Fluke Networks LIQ-100 Cable and Network Tester, 10 GB, 1000'

Model: LIQ-100 | UPC: 754082152163

Fluke Networks LIQ-100 Cable and Network Tester, 10 GB, 1000'

Model: LIQ-100 | UPC: 754082152163

Measure cable lengths up to 1000' (305 m) and provides connected switch information for troubleshooting active networks with this cable and network tester. Frequency-based measurements are used to validate network capacity up to 10 Gig and also provides distance to fault information with graphical wire map of cable under tests.

Measure cable lengths up to 1000' (305 m) and provides connected switch information for troubleshooting active networks with this cable and network tester. Frequency-based measurements are used to validate network capacity up to 10 Gig and also provides distance to fault information with graphical wire map of cable under tests.

Sale Price $2661.04 USD
Regular Price $2956.71 USD
Availability 1 to 2 Weeks
Quantity

Fluke Networks LIQ-100 Offers

Trusted for cable testing and provides all network testing needs, this cable and network tester is a handheld instrument designed for professionals to use in testing twisted pair cables, network connectivity, and PoE. In addition, this meter provides a solution for network connectivity problems and verifies cable performance up to 10 Gb/s. Performs nearest switch diagnostics to identify key network issues and validate switch configuration.

Features

  • Measure network capacity up to 10 Gig via frequency based measurements
  • Troubleshoot active networks by providing connected switch information (Switch Name, Port Number, and VLAN info)
  • Test connectivity to TCP/IP network through IP configuration and ping
  • Verify Gateway and DNS server responsiveness and availability
  • Install and troubleshoot PoE devices via Switch Negotiation and PoE Load test
  • Graphical wiremap and length test to identify common faults that occur with cabling installation
  • Document work through LinkWare PC reporting
  • Supports Industrial Ethernet (EtherNet/IP, PROFINET, EtherCAT, and others)

Fluke Networks LIQ-100 Specifications

Cable Test
Test Port Shielded 8-pin modular jack accepts 8-pin modular (RJ45) plugs
Commissioning Autotests 10GBASE-T, 5GBASE-T, 2.5GBASE-T, 1000BASE-T, 100BASE-TX, 10BASE-T, Wire map Only
Test Speed: 6 seconds for lengths <229.6' (70 m)
Cable Types Balanced twisted-pair cabling
Unshielded twisted-pair
Screened twisted-pair
2-pair and/or 4-pair
Wire Map-Only Tests Document wire map
Length of each pair
Diagnose split pairs
User selectable T568A or T568B
User selectable crossover settings (Straight through, Half-crossover, Full-crossover)
Test speed: 1 second for lengths <393.7' (120 m)
Nominal Velocity of Propagation (NVP) User settable
Length (Maximum) 1000' (305 m)
Remote ID Locators Use remote ID terminations to identify up to 7 unique ports or office outlets
Active Network Diagnostics
Diagnostic Protocols Link Layer Discovery Protocol (LLDP)
Cisco Discovery Protocol (CDP)
Fast Link Pulses (FLP)
Internet Control Messaging Protocol (ICMP)
Dynamic Host Configuration Protocol (DHCP)
IP Address setup: LinkIQ address, DNS Server, Gateway for IPv4 or v6 either manually or via DHCP
Ping test results: Four response time results for target, DNS Server(s), Gateway, plus average and number lost
Nearest Device Diagnostics (If Available Through Diagnostic Protocols) Switch Name/IP + MAC Address
Port Number
VLAN Name
Advertised Data Rates
Advertised Duplex
Power Over Ethernet Compatibility Ethernet Alliance Certified to IEEE 802.3af/at/bt
Hardware negotiation with signature resistance
Software negotiation with LLDP/CDP
Power Over Ethernet Diagnostics Advertised Power Class (0-8)
Advertised Available Power
Powered Pairs
Diagnostics for both Single and Dual signatures
Power Over Ethernet Measurements Loaded Voltage (V)
Loaded Power (W)
Port Blink Blink the light of the connected port
Click here for complete specifications on the Fluke Networks LIQ-100

What's included with the Fluke Networks LIQ-100

  • LinkIQ with Remote IDs
  • RJ45-RJ45 Patch Cord
  • AC Charger
  • RJ45/11 Universal Coupler
  • Carrying Case

Click on a category to view a selection of compatible accessories with the Fluke Networks LIQ-100 Cable and Network Tester, 10 GB, 1000'.

Fluke Networks REMOTEID-1/Wiremapper for LinkIQ REMOTEID-1
Use the remote IDs for ethernet outlet identification and analyze each wire's length, pairing, and cable performance up to 10Gb/s for in-depth and reliable cable testing.




Fluke Networks REMOTEID-KIT Remote ID Kit for the LinkIQ and Microscanner PoE REMOTEID-KIT
Especially useful for identifying ethernet outlets, unique ports, or office outlets, these remote ID locators analyze wire length, pairing, and cable performance up to 10Gb/s for in-depth, reliable cable testing. Furthermore, this kit has six remote IDs to identify multiple wire map faults simultaneously.




