber Max users can easily access the ProjX management system data, generate reports, and upgrade the software in their testers. Project managers have full capabilities to monitor workflow and consolidate test results.
LinkWare PC provides automated statistical reports. That moves you above and beyond page-per-link reporting to see your entire cabling infrastructure in one summary. It analyzes and transforms test results into charts to reveal cabling plant performance. It even summarizes your entire cabling infrastructure in a compact, graphical format, so it's easy to verify margins and spot anomalies. Previous versions of LinkWare PC are backward compatible with new versions, so you can stay current and integrate tests from different testers into a single test report.
Combine the CertiFiber Max OLTS Tier 1 (loss, length, and polarity) and fiber inspection images in a single report while managing multiple jobs simultaneously. Add a company logo to give your report the finishing touch before offering it to your customer for system acceptance. The advantage of the system is that no matter which Fluke Networks cabling certification tester you use, LinkWare PC reports it all.
| Power Meter Specifications | |
| Included UniPort Adapter | Non-contact MPO 12-fiber pinned |
| Optional Uniport Adapters | MPO 12/16/24 and MMC 16/24 pinned or unpinned |
| Detector Type | 16 large core fibers coupled to 16 InGaAs photodiodes |
| Supported Fiber Type | Single-mode 9/125 µm |
| Calibrated Wavelengths | 1310 nm, 1550 nm |
| Power Measurement Linearity | ±0.10 dB |
| Power Measurement Repeatability | ±0.02 dB |
| Power Measurement Reproducibility | ±0.1 dB |
| Power Measurement Uniformity | ±0.1dB |
| Loss Measurement Budget | 10 dB |
| Re-calibration Period | 1 year |
| Optical Sources Specifications | |
| Output port | MPO 16 pinned |
| Fiber Type | 9/125 µm |
| Central Wavelengths (nm) | 1310 ± 20 1550 ± 20 |
| Emitter Type | Fabry-Perot laser |
| Spectral Width (nm) | ≤5 (1310 nm and 1550 nm) |
| Output Power (dBm) Nominal | ≥ -12 dBm |
| Power Stability (dB) | ± 0.10 |
| Launch Condition | Not applicable |
| Length Measurement Range | Up to 25 km |
| Length Measurement Uncertainty | ±1 meter + 1% of length |
| Visaul Fault Indicator (Source Port) | |
| Connector | MPO 16, pinned (when testing, this port will be connected to a Test Reference Cord which is available in MPO 12/16/24 and MMC 16/24 pinned and unpinned). |
| Total Output Power | >-5 dBm <0 dBm, continuous wave, at the 9/125 µm patch cord for single-mode source |
| Operating Wavelength | 635 nm nominal |
| Output Modes | Continuous, pulsed blink frequency (2 Hz to 3 Hz) |
| Laser Safety | Class II CDRH |
| Optical Power Meter - Duplex Port | |
| Input Connector | Cylindrical ferrule duplex connectors (only one ferrule is measured at a time) |
| Default Port Adapter | LC Duplex |
| Optional Port Adapters | SC Duplex |
| Detector Type | 1 mm InGaAs photodiode accommodates one fiber at a time |
| Supported Fiber Type | Single-mode 9/125 µm |
| Calibrated Wavelengths | 1310 nm, 1550 nm |
| Power Measurement Range | +5 dBm to -45 dBm |
| Power Measurement Uncertainty | < ± 0.35 dB |
| Power Measurement Linearity | ±0.10 dB |
| Power Measurement Repeatability | ±0.02 dB |
| Power Measurement Reproducibility | ±0.05 dB |
| Optical Connector Interface | Accepts simplex LC or SC non-angled (UPC) and (APC) end face |
| Re-calibration Period | 1 year |
| Environmental Specifications | |
| Operating Temperature | -10°C to 45°C |
| Storage Temperature | -10°C to 60°C |
| Operating Relative Humidity | 0 to 95 % non-condensing, 0°C to 35°C 0 to 70 %, 35°C to 45°C |
| Vibration | Random, 2 g, 5 Hz to 500 Hz |
| Shock | 1-meter drop test |
| Safety | IEC 61010-1 |
| Pollution Degree | 2 |
| Altitude | Operating: 4 km Storage: 12 km |
| EMC | IEC 61326-1 |
Click on a category to view a selection of compatible accessories with the Fluke Networks CFM-100SI CertiFiber Max Single-Mode OLTS with two Versiv 2 mains, two inspection cameras, Wi-Fi, pinned MPO 12.
