With this resistance meter, you can measure a broad range of resistance values to fit your applications. The meter is capable of gauging resistance from 10mΩ to 1,000MΩ.
With this resistance meter, you can measure a broad range of resistance values to fit your applications. The meter is capable of gauging resistance from 10mΩ to 1,000MΩ.
Covering a range of values from 10 mΩ to 1,000 MΩ, this Hioki RM3545 Resistance Meter delivers precise measurements of resistance. The meter is ideal for advanced research and production facilities, while the Offset Voltage Compensation (OVC) makes corrections for the effects of EMF for accurate results.
Features
Resistance Range | 10 mΩ to 1,000 MΩ range, 1,000 mΩ to 1,000 Ω (LP on) |
Measurement Accuracy | ±0.006% of reading ±0.001% full scale |
Testing Current | 1 A DC to 1 μA or less, 1 mA to 5 μA DC (LP on) |
Open-Terminal Voltage | 10 kΩ Range or More: 20 VDC, 1,000 Ω Range or Less: 5.5 VDC maximum, LP On: 20 mVDC maximum |
Temperature Measurement | 14 to 211.82°F (-10 to 99.9°C) with ±0.5°C accuracy (temperature sensor Z2001 and RM3545 combine accuracy), -147.82 to 1831.82°F (-99.9 to 999.9°C) analog input |
Measurement Speed | Fast (2.2 ms), Medium (50 Hz: 21 ms, 60 Hz: 18 ms), Slow1 (102 ms), Slow2 (202 ms) |
Functions | Temperature correction, temperature conversion, offset voltage compensation (OVC), comparator (ABS/ REF%), BIN, key-lock (OFF, menu lock, all lock), display digit count selection function (7- digit/ 6-digit/ 5-digit), automatic power supply frequency settings (AUTO/50 Hz/60 Hz), scaling, judgment sound setting, auto hold, averaging, statistical calculations, panel store/panel load, D/A output |
Interface | RS-232C, USB 2.0 |
Power Supply | 100 to 240 VAC, 50/60 Hz |
Rated Power Consumption | 40 VA |
Product Length | 12.07" (306.5 mm) |
Product Width | 8.46" (215 mm) |
Product Height | 3.15" (80 mm) |
Product Weight | 88.2 oz (2.5 kg) |
Resistance Range | 10 mΩ to 1,000 MΩ range, 1,000 mΩ to 1,000 Ω (LP on) |
Measurement Accuracy | ±0.006% of reading ±0.001% full scale |
Testing Current | 1 A DC to 1 μA or less, 1 mA to 5 μA DC (LP on) |
Open-Terminal Voltage | 10 kΩ Range or More: 20 VDC, 1,000 Ω Range or Less: 5.5 VDC maximum, LP On: 20 mVDC maximum |
Temperature Measurement | 14 to 211.82°F (-10 to 99.9°C) with ±0.5°C accuracy (temperature sensor Z2001 and RM3545 combine accuracy), -147.82 to 1831.82°F (-99.9 to 999.9°C) analog input |
Measurement Speed | Fast (2.2 ms), Medium (50 Hz: 21 ms, 60 Hz: 18 ms), Slow1 (102 ms), Slow2 (202 ms) |
Functions | Temperature correction, temperature conversion, offset voltage compensation (OVC), comparator (ABS/ REF%), BIN, key-lock (OFF, menu lock, all lock), display digit count selection function (7- digit/ 6-digit/ 5-digit), automatic power supply frequency settings (AUTO/50 Hz/60 Hz), scaling, judgment sound setting, auto hold, averaging, statistical calculations, panel store/panel load, D/A output |
Interface | RS-232C, USB 2.0 |
Power Supply | 100 to 240 VAC, 50/60 Hz |
Rated Power Consumption | 40 VA |
Product Length | 12.07" (306.5 mm) |
Product Width | 8.46" (215 mm) |
Product Height | 3.15" (80 mm) |
Product Weight | 88.2 oz (2.5 kg) |