Fluke Networks MS-IE-ADAPTER SET Industrial Ethernet Adapter Set MS-IE-ADAPTER SET
Use the Industrial Ethernet Remote Adapter to create a complete wire map of the cable pairs and identify miswired and split pairs on RJ45, M12X, M12D, and M8D terminated cables. Compatible with MicroScanner2, MicroScanner PoE, and LinkIQ, the Industrial Ethernet Adapter is versatile and reliable.




Ask a question about Fluke Networks LIQ-100 Cable and Network Tester, 10 GB, 1000'

Customer Reviews for the Fluke Networks LIQ-100

Fluke Networks LIQ-100 Offers

Trusted for cable testing and provides all network testing needs, this cable and network tester is a handheld instrument designed for professionals to use in testing twisted pair cables, network connectivity, and PoE. In addition, this meter provides a solution for network connectivity problems and verifies cable performance up to 10 Gb/s. Performs nearest switch diagnostics to identify key network issues and validate switch configuration.

Features

  • Measure network capacity up to 10 Gig via frequency based measurements
  • Troubleshoot active networks by providing connected switch information (Switch Name, Port Number, and VLAN info)
  • Test connectivity to TCP/IP network through IP configuration and ping
  • Verify Gateway and DNS server responsiveness and availability
  • Install and troubleshoot PoE devices via Switch Negotiation and PoE Load test
  • Graphical wiremap and length test to identify common faults that occur with cabling installation
  • Document work through LinkWare PC reporting
  • Supports Industrial Ethernet (EtherNet/IP, PROFINET, EtherCAT, and others)

Fluke Networks LIQ-100 Specifications

Cable Test
Test Port Shielded 8-pin modular jack accepts 8-pin modular (RJ45) plugs
Commissioning Autotests 10GBASE-T, 5GBASE-T, 2.5GBASE-T, 1000BASE-T, 100BASE-TX, 10BASE-T, Wire map Only
Test Speed: 6 seconds for lengths <229.6' (70 m)
Cable Types Balanced twisted-pair cabling
Unshielded twisted-pair
Screened twisted-pair
2-pair and/or 4-pair
Wire Map-Only Tests Document wire map
Length of each pair
Diagnose split pairs
User selectable T568A or T568B
User selectable crossover settings (Straight through, Half-crossover, Full-crossover)
Test speed: 1 second for lengths <393.7' (120 m)
Nominal Velocity of Propagation (NVP) User settable
Length (Maximum) 1000' (305 m)
Remote ID Locators Use remote ID terminations to identify up to 7 unique ports or office outlets
Active Network Diagnostics
Diagnostic Protocols Link Layer Discovery Protocol (LLDP)
Cisco Discovery Protocol (CDP)
Fast Link Pulses (FLP)
Internet Control Messaging Protocol (ICMP)
Dynamic Host Configuration Protocol (DHCP)
IP Address setup: LinkIQ address, DNS Server, Gateway for IPv4 or v6 either manually or via DHCP
Ping test results: Four response time results for target, DNS Server(s), Gateway, plus average and number lost
Nearest Device Diagnostics (If Available Through Diagnostic Protocols) Switch Name/IP + MAC Address
Port Number
VLAN Name
Advertised Data Rates
Advertised Duplex
Power Over Ethernet Compatibility Ethernet Alliance Certified to IEEE 802.3af/at/bt
Hardware negotiation with signature resistance
Software negotiation with LLDP/CDP
Power Over Ethernet Diagnostics Advertised Power Class (0-8)
Advertised Available Power
Powered Pairs
Diagnostics for both Single and Dual signatures
Power Over Ethernet Measurements Loaded Voltage (V)
Loaded Power (W)
Port Blink Blink the light of the connected port
Click here for complete specifications on the Fluke Networks LIQ-100

What's included with the Fluke Networks LIQ-100

  • LinkIQ with Remote IDs
  • RJ45-RJ45 Patch Cord
  • AC Charger
  • RJ45/11 Universal Coupler
  • Carrying Case

Click on a category to view a selection of compatible accessories with the Fluke Networks LIQ-100 Cable and Network Tester, 10 GB, 1000'.

Fluke Networks REMOTEID-1/Wiremapper for LinkIQ REMOTEID-1
Use the remote IDs for ethernet outlet identification and analyze each wire's length, pairing, and cable performance up to 10Gb/s for in-depth and reliable cable testing.




Fluke Networks REMOTEID-KIT Remote ID Kit for the LinkIQ and Microscanner PoE REMOTEID-KIT
Especially useful for identifying ethernet outlets, unique ports, or office outlets, these remote ID locators analyze wire length, pairing, and cable performance up to 10Gb/s for in-depth, reliable cable testing. Furthermore, this kit has six remote IDs to identify multiple wire map faults simultaneously.




Fluke Networks MS-IE-ADAPTER SET Industrial Ethernet Adapter Set MS-IE-ADAPTER SET
Use the Industrial Ethernet Remote Adapter to create a complete wire map of the cable pairs and identify miswired and split pairs on RJ45, M12X, M12D, and M8D terminated cables. Compatible with MicroScanner2, MicroScanner PoE, and LinkIQ, the Industrial Ethernet Adapter is versatile and reliable.




Ask a question about Fluke Networks LIQ-100 Cable and Network Tester, 10 GB, 1000'

Customer Reviews for the Fluke Networks LIQ-100

More Fluke Networks Products