The Fluke CNX 3000 Industrial System is the ultimate collection of wireless test equipment for the industrial professional. This kit includes the CNX 3000 Multimeter v3000 AC Wireless Voltage Module Three (3) Fluke CNX i3000 iFlex AC Wireless Current Modules a Fluke CNX pc3000 Wireless PC Adapter and a wide selection of accessories.
The Fluke CNX 3000 Industrial System is the ultimate collection of wireless test equipment for the industrial professional. This kit includes the CNX 3000 Multimeter v3000 AC Wireless Voltage Module Three (3) Fluke CNX i3000 iFlex AC Wireless Current Modules a Fluke CNX pc3000 Wireless PC Adapter and a wide selection of accessories.
Discontinued!
This product has been discontinued and is no longer available. This is the direct replacement:
Model: 3000 FC Industrial Kit| Order No: 3000FC-IND
The Fluke Connect Industrial System is the ultimate collection of wireless test equipment. Includes the 3000 FC Multimeter, v3000 FC Wireless Voltage Module and Three (3) A3001 Wireless iFlex AC Current Modules.
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications
AC Voltage
Range
Resolution
Accuracy
45 Hz to 500 Hz
500 Hz to 1 kHz
600.0 mV
0.1 mV
1.0 % + 3
2.0 % + 3
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
Range
Resolution
Accuracy
mV
600.0 mV
0.1 mV
0.09 % + 2
V
6.000 V
0.001 V
0.09 % + 2
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
0.15 % + 2
)))
600 Ω
1 Ω
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω
600.0 Ω
0.1 Ω
0.5 % + 2
6.000 kΩ
0.001 kΩ
0.5 % + 1
60.00 kΩ
0.01 kΩ
60.00 kΩ
0.1 kΩ
600.0 kΩ
0.001 MΩ
50.00 MΩ
0.01 MΩ
1.5 % + 3
Diode test
2.000 V
0.001 V
1 % + 2
µF
1000 nF
1 nF
1.2 % + 2
10.00 μF
0.01 μF
100.0 μF
0.1 μF
9999 μF
1 μF
10 %
In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function
Range
Resolution
Accuracy
mA AC (45 Hz to 1 kHz)
60.00 mA
0.01 mA
1.5 % + 3
400.0 mA
0.1 mA
mA DC
60.00 mA
0.01 mA
0.5 % + 3
400.0 mA
0.1 mA
All AC current ranges are specified from 5 % of range to 100 % of range. Input burden voltage (typical): 400 mA input 2 mV/mA. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range
Resolution
Accuracy
99.99 Hz
0.01 Hz
0.1 % + 1
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function
Overload Protection
Input Impedance (nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)
Normal Mode Rejection
1100 V RMS
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
1100 V RMS
> 10 MΩ < 100 pF
> 60 dB, DC to 60 Hz
1100 V RMS
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
Open circuit test voltage
Full scale
Typical short circuit current
To 6 MΩ
50 MΩ
1100 V RMS
< 2.7 V DC
< 0.7 V DC
< 0.9 V DC
< 350 mA
1100 V RMS
< 2.7 V DC
2.000 V DC
< 1.1 mA
Function
Overload Protection
Overload
mA
Fused, 44/100 A, 1000 V FAST Fuse
600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
Function
Accuracy
DC functions
The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functions
The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration
General Specifications
Maximum voltage between any terminal and earth ground
1000 V DC or AC RMS
Ω fuse protection from A inputs
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity
0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C)
Altitude
Operating: 2,000 m Storage: 12,000 m
Temperature coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency
2.4 GHz ISM Band 20 meter range
Size (H x W x L)
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight
340 g (12 oz)
Safety standards
US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating
IP54
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage
Range
Resolution
Accuracy
45 Hz to 500 Hz
500 Hz to 1 kHz
6.000 V
0.001 V
1.0 % + 3
2.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
All AC voltage ranges are specified from 1 % of range to 100 % of range. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V. For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
General Specifications
LCD w/backlight
3½ digits, 6000 counts, updates 4/sec
Battery type
2 AA, NEDA 15 A, IEC LR6
Battery life
400 Hours
Memory
Record up to 65,000 readings
Unbound listen interval
5 seconds
RF communications
2.4 GHZ ISM Band
RF communication range
20 Meters
Operating temperature
-10 °C to +50 °C
Storage temperature
-40 °C to +60 °C
Operating humidity
90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
EMC
EN 61326-1:2006
Safety compliance
EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 61010-031:2002+A1:2008
Pollution degree
2
Temperature coefficient
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Safety rating
CAT IV 600 V, CAT III 1000 V
Certifications
CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating
IP42
Size (HxWxD)
16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight
.22 kg (8 oz)
Specifications
Range
2500 A AC
Resolution
0.1 A
Accuracy
3 % ± 5 digits
Crest factor (50 Hz/60 Hz)
3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display
3-1/2 digits, LCD w/backlight
Log rate/interval
1 sec minimum/adjustable by PC or front panel
Battery type
2 AA, NEDA 15 A, IEC LR6
Battery life
400 hours
Memory record
up to 65,000 readings
Unbound listen interval
5 seconds
RF communications
2.4 GHZ ISM Band
RF communication range
20 Meters
Operating temperature
-10 °C to +50 °C
Storage temperature
-40 °C to +60 °C
Operating humidity
90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC
EN 61326-1:2006
Safety compliance
EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 610101-2-031:2002 EN/IEC 61010-2-032:2002
Pollution degree
2
Temperature coefficient
Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.
