Hanna HI96831 Digital Refractometer for Ethylene Glycol Analysis

Model: HI96831 | Order No: HI 96831

Hanna HI96831 Digital Refractometer for Ethylene Glycol Analysis

Model: HI96831 | Order No: HI 96831

A portable refractometer designed for the measurement of percent volume and freezing point of ethylene glycol based solutions. With a simple operation and reliable results every time.

A portable refractometer designed for the measurement of percent volume and freezing point of ethylene glycol based solutions. With a simple operation and reliable results every time.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

ATAGO PAL-92S Refractometer, Ethylene Glycol, F-

ATAGO PAL-92S Refractometer, Ethylene Glycol, F

Model: 4492 | Order No: PAL-92S

Pocket sized, digital refractometers for coolants. Only 2 to 3 sample drops are required for a reading in 2 to 3 seconds.


Not what you're looking for? Let’s do a search and help you find what you need.


Hanna HI96831 Offers

Features

  • One-point calibration
  • Small sample size
  • Automatic Temperature Compensation (ATC)
  • Quick, accurate results
  • Dual-level LCD
  • Stainless steel sample well
  • Battery indicators
  • Automatic shut-off
  • IP65 water resistant protection

Applications

  • Place container (such as a glass vial or dropper bottle that has a cover) on an analytical balance
  • Tare the balance
  • To make an X BRIX solution, weigh out X grams of high purity Sucrose (CAS #: 57-50-1) directly into the container
  • Add distilled or deionized water to the container so the total weight of the solution is 100g
  • Note: Solutions above 60% Brix need to be vigorously stirred or shaken and heated in a water bath. Remove solution from bath when sucrose has dissolved. The total quantity can be scaled proportionally for smaller containers but accuracy may be sacrificed

Hanna HI96831 Specifications

Percent Volume Range (% V/V) 0 to 100%
Percent Volume Resolution (% V/V) 0.1 %
Percent Volume Accuracy (% V/V) @20°C/68°F ±0.2 %
Freezing Point Range 0 to -50 °C (32 to -58 °F)
Freezing Point Resolution 0.1 °C (0.1 °F)
Freezing Point Accuracy (@25°C/77°F) ±0.5 °C (±1.0 °F)
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 0 and 40°C (32 to 104°F)
Measurement Time approximately 1.5 seconds
Minimum Sample Volume 100 μL (to cover prism totally)
Light Source yellow LED
Sample Cell stainless steel ring and flint glass prism
Auto-off after three minutes of inactivity
Enclosure Rating IP65
Battery Life approximately 5000 readings
Dimensions / Weight 192 x 102 x 67 mm (7.6 x 4.01 x 2.6") / 420 g (14.8 oz.)
Click here for complete specifications on the Hanna HI96831

What's included with the Hanna HI96831

  • Hanna HI96831 Digital refractometer for Ethylene Glycol Analysis
  • 9V Battery

Ask a question about Hanna HI96831 Digital Refractometer for Ethylene Glycol Analysis

Customer Reviews for the Hanna HI96831

Hanna HI96831 Offers

Features

  • One-point calibration
  • Small sample size
  • Automatic Temperature Compensation (ATC)
  • Quick, accurate results
  • Dual-level LCD
  • Stainless steel sample well
  • Battery indicators
  • Automatic shut-off
  • IP65 water resistant protection

Applications

  • Place container (such as a glass vial or dropper bottle that has a cover) on an analytical balance
  • Tare the balance
  • To make an X BRIX solution, weigh out X grams of high purity Sucrose (CAS #: 57-50-1) directly into the container
  • Add distilled or deionized water to the container so the total weight of the solution is 100g
  • Note: Solutions above 60% Brix need to be vigorously stirred or shaken and heated in a water bath. Remove solution from bath when sucrose has dissolved. The total quantity can be scaled proportionally for smaller containers but accuracy may be sacrificed

Hanna HI96831 Specifications

Percent Volume Range (% V/V) 0 to 100%
Percent Volume Resolution (% V/V) 0.1 %
Percent Volume Accuracy (% V/V) @20°C/68°F ±0.2 %
Freezing Point Range 0 to -50 °C (32 to -58 °F)
Freezing Point Resolution 0.1 °C (0.1 °F)
Freezing Point Accuracy (@25°C/77°F) ±0.5 °C (±1.0 °F)
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 0 and 40°C (32 to 104°F)
Measurement Time approximately 1.5 seconds
Minimum Sample Volume 100 μL (to cover prism totally)
Light Source yellow LED
Sample Cell stainless steel ring and flint glass prism
Auto-off after three minutes of inactivity
Enclosure Rating IP65
Battery Life approximately 5000 readings
Dimensions / Weight 192 x 102 x 67 mm (7.6 x 4.01 x 2.6") / 420 g (14.8 oz.)
Click here for complete specifications on the Hanna HI96831

What's included with the Hanna HI96831

  • Hanna HI96831 Digital refractometer for Ethylene Glycol Analysis
  • 9V Battery

Ask a question about Hanna HI96831 Digital Refractometer for Ethylene Glycol Analysis

Customer Reviews for the Hanna HI96831

More Hanna Products