Hanna HI 98197 Ultra Pure Water EC/Resistivity Waterproof Portable Meter

Model: HI98197 | Order No: HI 98197

Hanna HI 98197 Ultra Pure Water EC/Resistivity Waterproof Portable Meter

Model: HI98197 | Order No: HI 98197

The waterproof portable meter is an EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. It is supplied complete with all accessories necessary to perform high purity water measurements packaged into a durable carrying case.

The waterproof portable meter is an EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. It is supplied complete with all accessories necessary to perform high purity water measurements packaged into a durable carrying case.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Laboratory Supplies/Equipment category for similar products.

Or let's do a search and help you find what you need:


Hanna HI98197 Offers

Features

  • Expanded Ranges
  • USP <645>
  • 5-Point Calibration
  • Temperature Compensation
  • TDS Conversion Factor
  • User Profiles
  • Logging
  • Good Laboratory Practice
  • Contextual Help
  • Graphic LCD
  • Thermoformed Carrying Case

Applications

  • Power Generation
  • Semiconductor Manufacturing

Hanna HI98197 Specifications

EC Range 0.000 to 9.999 μS/cm
10.00 to 99.99 μS/cm
100.0 to 999.9 μS/cm
1.000 to 9.999 mS/cm
10.00 to 99.99 mS/cm
100.0 to 1000.0 mS/cm
(actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution 0.001 μS/cm
0.01 μS/cm
0.1 μS/cm
0.001 mS/cm
0.01 mS/cm
0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibration Automatic up to five points with seven memorized standards:
0.00 μS/cm
84.0 μS/cm
1.413 mS/cm
5.00 mS/cm
12.88 mS/cm
80.0 mS/cm
111.8 mS/cm)
TDS Range 0.00 to 99.99 ppm
100.0 to 999.9 ppm
1.000 to 9.999 ppt (g/L)
10.00 to 99.99 ppt (g/L)
100.0 to 400.0 ppt (g/L)
TDS Resolution 0.01 ppm
0.1 ppm
0.001 ppt (g/L)
0.01 ppt (g/L)
0.1 ppt (g/L)
TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 Digit, Whichever is Greater)
TDS Calibration Based on Conductivity Calibration
Resistivity Range 1.0 to 99.9 Ω•cm
100 to 999 Ω•cm
1.00 to 9.99 KΩ•cm
10.0 to 99.9 KΩ•cm
100 to 999 KΩ•cm
1.00 to 9.99 MΩ•cm
10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm
1 Ω•cm
0.01 KΩ•cm
0.1 KΩ•cm
1 KΩ•cm
0.01 MΩ•cm
0.1 MΩ•cm
Resistivity Accuracy ±1% of Reading (±10 Ω or 1 Digit, Whichever is Greater)
Resistivity Calibration Based on Conductivity Calibration
Salinity Range % NaCl: 0.0 to 400.0%
Practical Salinity: 0.00 to 42.00 (PSU)
Natural Seawater Scale - UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution 0.1%
0.01
Salinity Accuracy ±1% of Reading
Salinity Calibration Max. one point only in % range (with HI7037 standard)
Use conductivity calibration for all other ranges
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.2°C; ±0.4°F (Excluding Probe Error)
Temperature Calibration One or Two Points
Temperature Compensation noTC
Linear: -20 to 120 °C (-4 to 248°F)
Non Linear - ISO/DIN 7888: 0 to 36 °C (32 to 96.8°F)
Measurement Modes Autorange, Autoend, Lock and Fixed Range
Reference Temperature 15°C, 20°C and 25°C
Temperature Coefficient 0.00 to 10.00 %/°C
TDS Factor 0.40 to 1.00
Electrode/Probe HI763123 Platinum, Four Ring Conductivity/TDS Probe with Internal Temperature Sensor and 1 m Cable (Included)
Log-on-demand 400 Samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles Up to 10
PC Connectivity Opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type 4 x 1.5V AA Batteries
Life Approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off User Selectable: 5, 10, 30, 60 min or can be disabled
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4")
Weight 400 g (14.2 oz.)
Warranty 2 Years (Probe 6 Months)
Click here for complete specifications on the Hanna HI98197

What's included with the Hanna HI98197

  • Ultra Pure Water EC/Resistivity Waterproof Portable Meter
  • Conductivity Probe
  • Stainless Steel Flow Cell
  • 84 μS/cm Calibration Solution (230 mL)
  • 1413 μS/cm Calibration Solution (230 mL)
  • 2 x 100 mL Plastic Beaker
  • PC Software
  • Micro USB Cable
  • 4 x 1.5V AA Batteries
  • Instructions
  • Rugged Carrying Case

