High voltage scanner that allows high voltage inputs to be output from any channel. A single unit is equipped with 8 channels (using single mode), and up to four units can be connected to give a total of 32 channels. In addition, it can be used in combination with the 3153, displaying its capabilities as an unattended automatic testing device for multiple point insulation and AC/DC voltage endurance testing.
High voltage scanner that allows high voltage inputs to be output from any channel. A single unit is equipped with 8 channels (using single mode), and up to four units can be connected to give a total of 32 channels. In addition, it can be used in combination with the 3153, displaying its capabilities as an unattended automatic testing device for multiple point insulation and AC/DC voltage endurance testing.
Features isolated high voltage input and output, as well as insulated control signal lines and an insulated power cord. Further,when multiple units are connected, the 3930 can detect wrongly set (duplicated) IDs and stop all output.
It also has two operation modes, single mode and multi-mode. The single mode has a common channel with eight high channels, while the multi-mode has four high and four low channels, and the 3930 can scan any point on these channels.
In addition its control using the 3153's program function, the 3930 is a multi-purpose high voltage scanner that can be controlled using general logic and a sequencer. A maximum of four units can be connected at any one time. When using the 3930 in combination with the 3153, a separate power source is not necessary, since power is supplied from the control signal input connector.
Features
Operation temperature range | 0 ̊C to 40 ̊C, 80% rh or less (no condensation) |
Storage temperature range | -10 ̊C to 50 ̊C, 90% rh or less (no condensation) |
Operation environment | Indoors, altitude of 2000 m or less |
Withstand voltage | High voltage terminal - between the chassis: AC 10 kV, 10 mA, 1 min |
Power | VSCV24 V DC, ±10% |
Maximum rated power | 12 VA |
Measurements | Approx. 316 (W) ×100 (H) ×350 (D) mm |
Weight> | Approx. 4.2 kg |
Operation temperature range | 0 ̊C to 40 ̊C, 80% rh or less (no condensation) |
Storage temperature range | -10 ̊C to 50 ̊C, 90% rh or less (no condensation) |
Operation environment | Indoors, altitude of 2000 m or less |
Withstand voltage | High voltage terminal - between the chassis: AC 10 kV, 10 mA, 1 min |
Power | VSCV24 V DC, ±10% |
Maximum rated power | 12 VA |
Measurements | Approx. 316 (W) ×100 (H) ×350 (D) mm |
Weight> | Approx. 4.2 kg |