The cable fault finder with BNC to banana to ABN is easy-to-use. It comes with a cable fault locator, a cable and wire manager and a tone generator with SmartTone technology. It finds the distance to opens or shorts on electrical wire, telephone wire, security wire and coax.
The cable fault finder with BNC to banana to ABN is easy-to-use. It comes with a cable fault locator, a cable and wire manager and a tone generator with SmartTone technology. It finds the distance to opens or shorts on electrical wire, telephone wire, security wire and coax.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Features
| Power | 4 AA alkaline batteries, provide 50 hours of operation |
| Reverse Battery Protection | No damage to the tester will occur if the batteries are installed backwards |
| Input Protection | 250 V rms ac, continuous or intermittent |
| Impedance Range | 35 to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings |
| Maximum Length | 2500 feet on certain cable types, 2000 feet on most cable types, and 500 feet on very lossy cables. The tester will display "Err" if the cable is too long to be correctly measured |
| Minimum Length | No minimum length Minimum non-zero reading is 2 feet |
| Operating | 0 to 80% |
| Storage | 0 to 100% |
| Weight | 1 lbs |
| Certifications and Compliance | CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |
| Power | 4 AA alkaline batteries, provide 50 hours of operation |
| Reverse Battery Protection | No damage to the tester will occur if the batteries are installed backwards |
| Input Protection | 250 V rms ac, continuous or intermittent |
| Impedance Range | 35 to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings |
| Maximum Length | 2500 feet on certain cable types, 2000 feet on most cable types, and 500 feet on very lossy cables. The tester will display "Err" if the cable is too long to be correctly measured |
| Minimum Length | No minimum length Minimum non-zero reading is 2 feet |
| Operating | 0 to 80% |
| Storage | 0 to 100% |
| Weight | 1 lbs |
| Certifications and Compliance | CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |