Hioki SP7001-95 Non-Contact CAN Sensor, supports CAN FD/CAN signals, SP7001, SP9250, and SP7150 set

Model: SP7001-95

Hioki SP7001-95 Non-Contact CAN Sensor, supports CAN FD/CAN signals, SP7001, SP9250, and SP7150 set

Model: SP7001-95

The SP7001 is a CAN and CAN FD signal sensor that uses non-contact technology to accurately capture CAN bus signals necessary for vehicle and next generation equipment evaluation and development. Improve testing productivity and efficiency by eliminating the need to peel away cable insulation or use a sub-harness that is traditionally required to obtain signals.

The SP7001 is a CAN and CAN FD signal sensor that uses non-contact technology to accurately capture CAN bus signals necessary for vehicle and next generation equipment evaluation and development. Improve testing productivity and efficiency by eliminating the need to peel away cable insulation or use a sub-harness that is traditionally required to obtain signals.

Sale Price $3325.00 USD
Regular Price $3500.00 USD
Availability 2 to 3 Weeks
Quantity

Hioki SP7001-95 Offers

Features

  • The SP7001 Non-Contact CAN Sensor allows you to acquire CAN bus signals from outside the wire coating. CAN signals are the main control signals inside a car.
  • Until now, engineers needed to spend immense man hours to process the CAN bus wire. With the Non-contact CAN sensor, monitoring CAN data is easier than ever. Since wires remain undamaged, the CAN bus remains unaffected even during monitoring.
  • Acquire CAN FD/CAN data immediately, simply by pinching probes over wire insulation with one-hand
  • Eliminate concerns by using non-contact sensing technology
  • Use in a diverse array of development and evaluation applications that demand reliability

Hioki SP7001-95 Specifications

Detection method Capacitive-coupled signal detection
No bare-wire connections
Detectable cables AVS/AVSS-compliant cables, External diameter: 1.2 mm (0.05 in) to 2.0 mm (0.08 in)
Number of channels 1 CH (SP7150), 2 CH (SP7100)
Compatible communications speeds SP7001: CAN, CAN FD 125 kbit/s to 3 Mbit/s
SP7002: CAN 125 kbit/s to 1 Mbit/s
Total delay time 130 ns (typical)
CAN terminal resistance 60 Ω (typical), built-in
Signal output connector D-sub 9-pin female
Operating temperature, humidity Temperature: -40 °C to 85 °C (-40 °F to 185 °F)
Humidity: -40 °C to 60 °C (-40 °F to 140 °F), 80% RH or less (with no condensation), 60 °C to 85 °C (140 °F to 185 °F), 60% RH or less (with no condensation)
Power supply (1) When using the SP7001-95 or SP7150
- USB bus power (5 V DC), Maximum rated power: 1 VA
- Z1013 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 6 VA (including AC adapter), 1 VA (product only)

(2) When using the SP7001-90, SP7002-90, or SP7100
- Z1008 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 8 VA (including AC adapter), 3 VA (product only)
- External power supply: Rated supply voltage: 10 V to 30 V DC, Maximum rated power: 3 VA
Dimensions and mass SP7001, SP7002: 44 W × 85 H × 20 D mm (1.73 in. W × 3.35 in. H × 0.79 in. D), 180 g (6.35 oz.), Cable length: 2.5 m (8.20 ft.)

What's included with the Hioki SP7001-95

  • Non-Contact CAN Sensor
  • Quick Start Manual
  • Operating Precautions

Ask a question about Hioki SP7001-95 Non-Contact CAN Sensor, supports CAN FD/CAN signals, SP7001, SP9250, and SP7150 set

Customer Reviews for the Hioki SP7001-95

Hioki SP7001-95 Offers

Features

  • The SP7001 Non-Contact CAN Sensor allows you to acquire CAN bus signals from outside the wire coating. CAN signals are the main control signals inside a car.
  • Until now, engineers needed to spend immense man hours to process the CAN bus wire. With the Non-contact CAN sensor, monitoring CAN data is easier than ever. Since wires remain undamaged, the CAN bus remains unaffected even during monitoring.
  • Acquire CAN FD/CAN data immediately, simply by pinching probes over wire insulation with one-hand
  • Eliminate concerns by using non-contact sensing technology
  • Use in a diverse array of development and evaluation applications that demand reliability

Hioki SP7001-95 Specifications

Detection method Capacitive-coupled signal detection
No bare-wire connections
Detectable cables AVS/AVSS-compliant cables, External diameter: 1.2 mm (0.05 in) to 2.0 mm (0.08 in)
Number of channels 1 CH (SP7150), 2 CH (SP7100)
Compatible communications speeds SP7001: CAN, CAN FD 125 kbit/s to 3 Mbit/s
SP7002: CAN 125 kbit/s to 1 Mbit/s
Total delay time 130 ns (typical)
CAN terminal resistance 60 Ω (typical), built-in
Signal output connector D-sub 9-pin female
Operating temperature, humidity Temperature: -40 °C to 85 °C (-40 °F to 185 °F)
Humidity: -40 °C to 60 °C (-40 °F to 140 °F), 80% RH or less (with no condensation), 60 °C to 85 °C (140 °F to 185 °F), 60% RH or less (with no condensation)
Power supply (1) When using the SP7001-95 or SP7150
- USB bus power (5 V DC), Maximum rated power: 1 VA
- Z1013 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 6 VA (including AC adapter), 1 VA (product only)

(2) When using the SP7001-90, SP7002-90, or SP7100
- Z1008 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 8 VA (including AC adapter), 3 VA (product only)
- External power supply: Rated supply voltage: 10 V to 30 V DC, Maximum rated power: 3 VA
Dimensions and mass SP7001, SP7002: 44 W × 85 H × 20 D mm (1.73 in. W × 3.35 in. H × 0.79 in. D), 180 g (6.35 oz.), Cable length: 2.5 m (8.20 ft.)

What's included with the Hioki SP7001-95

  • Non-Contact CAN Sensor
  • Quick Start Manual
  • Operating Precautions

Ask a question about Hioki SP7001-95 Non-Contact CAN Sensor, supports CAN FD/CAN signals, SP7001, SP9250, and SP7150 set

Customer Reviews for the Hioki SP7001-95

More Hioki Products