Ask a question about Fluke CNX 3000 Industrial System
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications
AC Voltage
Range
Resolution
Accuracy
45 Hz to 500 Hz
500 Hz to 1 kHz
600.0 mV
0.1 mV
1.0 % + 3
2.0 % + 3
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
Range
Resolution
Accuracy
mV
600.0 mV
0.1 mV
0.09 % + 2
V
6.000 V
0.001 V
0.09 % + 2
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
0.15 % + 2
)))
600 Ω
1 Ω
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω
600.0 Ω
0.1 Ω
0.5 % + 2
6.000 kΩ
0.001 kΩ
0.5 % + 1
60.00 kΩ
0.01 kΩ
60.00 kΩ
0.1 kΩ
600.0 kΩ
0.001 MΩ
50.00 MΩ
0.01 MΩ
1.5 % + 3
Diode test
2.000 V
0.001 V
1 % + 2
µF
1000 nF
1 nF
1.2 % + 2
10.00 μF
0.01 μF
100.0 μF
0.1 μF
9999 μF
1 μF
10 %
In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function
Range
Resolution
Accuracy
mA AC (45 Hz to 1 kHz)
60.00 mA
0.01 mA
1.5 % + 3
400.0 mA
0.1 mA
mA DC
60.00 mA
0.01 mA
0.5 % + 3
400.0 mA
0.1 mA
All AC current ranges are specified from 5 % of range to 100 % of range. Input burden voltage (typical): 400 mA input 2 mV/mA. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range
Resolution
Accuracy
99.99 Hz
0.01 Hz
0.1 % + 1
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function
Overload Protection
Input Impedance (nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)
Normal Mode Rejection
1100 V RMS
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
1100 V RMS
> 10 MΩ < 100 pF
> 60 dB, DC to 60 Hz
1100 V RMS
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
Open circuit test voltage
Full scale
Typical short circuit current
To 6 MΩ
50 MΩ
1100 V RMS
< 2.7 V DC
< 0.7 V DC
< 0.9 V DC
< 350 mA
1100 V RMS
< 2.7 V DC
2.000 V DC
< 1.1 mA
Function
Overload Protection
Overload
mA
Fused, 44/100 A, 1000 V FAST Fuse
600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
Function
Accuracy
DC functions
The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functions
The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration
General Specifications
Maximum voltage between any terminal and earth ground
1000 V DC or AC RMS
Ω fuse protection from A inputs
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity
0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C)
Altitude
Operating: 2,000 m Storage: 12,000 m
Temperature coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency
2.4 GHz ISM Band 20 meter range
Size (H x W x L)
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight
340 g (12 oz)
Safety standards
US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating
IP54
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage
Range
Resolution
Accuracy
45 Hz to 500 Hz
500 Hz to 1 kHz
6.000 V
0.001 V
1.0 % + 3
2.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
All AC voltage ranges are specified from 1 % of range to 100 % of range. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V. For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
General Specifications
LCD w/backlight
3½ digits, 6000 counts, updates 4/sec
Battery type
2 AA, NEDA 15 A, IEC LR6
Battery life
400 Hours
Memory
Record up to 65,000 readings
Unbound listen interval
5 seconds
RF communications
2.4 GHZ ISM Band
RF communication range
20 Meters
Operating temperature
-10 °C to +50 °C
Storage temperature
-40 °C to +60 °C
Operating humidity
90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
EMC
EN 61326-1:2006
Safety compliance
EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 61010-031:2002+A1:2008
Pollution degree
2
Temperature coefficient
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Safety rating
CAT IV 600 V, CAT III 1000 V
Certifications
CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating
IP42
Size (HxWxD)
16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight
.22 kg (8 oz)
Specifications
Range
2500 A AC
Resolution
0.1 A
Accuracy
3 % ± 5 digits
Crest factor (50 Hz/60 Hz)
3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display
3-1/2 digits, LCD w/backlight
Log rate/interval
1 sec minimum/adjustable by PC or front panel
Battery type
2 AA, NEDA 15 A, IEC LR6
Battery life
400 hours
Memory record
up to 65,000 readings
Unbound listen interval
5 seconds
RF communications
2.4 GHZ ISM Band
RF communication range
20 Meters
Operating temperature
-10 °C to +50 °C
Storage temperature
-40 °C to +60 °C
Operating humidity
90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC
EN 61326-1:2006
Safety compliance
EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 610101-2-031:2002 EN/IEC 61010-2-032:2002
Pollution degree
2
Temperature coefficient
Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.
Our website gives you access to the best pricing we can offer. We encourage you to use our Build a Quote tool to build yourself a quote with the item(s) you’re interested in.
Your quote will then be emailed to you with all of the information you require. This also locks in your pricing for 30 days!
Check your Order Status
Check the status of your online order by entering your information below. Verify your order information is correct and the email address is what was used when you placed your order.
Ask our experts
To ask our Fluke experts a question please include your contact details. * Required Fields
Email Me When Available
Receive updates on when this product will be available for ordering.
*We don’t share your email. You can unsubscribe at any time.
Be the first to know!
Be the first to know when we have news, discounts, special offers and promotions.
*We don’t share your email. You can unsubscribe at any time.
Be the first to receive updates!
The Energy Monitoring System You've Been Waiting For!
Launching 2022
*We don’t share your email. You can unsubscribe at any time.
Exclusive Member Store
Don’t have a Member Account? Our Member Store gives you access to the following advantages:
Exclusive Member Pricing*
Exclusive Special Offers
Free Shipping on Online Orders over $199
Express Checkouts
Access to an additional 200 000+ Products via our Extended Search tool
Multiple Shipping Addresses
Additional Shipping Options
*Where applicable. Some of our pricing is already discounted.