Ask a question about Hanna HI 98197 Ultra Pure Water EC/Resistivity Waterproof Portable Meter

Customer Reviews for the Hanna HI98197

Hanna HI98197 Offers

Features

  • Expanded Ranges
  • USP <645>
  • 5-Point Calibration
  • Temperature Compensation
  • TDS Conversion Factor
  • User Profiles
  • Logging
  • Good Laboratory Practice
  • Contextual Help
  • Graphic LCD
  • Thermoformed Carrying Case

Applications

  • Power Generation
  • Semiconductor Manufacturing

Hanna HI98197 Specifications

EC Range 0.000 to 9.999 μS/cm
10.00 to 99.99 μS/cm
100.0 to 999.9 μS/cm
1.000 to 9.999 mS/cm
10.00 to 99.99 mS/cm
100.0 to 1000.0 mS/cm
(actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution 0.001 μS/cm
0.01 μS/cm
0.1 μS/cm
0.001 mS/cm
0.01 mS/cm
0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibration Automatic up to five points with seven memorized standards:
0.00 μS/cm
84.0 μS/cm
1.413 mS/cm
5.00 mS/cm
12.88 mS/cm
80.0 mS/cm
111.8 mS/cm)
TDS Range 0.00 to 99.99 ppm
100.0 to 999.9 ppm
1.000 to 9.999 ppt (g/L)
10.00 to 99.99 ppt (g/L)
100.0 to 400.0 ppt (g/L)
TDS Resolution 0.01 ppm
0.1 ppm
0.001 ppt (g/L)
0.01 ppt (g/L)
0.1 ppt (g/L)
TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 Digit, Whichever is Greater)
TDS Calibration Based on Conductivity Calibration
Resistivity Range 1.0 to 99.9 Ω•cm
100 to 999 Ω•cm
1.00 to 9.99 KΩ•cm
10.0 to 99.9 KΩ•cm
100 to 999 KΩ•cm
1.00 to 9.99 MΩ•cm
10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm
1 Ω•cm
0.01 KΩ•cm
0.1 KΩ•cm
1 KΩ•cm
0.01 MΩ•cm
0.1 MΩ•cm
Resistivity Accuracy ±1% of Reading (±10 Ω or 1 Digit, Whichever is Greater)
Resistivity Calibration Based on Conductivity Calibration
Salinity Range % NaCl: 0.0 to 400.0%
Practical Salinity: 0.00 to 42.00 (PSU)
Natural Seawater Scale - UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution 0.1%
0.01
Salinity Accuracy ±1% of Reading
Salinity Calibration Max. one point only in % range (with HI7037 standard)
Use conductivity calibration for all other ranges
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.2°C; ±0.4°F (Excluding Probe Error)
Temperature Calibration One or Two Points
Temperature Compensation noTC
Linear: -20 to 120 °C (-4 to 248°F)
Non Linear - ISO/DIN 7888: 0 to 36 °C (32 to 96.8°F)
Measurement Modes Autorange, Autoend, Lock and Fixed Range
Reference Temperature 15°C, 20°C and 25°C
Temperature Coefficient 0.00 to 10.00 %/°C
TDS Factor 0.40 to 1.00
Electrode/Probe HI763123 Platinum, Four Ring Conductivity/TDS Probe with Internal Temperature Sensor and 1 m Cable (Included)
Log-on-demand 400 Samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles Up to 10
PC Connectivity Opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type 4 x 1.5V AA Batteries
Life Approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off User Selectable: 5, 10, 30, 60 min or can be disabled
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4")
Weight 400 g (14.2 oz.)
Warranty 2 Years (Probe 6 Months)
Click here for complete specifications on the Hanna HI98197

What's included with the Hanna HI98197

  • Ultra Pure Water EC/Resistivity Waterproof Portable Meter
  • Conductivity Probe
  • Stainless Steel Flow Cell
  • 84 μS/cm Calibration Solution (230 mL)
  • 1413 μS/cm Calibration Solution (230 mL)
  • 2 x 100 mL Plastic Beaker
  • PC Software
  • Micro USB Cable
  • 4 x 1.5V AA Batteries
  • Instructions
  • Rugged Carrying Case

Ask a question about Hanna HI 98197 Ultra Pure Water EC/Resistivity Waterproof Portable Meter

Customer Reviews for the Hanna HI98197

More Hanna Products