IRT659K Industrial IR Laser Thermometer measures temperatures at a distance with a laser guide for improved aiming.
IRT659K Industrial IR Laser Thermometer measures temperatures at a distance with a laser guide for improved aiming.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Infrared Thermometers category for similar products.
Or let's do a search and help you find what you need:
The IRT659K laser thermometer is ideal for isolating overheated electrical components and hot spots, troubleshooting HVAC/R and automotive systems, and performance-testing motors and boilers.
Features
Applications
| Distance-to-spot (D) ratio | 0.500694444444444 |
| IRT measurement range | -58 to 1202°F (-50 to 650°C) |
| IRT measurement accuracy | ±3.6°F (±2°C) or ±2% of reading (whichever is greater) above 32°F (0°C); ±5.4°F (±3°C) or ±3% of reading (whichever is greater) below 32°F |
| "K" port measurement range | -146 to 2498°F (-99 to 1370°C) |
| "K" port measurement accuracy | ±(1% of reading + 1°C) above 32°F (0°C); ±(2% of reading + 2°C) below 32°F |
| Measurement range of included Type "K" stem thermocouple probe | -50 to 500°F (-45 to 260°C) |
| Measurement resolution | 0.1° below 1000°; 1° at and above 1000° |
| Emissivity | Adjustable from 0.1 to 1.0 in 0.01 increments, with factory default of 0.95 |
| Display size/type | 1.5"(38 mm) diagonal/LCD |
| Response time | 500 ms |
| Auto power off | After 30 seconds of inactivity |
| Operating temperature | 32 to 104°F (0 to 40°C) at 10 to 75% RH |
| Power source | 9V battery (included) |
| Weight | 6.93 oz. (168g) (without battery) |
| Distance-to-spot (D) ratio | 0.500694444444444 |
| IRT measurement range | -58 to 1202°F (-50 to 650°C) |
| IRT measurement accuracy | ±3.6°F (±2°C) or ±2% of reading (whichever is greater) above 32°F (0°C); ±5.4°F (±3°C) or ±3% of reading (whichever is greater) below 32°F |
| "K" port measurement range | -146 to 2498°F (-99 to 1370°C) |
| "K" port measurement accuracy | ±(1% of reading + 1°C) above 32°F (0°C); ±(2% of reading + 2°C) below 32°F |
| Measurement range of included Type "K" stem thermocouple probe | -50 to 500°F (-45 to 260°C) |
| Measurement resolution | 0.1° below 1000°; 1° at and above 1000° |
| Emissivity | Adjustable from 0.1 to 1.0 in 0.01 increments, with factory default of 0.95 |
| Display size/type | 1.5"(38 mm) diagonal/LCD |
| Response time | 500 ms |
| Auto power off | After 30 seconds of inactivity |
| Operating temperature | 32 to 104°F (0 to 40°C) at 10 to 75% RH |
| Power source | 9V battery (included) |
| Weight | 6.93 oz. (168g) (without battery) |