Fluke Networks OFP2-100-MI OptiFiber Pro Multimode OTDR with Inspection

Model: OFP2-100-MI | UPC: 754082144335

Fluke Networks OFP2-100-MI OptiFiber Pro Multimode OTDR with Inspection

Model: OFP2-100-MI | UPC: 754082144335

The OFP-100-MI/INTL Pro Multimode OTDR kit is focused on reducing costs while enhancing productivity and improving network reliability. This is the non-wireless version and is available for countries where the WiFi adapter is not certified or for customers who do not wish to receive the WiFi adapter.

The OFP-100-MI/INTL Pro Multimode OTDR kit is focused on reducing costs while enhancing productivity and improving network reliability. This is the non-wireless version and is available for countries where the WiFi adapter is not certified or for customers who do not wish to receive the WiFi adapter.

Your Price $15315.00 USD
Availability 4 to 5 Weeks
Quantity

Fluke Networks OFP2-100-MI Offers

The OptiFiber® Pro OTDR elevates fiber optic testing with the industry's only smartphone interface that turns a technician into a fiber expert. The DataCenter OTDR configuration eliminates uncertainty and errors that occur when testing data center fiber. Its ultra-short dead zones enable testing of fiber patchcords in virtualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.

Features

  • First OTDR with a smartphone user-interface
  • Industry's shortest event and attenuation dead zones
  • Accelerate fiber certification with the fastest set-up and trace times
  • SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Instantaneous bi-directional averaging results included at no charge
  • Improve resource utilization with custom configurations for projects and users
  • Simplify use with "DataCenter OTDR™" mode and EventMap™ view

Applications

  • Data center monitoring and maintenance

Fluke Networks OFP2-100-MI Specifications

Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Event Dead Zone 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
Attenuation Dead Zone 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
Dynamic Range 850 nm: 28 dB typical
1300 nm: 30 dB typical
Max Distance Range Setting 40 km
Distance Measurement Range 850 nm: 9 km
1300 nm: 35 km
Reflectance Range 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
Sample Resolution 3 cm to 400 cm
Pulse Widths (Nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
Test Time (Per Wavelength) Auto Setting: 5 sec (Typical)
Quick Test Setting: 2 sec (Typical)
Best Resolution Setting: 2 to 180 sec
FaultMap Setting: 2 sec (Typical), 180 sec (Max)
DataCenter OTDR Setting: 1 sec (Typical at 850 nm), 7 sec (Max)
Manual Setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe
Magnification ~200X with OptiFiber Pro Display
Light Source Blue LED
Power Source Versiv Mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum Detectable Particle Size 0.5 µm
Dimensions Approximately 6.75" x 1.5" (1175 mm x 35 mm) Without Adapter Tip
Weight 200 g
Temperature Range Operating: 32 to 122°F (0 to +50°C)
Storage: -4 to +158°F (-20 to +70°C)
Certifications CE (when used with the mainframe)
VFL
On/Off Control Mechanical switch and a button on the touch screen
Output Power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating Wavelength 650 nm Nominal
Spectral Width (RMS) ±3 nm
Output Modes Continuous Wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm Universal
Laser Safety (Classification) Class II CDRH Complies to EN 60825-2
Environmental specifications
Operating temperature* -10 to 45°C
Storage Temperature -10 to +60°C
Operating Altitude 4,000 m (13,123 ft)
3,200 m (10,500 ft) with AC Adapter
Storage Altitude 12,000 m
EMC EN 61326-1
General Specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 x 5.25 x 11.0" ( 6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery Life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity
Click here for complete specifications on the Fluke Networks OFP2-100-MI

What's included with the Fluke Networks OFP2-100-MI

  • Versiv Mainframe
  • OptiFiber Pro Multimode OTDR Module
  • Shoulder Strap
  • USB Interface Cable
  • Versiv Open Source Software CD
  • AC Charger
  • 2 x Quick Clean Cleaners (1.25/2.50 mm)
  • 2 x SC/LC Multimode Launch Cables — 50 µm
  • OTDR Source Port Interchangeable LC adapters
  • USB Fiber Inspection Video Probe with 4 Tips
  • SC/SC Simplex Adaptor
  • 2 x Launch Fiber Hanging Straps and Magnets
  • Getting Started Guides

