Measure leak current with this clamp-on sensor. The sensor is capable of measuring 10A AC with your compatible Hioki device.
Measure leak current with this clamp-on sensor. The sensor is capable of measuring 10A AC with your compatible Hioki device.
When you connect this Hioki 9675 Clamp-On Voltage Output Leak Current Sensor to your Hioki 3169, 3197, LR5051 or PW3198 device (sold separately), you'll be able to measure leak current up to 10A AC. The clamp-on design provides safe and easy attachment to wires.
Features
Compatibility | Hioki 3169, 3197, LR5051 and PW3198 models |
Rated Primary Current | 10A AC (for leak current measurement, 50/60Hz) |
Maximum Allowable Input | 10A continuous (45 to 66Hz) |
Rated Output Current | 100mV/A AC |
Amplitude Accuracy | ±1% of reading, ±0.005% of full scale |
Phase Accuracy | ±5° (at 50 or 60Hz) |
Frequency | 40Hz to 5kHz ±5% |
Core Diameter | φ1.18in (30mm) |
CE Compliant | Yes |
Product Length | 0.93in (23.6mm) unit, 9.84ft (3m) cord |
Product Width | 2.36in (60mm) |
Product Height | 4.43in (112.5mm) |
Product Weight | 5.6oz (160g) |
Compatibility | Hioki 3169, 3197, LR5051 and PW3198 models |
Rated Primary Current | 10A AC (for leak current measurement, 50/60Hz) |
Maximum Allowable Input | 10A continuous (45 to 66Hz) |
Rated Output Current | 100mV/A AC |
Amplitude Accuracy | ±1% of reading, ±0.005% of full scale |
Phase Accuracy | ±5° (at 50 or 60Hz) |
Frequency | 40Hz to 5kHz ±5% |
Core Diameter | φ1.18in (30mm) |
CE Compliant | Yes |
Product Length | 0.93in (23.6mm) unit, 9.84ft (3m) cord |
Product Width | 2.36in (60mm) |
Product Height | 4.43in (112.5mm) |
Product Weight | 5.6oz (160g) |