Hanna HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Model: HI98192 | Order No: HI 98192

Hanna HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Model: HI98192 | Order No: HI 98192

This heavy-duty conductivity meter is designed to provide laboratory results and accuracy under harsh industrial conditions. Offering three salinity modes: % NaCl, Practical salinity and Natural seawater scale. This meter is supplied with all accessories to perform the necessary measurememnts.

This heavy-duty conductivity meter is designed to provide laboratory results and accuracy under harsh industrial conditions. Offering three salinity modes: % NaCl, Practical salinity and Natural seawater scale. This meter is supplied with all accessories to perform the necessary measurememnts.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Electrodes category for similar products.

Or let's do a search and help you find what you need:


Hanna HI98192 Offers

Features

  • Compact, rugged, waterproof (IP67) design
  • Methods - USP <645> capable for checking the quality of water used in pharmaceutical manufacturing
  • Salinity readings
  • Auto-ranging and fixed range options
  • Calibration
  • GLP Features
  • Calibration timeout to alert the user at a defined interval when the calibration has expired
  • Auto Hold
  • Multiple language selection
  • Temperature compensation
  • Data logging
  • Connectivity - PC connectivity via opto-isolated USB with optional HI92000 software
  • 100-hour battery life
  • Menu driven for ease of use with virtual-key extended functionality
  • Contextual help at the press of a button
  • Backlit, Graphic LCD

Applications

  • Environmental
  • pharmaceutical
  • plating
  • water treatment
  • food manufacturing
  • water and wastewater

Hanna HI98192 Specifications

EC Range 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
Resistivity Accuracy ±1% of reading (±10 Ω or 1 digit, whichever is greater)
Salinity Range % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale - UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution 0.1%; 0.01
Salinity Accuracy ±1% of reading
Salinity Calibration max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.2°C; ±0.4°F (excluding probe error)
Temperature Calibration one or two points
Temperature Compensation noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Measurement Modes autorange, autoend, lock and fixed range
Reference Temperature 15°C, 20°C and 25°C
Temperature Coefficient 0.00 to 10.00 %/°C
TDS Factor 0.40 to 1.00
Electrode/Probe HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2') cable (included)
Log-on-demand 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles up to 10
PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off user selectable: 5, 10, 30, 60 min or can be disabled
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4")
Weight 400 g (14.2 oz.)
Notes *The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe
Click here for complete specifications on the Hanna HI98192

What's included with the Hanna HI98192

  • Hanna HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter
  • HI763133 Conductivity probe
  • HI7031M 1413 μS/cm Calibration solution (230 mL)
  • HI7035M 111.8 mS/cm Calibration solution (230 mL)
  • 2 x 100 mL Plastic beaker
  • HI92000 PC software
  • HI920015 Micro USB cable
  • Quality certificate
  • HI720192 Rugged carrying case
  • 4 x 1.5V AA batteries

Ask a question about Hanna HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Customer Reviews for the Hanna HI98192

Hanna HI98192 Offers

Features

  • Compact, rugged, waterproof (IP67) design
  • Methods - USP <645> capable for checking the quality of water used in pharmaceutical manufacturing
  • Salinity readings
  • Auto-ranging and fixed range options
  • Calibration
  • GLP Features
  • Calibration timeout to alert the user at a defined interval when the calibration has expired
  • Auto Hold
  • Multiple language selection
  • Temperature compensation
  • Data logging
  • Connectivity - PC connectivity via opto-isolated USB with optional HI92000 software
  • 100-hour battery life
  • Menu driven for ease of use with virtual-key extended functionality
  • Contextual help at the press of a button
  • Backlit, Graphic LCD

Applications

  • Environmental
  • pharmaceutical
  • plating
  • water treatment
  • food manufacturing
  • water and wastewater

Hanna HI98192 Specifications

EC Range 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
Resistivity Accuracy ±1% of reading (±10 Ω or 1 digit, whichever is greater)
Salinity Range % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale - UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution 0.1%; 0.01
Salinity Accuracy ±1% of reading
Salinity Calibration max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.2°C; ±0.4°F (excluding probe error)
Temperature Calibration one or two points
Temperature Compensation noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Measurement Modes autorange, autoend, lock and fixed range
Reference Temperature 15°C, 20°C and 25°C
Temperature Coefficient 0.00 to 10.00 %/°C
TDS Factor 0.40 to 1.00
Electrode/Probe HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2') cable (included)
Log-on-demand 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles up to 10
PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off user selectable: 5, 10, 30, 60 min or can be disabled
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4")
Weight 400 g (14.2 oz.)
Notes *The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe
Click here for complete specifications on the Hanna HI98192

What's included with the Hanna HI98192

  • Hanna HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter
  • HI763133 Conductivity probe
  • HI7031M 1413 μS/cm Calibration solution (230 mL)
  • HI7035M 111.8 mS/cm Calibration solution (230 mL)
  • 2 x 100 mL Plastic beaker
  • HI92000 PC software
  • HI920015 Micro USB cable
  • Quality certificate
  • HI720192 Rugged carrying case
  • 4 x 1.5V AA batteries

Ask a question about Hanna HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Customer Reviews for the Hanna HI98192

More Hanna Products