| Power Meter Specifications | |
| Included UniPort Adapter | Non-contact MPO 12-fiber pinned |
| Optional Uniport Adapters | MPO 12/16/24 and MMC 16/24 pinned or unpinned |
| Detector Type | 16 large core fibers coupled to 16 InGaAs photodiodes |
| Supported Fiber Type | Single-mode 9/125 µm |
| Calibrated Wavelengths | 1310 nm, 1550 nm |
| Power Measurement Linearity | ±0.10 dB |
| Power Measurement Repeatability | ±0.02 dB |
| Power Measurement Reproducibility | ±0.1 dB |
| Power Measurement Uniformity | ±0.1dB |
| Loss Measurement Budget | 10 dB |
| Re-calibration Period | 1 year |
| Optical Sources Specifications | |
| Output port | MPO 16 pinned |
| Fiber Type | 9/125 µm |
| Central Wavelengths (nm) | 1310 ± 20 1550 ± 20 |
| Emitter Type | Fabry-Perot laser |
| Spectral Width (nm) | ≤5 (1310 nm and 1550 nm) |
| Output Power (dBm) Nominal | ≥ -12 dBm |
| Power Stability (dB) | ± 0.10 |
| Launch Condition | Not applicable |
| Length Measurement Range | Up to 25 km |
| Length Measurement Uncertainty | ±1 meter + 1% of length |
| Visaul Fault Indicator (Source Port) | |
| Connector | MPO 16, pinned (when testing, this port will be connected to a Test Reference Cord which is available in MPO 12/16/24 and MMC 16/24 pinned and unpinned). |
| Total Output Power | >-5 dBm <0 dBm, continuous wave, at the 9/125 µm patch cord for single-mode source |
| Operating Wavelength | 635 nm nominal |
| Output Modes | Continuous, pulsed blink frequency (2 Hz to 3 Hz) |
| Laser Safety | Class II CDRH |
| Optical Power Meter - Duplex Port | |
| Input Connector | Cylindrical ferrule duplex connectors (only one ferrule is measured at a time) |
| Default Port Adapter | LC Duplex |
| Optional Port Adapters | SC Duplex |
| Detector Type | 1 mm InGaAs photodiode accommodates one fiber at a time |
| Supported Fiber Type | Single-mode 9/125 µm |
| Calibrated Wavelengths | 1310 nm, 1550 nm |
| Power Measurement Range | +5 dBm to -45 dBm |
| Power Measurement Uncertainty | < ± 0.35 dB |
| Power Measurement Linearity | ±0.10 dB |
| Power Measurement Repeatability | ±0.02 dB |
| Power Measurement Reproducibility | ±0.05 dB |
| Optical Connector Interface | Accepts simplex LC or SC non-angled (UPC) and (APC) end face |
| Re-calibration Period | 1 year |
| Environmental Specifications | |
| Operating Temperature | -10°C to 45°C |
| Storage Temperature | -10°C to 60°C |
| Operating Relative Humidity | 0 to 95 % non-condensing, 0°C to 35°C 0 to 70 %, 35°C to 45°C |
| Vibration | Random, 2 g, 5 Hz to 500 Hz |
| Shock | 1-meter drop test |
| Safety | IEC 61010-1 |
| Pollution Degree | 2 |
| Altitude | Operating: 4 km Storage: 12 km |
| EMC | IEC 61326-1 |
Click on a category to view a selection of compatible accessories with the Fluke Networks CFM-100SI CertiFiber Max Single-Mode OLTS with two Versiv 2 mains, two inspection cameras, Wi-Fi, pinned MPO 12.