Monitor electrical current from 20 to 1,000A with this clamp-on AC probe. The probe can be used with digital multimeters and Memory HiCorders for versatile use.
Monitor electrical current from 20 to 1,000A with this clamp-on AC probe. The probe can be used with digital multimeters and Memory HiCorders for versatile use.
When this Hioki 9132-50 Clamp-On AC Probe is connected to your DMM or Memory HiCorder, you'll be able to measure the electrical current between 20 to 1,000 A AC. You can also choose from 6 selectable ranges.
Features
Rated Current | 20 to 1,000 A AC, 6 ranges |
Accuracy | ±3% of reading ±0.2% f.s. (45 to 66 Hz) |
Output Rate | 0.2 VAC f.s. |
Maximum Allowable Input | 1,000 Arms continuous (all ranges), 100% of 40 to 500 Hz, within 90% of derating for 500 Hz to 1 kHz |
Maximum Rated Voltage to Earth | 600 Vrms (50/60 Hz, Cat III) |
Output Terminal | BNC terminal |
Core Diameter | 2.17" (55 mm), 0.79" (20 mm) x 3.15" (80 mm) busbar |
Product Length | 1.38" (35 mm), 9.84' (3 m) cord |
Product Width | 3.94" (100 mm) |
Product Height | 8.82" (224 mm) |
Product Weight | 21.2 oz (600 g) |
Rated Current | 20 to 1,000 A AC, 6 ranges |
Accuracy | ±3% of reading ±0.2% f.s. (45 to 66 Hz) |
Output Rate | 0.2 VAC f.s. |
Maximum Allowable Input | 1,000 Arms continuous (all ranges), 100% of 40 to 500 Hz, within 90% of derating for 500 Hz to 1 kHz |
Maximum Rated Voltage to Earth | 600 Vrms (50/60 Hz, Cat III) |
Output Terminal | BNC terminal |
Core Diameter | 2.17" (55 mm), 0.79" (20 mm) x 3.15" (80 mm) busbar |
Product Length | 1.38" (35 mm), 9.84' (3 m) cord |
Product Width | 3.94" (100 mm) |
Product Height | 8.82" (224 mm) |
Product Weight | 21.2 oz (600 g) |