The high-sensitivity probe offers a bandwidth of DC to 120 MHz and a 200 μA to 30 A input, allowing you to capture signals from across an expansive current range, such as from a stead state to transient currents, or when developing switching power supplies, inverters, or motor controllers.
The high-sensitivity probe offers a bandwidth of DC to 120 MHz and a 200 μA to 30 A input, allowing you to capture signals from across an expansive current range, such as from a stead state to transient currents, or when developing switching power supplies, inverters, or motor controllers.
Features
Frequency Bandwidth | DC to 120 MHz (-3 dB) |
Rise Time | 2.9 ns or shorter |
Delay time (Typical) | 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns (Delay time relative to rising waveform of input signal 1 ns) |
Noise Level | 75 µA rms max (at 0.5 A range, using 20 MHz band measuring instrument) |
Max. Rated Current | 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms (DC, and sine wave, requires derating at frequency) |
Max. Allowable Peak Current | 30 A range: ±50 A peak (within the input limit time 2 s) 5 A range: ±7.5 A peak, 0.5 A range: ±0.75 A peak (<10 MHz), ±0.3 A peak (≥10 MHz) |
Output Rate | 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A, (The output of this probe is internally terminated, so connect to voltage input equipment with high input impedance such as 1 MΩ) |
Measurable Conductors | φ 0.20" (5 mm), Insulated conductor |
Cable Length | Sensor cable (between relay box and sensor): 4.92' (1.5 mm) Power cable: 3.28' (1 m) (Power plug: FFA.0S.304.CLAC37Y / LEMO inc.) |
Dimensions | Sensor: 6.10 x 0.71 x 1.02" (155 x 18 x 26 mm), Relay box section: 1.77 x 4.72 x 0.98" (45 x 120 x 25 mm) Terminator section: 1.14 x 3.27 x 1.57" (29 x 83 x 40 mm) |
Weight | 370 g (13.1 oz) |
Power Supply | Supplied from Power Supply 3269, Probe Power Unit Z5021 |
Frequency Bandwidth | DC to 120 MHz (-3 dB) |
Rise Time | 2.9 ns or shorter |
Delay time (Typical) | 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns (Delay time relative to rising waveform of input signal 1 ns) |
Noise Level | 75 µA rms max (at 0.5 A range, using 20 MHz band measuring instrument) |
Max. Rated Current | 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms (DC, and sine wave, requires derating at frequency) |
Max. Allowable Peak Current | 30 A range: ±50 A peak (within the input limit time 2 s) 5 A range: ±7.5 A peak, 0.5 A range: ±0.75 A peak (<10 MHz), ±0.3 A peak (≥10 MHz) |
Output Rate | 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A, (The output of this probe is internally terminated, so connect to voltage input equipment with high input impedance such as 1 MΩ) |
Measurable Conductors | φ 0.20" (5 mm), Insulated conductor |
Cable Length | Sensor cable (between relay box and sensor): 4.92' (1.5 mm) Power cable: 3.28' (1 m) (Power plug: FFA.0S.304.CLAC37Y / LEMO inc.) |
Dimensions | Sensor: 6.10 x 0.71 x 1.02" (155 x 18 x 26 mm), Relay box section: 1.77 x 4.72 x 0.98" (45 x 120 x 25 mm) Terminator section: 1.14 x 3.27 x 1.57" (29 x 83 x 40 mm) |
Weight | 370 g (13.1 oz) |
Power Supply | Supplied from Power Supply 3269, Probe Power Unit Z5021 |