The voltage of the solar installations (also known as photovoltaic or PV installations) increases to reduce cost and improve the efficiency of solar equipment. As a result, it is important to select measuring instruments that support higher voltage measurement to protect the safety of inspection workers.
Features
Applications
| Maximum Input Voltage | DC 2000 V |
| Maximum Rated Line-To-Ground Voltage | 1000 V (measurement category IV), anticipated transient over voltage 12,000 V 2000 V (measurement category III), anticipated transient over voltage 15,000 V |
| Input Resistance | 20 MΩ ±5% (between INPUT H and INPUT L, when OUTPUT terminal is open) |
| Overload Protection | 2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L) 600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) |
| Output Terminal | 0.16" (4 mm) banana terminal |
| Operating Temperature | -13 to 149°F (-25 to 65°C) |
| Humidity Range | −13 to 104°F (-25 to 40°C): 80% RH or less (non-condensing) 104 to 149°F (40 to 65°C): Linearly reduces from 80% RH or less at 104°F (40°C) to 25% RH or less at 149°F (65°C) (non-condensing) |
| Storage Temperature and Humidity Range | -22 to 158°F (-30 to 70°C) 90% RH or less (non-condensing) |
| Maximum Input Voltage | DC 2000 V |
| Maximum Rated Line-To-Ground Voltage | 1000 V (measurement category IV), anticipated transient over voltage 12,000 V 2000 V (measurement category III), anticipated transient over voltage 15,000 V |
| Input Resistance | 20 MΩ ±5% (between INPUT H and INPUT L, when OUTPUT terminal is open) |
| Overload Protection | 2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L) 600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) |
| Output Terminal | 0.16" (4 mm) banana terminal |
| Operating Temperature | -13 to 149°F (-25 to 65°C) |
| Humidity Range | −13 to 104°F (-25 to 40°C): 80% RH or less (non-condensing) 104 to 149°F (40 to 65°C): Linearly reduces from 80% RH or less at 104°F (40°C) to 25% RH or less at 149°F (65°C) (non-condensing) |
| Storage Temperature and Humidity Range | -22 to 158°F (-30 to 70°C) 90% RH or less (non-condensing) |