INOR C520XS HART Compatible Universal Dual-Input 2-Wire Transmitters, SIL 2 compatible, ATEX, IECEx

Model: C520XS | Order No: 70C520XS10

INOR C520XS HART Compatible Universal Dual-Input 2-Wire Transmitters, SIL 2 compatible, ATEX, IECEx

Model: C520XS | Order No: 70C520XS10

It features a universal, isolated, dual-input temperature transmitter with additional voltage and resistance input. The IPAQ C520N is approved for Non-Incendive use in Ex-Zone 2. C520X/C520XS are Intrinsically Safe versions for use in Ex-Zone 0, 1, and 2.

It features a universal, isolated, dual-input temperature transmitter with additional voltage and resistance input. The IPAQ C520N is approved for Non-Incendive use in Ex-Zone 2. C520X/C520XS are Intrinsically Safe versions for use in Ex-Zone 0, 1, and 2.

Your Price $575.00 USD
Availability 2 to 3 Weeks
Quantity

INOR C520XS Offers

These transmitters are compatible with the HART 6 protocol. Typical characteristics are the high accuracy, stability, and reliability combined with a robust housing.

Features

  • Universal, dual-input for RTD and T/C
  • SIL 2 compatible according to IEC 61508-2
  • 5 year guaranted stability
  • Withstands 10g vibrations
  • Complies with NAMUR NE 21, NE 43, NE 53, NE 89 and NE 107
  • EMC immunity according to Criteria A
  • Sensor Backup
  • Sensor Drift Monitoring
  • Sensor Isolation Monitoring
  • Sensor matching
  • 50 point customized linearization
  • Integrated in Emerson AMS and Siemens PDM systems

INOR C520XS Specifications

Type Head-mounted
Input RTD
Thermocouple
Universal
Input RTD Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10
Input Thermocouple Type B, C, D, E, J, K, N, R, S, T
Type of Transmitter Digital
Output 4-20 mA, HART®
Isolation Isolated
Measuring Channels 2 channels
Input Connections 2-, 3-, 4- wire connection
Power Supply IPAQ C520/C520S: 10 to 36 VDC; IPAQ C520X/C520XS: 10 to 30 VDC
Approvals ATEX, IECEx, SIL2
Typical Accuracy RTD: Max. of ±0.18°F (±0.1°C) or ±0.05% of span
TC: Typical ±0.05 of span
Quick Delivery Yes
Click here for complete specifications on the INOR C520XS

What's included with the INOR C520XS

  • INOR C520XS HART Compatible Universal Dual-Input 2-Wire Transmitters, SIL 2 compatible, ATEX, IECEx

Ask a question about INOR C520XS HART Compatible Universal Dual-Input 2-Wire Transmitters, SIL 2 compatible, ATEX, IECEx

Customer Reviews for the INOR C520XS

INOR C520XS Offers

These transmitters are compatible with the HART 6 protocol. Typical characteristics are the high accuracy, stability, and reliability combined with a robust housing.

Features

  • Universal, dual-input for RTD and T/C
  • SIL 2 compatible according to IEC 61508-2
  • 5 year guaranted stability
  • Withstands 10g vibrations
  • Complies with NAMUR NE 21, NE 43, NE 53, NE 89 and NE 107
  • EMC immunity according to Criteria A
  • Sensor Backup
  • Sensor Drift Monitoring
  • Sensor Isolation Monitoring
  • Sensor matching
  • 50 point customized linearization
  • Integrated in Emerson AMS and Siemens PDM systems

INOR C520XS Specifications

Type Head-mounted
Input RTD
Thermocouple
Universal
Input RTD Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10
Input Thermocouple Type B, C, D, E, J, K, N, R, S, T
Type of Transmitter Digital
Output 4-20 mA, HART®
Isolation Isolated
Measuring Channels 2 channels
Input Connections 2-, 3-, 4- wire connection
Power Supply IPAQ C520/C520S: 10 to 36 VDC; IPAQ C520X/C520XS: 10 to 30 VDC
Approvals ATEX, IECEx, SIL2
Typical Accuracy RTD: Max. of ±0.18°F (±0.1°C) or ±0.05% of span
TC: Typical ±0.05 of span
Quick Delivery Yes
Click here for complete specifications on the INOR C520XS

What's included with the INOR C520XS

  • INOR C520XS HART Compatible Universal Dual-Input 2-Wire Transmitters, SIL 2 compatible, ATEX, IECEx

Ask a question about INOR C520XS HART Compatible Universal Dual-Input 2-Wire Transmitters, SIL 2 compatible, ATEX, IECEx

Customer Reviews for the INOR C520XS