MinIPAQ C230 is a universal, unisolated, 2-wire head-mounted transmitter for temperature measurements and other measurement applications. It’s robust design and high quality provide good performance and accuracy even under harsh conditions.
MinIPAQ C230 is a universal, unisolated, 2-wire head-mounted transmitter for temperature measurements and other measurement applications. It’s robust design and high quality provide good performance and accuracy even under harsh conditions.
The transmitter accepts inputs from several types of resistance thermometers (RTDs), thermocouple sensors (TCs), and linear resistance and mV signals. Configuration of the transmitter is easily done with the INOR Connect smartphone app, either wirelessly via NFC or via a connected Bluetooth® modem. Configuration can also be done via a PC with the Windows programme ConSoft.
Features
| Type | Universal digital head-mounted 2-wire signal transmitter |
| Input | Resistance (RTD), Thermocouples (TC), mV and Ω |
| Input Resistance, 2-, 3-, 4-wire connection | Pt10 to Pt1000, Ni100, Ni120, Ni1000 |
| Input Thermocouples | Type B, C, D, E, J, K, N, R, S, T |
| Input Mv | -10 to 1000 mV |
| Input Resistance, 2-, 3-, 4-wire connection | 0 to 4000 Ω (0-2000 ohm for 2-wire coupling) |
| Output | 4-20 mA, (temperature linear RTD and TC) , 2-wire loop powered |
| Output Signal and Sensor Failure | According to NAMUR NE43 |
| Galvanic Isolation | No, unisolated |
| Power Supply, polarity protected | 8 to 36 VDC |
| Typical Accuracy, (RTD) | Max. of ±0.15 K or ±0.15% of span |
| Typical Accuracy, TC type J and K | Max. of ±0.5 K or ±0.25% of span, ±1 K (CJC) |
| Long-Term Drift | Maximum ±0.05% of span per year |
| Vibration | IEC 60068-2-6, 10g |
| EMC | According to standards EN 61326-1 and EN 61326-2-3 |
| RoHS | Complies with the requirements of RoHS-directive |
| Configuration | ConSoft Windows software or INOR Connect smartphone app |
| Wireless Configuration | NFC and Bluetooth® * |
| Mounting | In connection-head according to DIN EN 50446 form B or larger |
| Type | Universal digital head-mounted 2-wire signal transmitter |
| Input | Resistance (RTD), Thermocouples (TC), mV and Ω |
| Input Resistance, 2-, 3-, 4-wire connection | Pt10 to Pt1000, Ni100, Ni120, Ni1000 |
| Input Thermocouples | Type B, C, D, E, J, K, N, R, S, T |
| Input Mv | -10 to 1000 mV |
| Input Resistance, 2-, 3-, 4-wire connection | 0 to 4000 Ω (0-2000 ohm for 2-wire coupling) |
| Output | 4-20 mA, (temperature linear RTD and TC) , 2-wire loop powered |
| Output Signal and Sensor Failure | According to NAMUR NE43 |
| Galvanic Isolation | No, unisolated |
| Power Supply, polarity protected | 8 to 36 VDC |
| Typical Accuracy, (RTD) | Max. of ±0.15 K or ±0.15% of span |
| Typical Accuracy, TC type J and K | Max. of ±0.5 K or ±0.25% of span, ±1 K (CJC) |
| Long-Term Drift | Maximum ±0.05% of span per year |
| Vibration | IEC 60068-2-6, 10g |
| EMC | According to standards EN 61326-1 and EN 61326-2-3 |
| RoHS | Complies with the requirements of RoHS-directive |
| Configuration | ConSoft Windows software or INOR Connect smartphone app |
| Wireless Configuration | NFC and Bluetooth® * |
| Mounting | In connection-head according to DIN EN 50446 form B or larger |