Ask a question about Fluke Networks OFP2-100-MI OptiFiber Pro Multimode OTDR with Inspection

Customer Reviews for the Fluke Networks OFP2-100-MI

Fluke Networks OFP2-100-MI Offers

The OptiFiber® Pro OTDR elevates fiber optic testing with the industry's only smartphone interface that turns a technician into a fiber expert. The DataCenter OTDR configuration eliminates uncertainty and errors that occur when testing data center fiber. Its ultra-short dead zones enable testing of fiber patchcords in virtualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.

Features

  • First OTDR with a smartphone user-interface
  • Industry's shortest event and attenuation dead zones
  • Accelerate fiber certification with the fastest set-up and trace times
  • SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Instantaneous bi-directional averaging results included at no charge
  • Improve resource utilization with custom configurations for projects and users
  • Simplify use with "DataCenter OTDR™" mode and EventMap™ view

Applications

  • Data center monitoring and maintenance

Fluke Networks OFP2-100-MI Specifications

Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Event Dead Zone 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
Attenuation Dead Zone 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
Dynamic Range 850 nm: 28 dB typical
1300 nm: 30 dB typical
Max Distance Range Setting 40 km
Distance Measurement Range 850 nm: 9 km
1300 nm: 35 km
Reflectance Range 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
Sample Resolution 3 cm to 400 cm
Pulse Widths (Nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
Test Time (Per Wavelength) Auto Setting: 5 sec (Typical)
Quick Test Setting: 2 sec (Typical)
Best Resolution Setting: 2 to 180 sec
FaultMap Setting: 2 sec (Typical), 180 sec (Max)
DataCenter OTDR Setting: 1 sec (Typical at 850 nm), 7 sec (Max)
Manual Setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe
Magnification ~200X with OptiFiber Pro Display
Light Source Blue LED
Power Source Versiv Mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum Detectable Particle Size 0.5 µm
Dimensions Approximately 6.75" x 1.5" (1175 mm x 35 mm) Without Adapter Tip
Weight 200 g
Temperature Range Operating: 32 to 122°F (0 to +50°C)
Storage: -4 to +158°F (-20 to +70°C)
Certifications CE (when used with the mainframe)
VFL
On/Off Control Mechanical switch and a button on the touch screen
Output Power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating Wavelength 650 nm Nominal
Spectral Width (RMS) ±3 nm
Output Modes Continuous Wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm Universal
Laser Safety (Classification) Class II CDRH Complies to EN 60825-2
Environmental specifications
Operating temperature* -10 to 45°C
Storage Temperature -10 to +60°C
Operating Altitude 4,000 m (13,123 ft)
3,200 m (10,500 ft) with AC Adapter
Storage Altitude 12,000 m
EMC EN 61326-1
General Specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 x 5.25 x 11.0" ( 6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery Life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity
Click here for complete specifications on the Fluke Networks OFP2-100-MI

What's included with the Fluke Networks OFP2-100-MI

  • Versiv Mainframe
  • OptiFiber Pro Multimode OTDR Module
  • Shoulder Strap
  • USB Interface Cable
  • Versiv Open Source Software CD
  • AC Charger
  • 2 x Quick Clean Cleaners (1.25/2.50 mm)
  • 2 x SC/LC Multimode Launch Cables — 50 µm
  • OTDR Source Port Interchangeable LC adapters
  • USB Fiber Inspection Video Probe with 4 Tips
  • SC/SC Simplex Adaptor
  • 2 x Launch Fiber Hanging Straps and Magnets
  • Getting Started Guides

Ask a question about Fluke Networks OFP2-100-MI OptiFiber Pro Multimode OTDR with Inspection

Customer Reviews for the Fluke Networks OFP2-100-MI

More Fluke Networks Products