A field-capable, fast-working earth tester featuring extensive measurement functionality for reliable ground resistance testing.
A field-capable, fast-working earth tester featuring extensive measurement functionality for reliable ground resistance testing.
Features
Extensive measurement functionality: choose the right measurement method for any application
4-pole method (Wenner's 4-pole method):
3-pole method:
MEC (Measuring Earth with a Clamp) function:
3-pole method using 4-terminal measurement:
2-clamp method:
Low-resistance measurement:
Measure ground resistance without disconnecting ground electrodes: MEC(*) function
This function augments the 3-pole method with current measurement using a clamp sensor. By measuring only current flowing to the grounding electrode you wish to measure, you can avoid the effects of other grounds. This capability can substantially reduce man-hours spent on measurement work.
*MEC stands for "measuring earth with a clamp."
Measure soil resistivity when surveying a grounding design by 4-pole method
Soil resistivity is measured as part of the grounding design process in advance of building design. Soil resistivity varies with each site’s geological properties. In this process, optimal ground locations as well as grounding electrode shapes, dimensions, and other characteristics are designed based on the assessed soil resistivity.
Built tough to withstand use at harsh sites
Dirt, sand, and rain resistance, IP67 dust and water protection Since the Earth Tester FT6041 is designed to keep dust and dirt out of its enclosure, you can use it in the field without worrying about mud or dust. If it gets dirty, simply rinse it off with water.
Operating temperature range -25°C to 65°C
Drop-proof design 1 m with protector attached
Excellent noise resistance, Allowable ground potential: 30.0 V RMS
Designed to shorten work times and reduce operator workload
Fast measurement! Cord rewinding that doesn’t tangle or twist
Insert just once thanks to 100 kΩ max. allowable resistance
Make measurements, even on concrete. Newly designed Earth Nets Module L9846
Unique clamp sensor for tight spaces
Earth electrodes are located at the tight spaces. On top of that, some bus bars are also thick. The CT9848 clamping sensor can be used to clamp those points.
The thin, wide bore jaws allow for smooth clamping of the ground electrodes.
Wireless support - It transfers measurements to your smartphone or tablet
Compatible with Wireless Adapter Z3210 (optional). It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.
GENNECT Cross, a free app designed specifically for use with Hioki measuring instruments, lets you check and manage measurement results and create reports.
The software provides a range of functionality that helps manage data in the field, including photographing measurement sites, placing measurement results on photographs, and saving hand written memos.
| Measurement Parameters | Ground resistance measurement: 4-pole method, 3-pole method, 2-pole method, MEC function, clamp-on measurement (two clamps) Soil resistivity measurement: 4-pole method Low-resistance measurement: 4-terminal method, 2-terminal method Ground potential measurement |
| Ground Potential | 0 to 30.0 V RMS, accuracy: ±2.3% rdg. ±8 dgt. (50/60 Hz), ±1.3% rdg. ±4 dgt. (DC) |
| Functions | Live wire warning, auto power save, soil resistivity display (4-pole method only), zero-adjustment, auto-hold, continuous measurement mode, wireless communication (only when Z3210 is connected), buzzer sound, comparator, switching the display, ground potential overload display (when measuring ground resistance) |
| Standards | EN61010 (safety), EN61326 (EMC), EN61557-1/EN61557-10/EN61557-14 (low-resistance measurement, earth testers), EN61557-5 (earth testers) |
| Dustproof and Waterproof | IP65, IP67 (EN60529) |
Click on a category to view a selection of compatible accessories with the Hioki FT6041 Earth Tester, 3 Ω to 300 kΩ.
| Measurement Parameters | Ground resistance measurement: 4-pole method, 3-pole method, 2-pole method, MEC function, clamp-on measurement (two clamps) Soil resistivity measurement: 4-pole method Low-resistance measurement: 4-terminal method, 2-terminal method Ground potential measurement |
| Ground Potential | 0 to 30.0 V RMS, accuracy: ±2.3% rdg. ±8 dgt. (50/60 Hz), ±1.3% rdg. ±4 dgt. (DC) |
| Functions | Live wire warning, auto power save, soil resistivity display (4-pole method only), zero-adjustment, auto-hold, continuous measurement mode, wireless communication (only when Z3210 is connected), buzzer sound, comparator, switching the display, ground potential overload display (when measuring ground resistance) |
| Standards | EN61010 (safety), EN61326 (EMC), EN61557-1/EN61557-10/EN61557-14 (low-resistance measurement, earth testers), EN61557-5 (earth testers) |
| Dustproof and Waterproof | IP65, IP67 (EN60529) |
Click on a category to view a selection of compatible accessories with the Hioki FT6041 Earth Tester, 3 Ω to 300 kΩ.