When you connect this probe to your Memory HiCorder, you'll be able to measure 3 types of electrical signals. The probe offers DC, AC and RMS modes for simplified operation.
When you connect this probe to your Memory HiCorder, you'll be able to measure 3 types of electrical signals. The probe offers DC, AC and RMS modes for simplified operation.
Capable of performing 3 types of measurements, this Hioki 9322 Memory HiCorder Differential Probe is ideal for use with your compatible Memory HiCorder model. The probe offers measurement of high-voltage waveforms, power supply surge noise and RMS rectified output.
Features
DC Mode | DC to 10 MHz ±3 dB, waveform monitor output |
AC Mode | 1 kHz to 10 MHz ±3 dB, detection of power line surge noise |
RMS Mode | 40 Hz to 100 kHz, rectified RMS output of DC and AC voltages |
Response Speed | 200 ms or less (400 VAC) |
Output Terminal | BNC |
DC Amplitude Accuracy | ±1% full scale (1,000 VDC or less), ±3% full scale (2,000 VDC or less) |
RMS Amplitude Accuracy | ±1% full scale (DC, 40 Hz to 1 kHz), ±4% full scale (1 to 100 kHz) |
Input Resistance, Capacity | 9 MΩ (H-L, approximately 10 pF, C at 100 kHz), 4.5 MΩ (H-Case, L-case, approximately 20 pF, C at 100 kHz) |
Maximum Allowable Input | 600 VAC/VDC (Cat III), 2,000 VDC, 1,000 VAC (Cat II) |
Maximum Rated Voltage to Earth | 600 VAC/DC (Cat III)/1,500 VAC/DC (Cat II) when using grabber clip, 600 VAC/DC (Cat III)/1,000 VAC/DC (Cat II) when using alligator clip |
Power Supply | 9418-15 AC adapter or power supply through power cord 9324 connected to logic terminal on Memory HiCorder |
CE Compliant | Yes |
Product Length | 0.98" (25 mm) main unit, 1.51' (46 cm) input cord, 4.27' (1.3 m) output cord |
Product Width | 2.76" (70 mm) main unit |
Product Height | 5.91" (150 mm) main unit |
Product Weight | 12.3 oz (350 g) |
DC Mode | DC to 10 MHz ±3 dB, waveform monitor output |
AC Mode | 1 kHz to 10 MHz ±3 dB, detection of power line surge noise |
RMS Mode | 40 Hz to 100 kHz, rectified RMS output of DC and AC voltages |
Response Speed | 200 ms or less (400 VAC) |
Output Terminal | BNC |
DC Amplitude Accuracy | ±1% full scale (1,000 VDC or less), ±3% full scale (2,000 VDC or less) |
RMS Amplitude Accuracy | ±1% full scale (DC, 40 Hz to 1 kHz), ±4% full scale (1 to 100 kHz) |
Input Resistance, Capacity | 9 MΩ (H-L, approximately 10 pF, C at 100 kHz), 4.5 MΩ (H-Case, L-case, approximately 20 pF, C at 100 kHz) |
Maximum Allowable Input | 600 VAC/VDC (Cat III), 2,000 VDC, 1,000 VAC (Cat II) |
Maximum Rated Voltage to Earth | 600 VAC/DC (Cat III)/1,500 VAC/DC (Cat II) when using grabber clip, 600 VAC/DC (Cat III)/1,000 VAC/DC (Cat II) when using alligator clip |
Power Supply | 9418-15 AC adapter or power supply through power cord 9324 connected to logic terminal on Memory HiCorder |
CE Compliant | Yes |
Product Length | 0.98" (25 mm) main unit, 1.51' (46 cm) input cord, 4.27' (1.3 m) output cord |
Product Width | 2.76" (70 mm) main unit |
Product Height | 5.91" (150 mm) main unit |
Product Weight | 12.3 oz (350 g) |