For use with logic amp, the floating voltage input probe is used as an accessory.
For use with logic amp, the floating voltage input probe is used as an accessory.
| Application | Checking relay coil voltage or the operational timing of voltage ON/OFF from the control panel unit |
| No. of Inputs | 4 channels (floating for each channel) |
| Input Range | High, Low |
| Input Resistance | High: approx. 100 kΩ Low: approx. 50 kΩ |
| Detectable Voltages | High: 100 to 250 VAC, 80 to 250 VDC Low: 50 to 150 VAC, 20 to 150 VDC |
| Non-Detectable Voltages | High: 0 to 20 VAC, 0 to 29 VDC Low: 0 to 10 VAC, 0 to 15 VDC |
| Response Times | High: within 1 ms, Low: within 3 ms |
| Maximum Floating Voltage | 250 VDC, ACp-p |