Track and record wet bulb temperature, as well as dew point, heat stress index, humidity, pressure (absolute), pressure trend, relative humidity and temperature in order to better understand the critical environmental conditions surrounding a fire. Wireless data connectivity allows for remote view of readings as well as hands-free automatic data upload.
Track and record wet bulb temperature, as well as dew point, heat stress index, humidity, pressure (absolute), pressure trend, relative humidity and temperature in order to better understand the critical environmental conditions surrounding a fire. Wireless data connectivity allows for remote view of readings as well as hands-free automatic data upload.
Kestrel DROP loggers are designed to be used anywhere you need to track environmental conditions. Each DROP measures just 1 x 1.8 x 2.4 inches (24 x 46 mm x 60 mm) and weighs just 1.2 ounces (34 grams).
DROPs are Powered by the Kestrel Connect App, Download it HereFeatures
D1 (0710) |
D2 (0720) |
D3 (0730) |
|
| Temperature | x |
x |
x |
| Humidity | x |
x |
|
| Heat Index | x |
x |
|
| Dew Point Temperature | x |
x |
|
| Station Pressure | x |
||
| Density Altitude | x |
||
| Pressure Trend | x |
||
| Available Colours: Red, Blue, Tan | x |
x |
x |
| Temperature | Range: 14 to 131°F (-10 to 55°C) Accuracy: ±0.9°F (±0.5°C) Resolution: 0.1°F (0.1°C) |
| Humidity | Range: 10 to 90% RH, 77°F (25°C) Accuracy: ±2% RH, ± 1.5 mbar at 25°C Resolution: 0.1% RH |
| Pressure | Range: 77°F (25°C), 700 to 1100 mbar (20.67 to 32.48 inHg) Accuracy: ±0.044 inHg at 77°F (25°C), 20.67 to 32.48 inHg Resolution: 0.1 mbar (0.01 inHg) |
| Dew Point | Range: 10 to 90% RH at 77°F (25°C) Accuracy: ±3°F (±1.8°C) Resolution: 0.1°F (0.1°C) |
| Heat Index | Range: 10 to 90% RH at 77°F (25°C) Accuracy: ±5°F (±2.6°C) Resolution: 0.1°F (0.1°C) |
| Density Altitude | Range: 10 to 90% RH over 50 to 131°F (10 to 55°C), 700 to 1100 mbar (20.67 to 32.48 inHg) Accuracy: ±8' (±250 m) Resolution: 0.1' (0.1 m) |
| Operational Range | Temperature: 0 to 140°F (-18 to 60°C) Humidity: 0 to 100% RH Pressure: 10 to 1200 hPa |
| Dimensions | 2.4 x 1.8 x 0.9" (6 x 4.5 x 2.3 cm) |
| Weight | 1.2 oz (34 g) |
| Temperature | Range: 14 to 131°F (-10 to 55°C) Accuracy: ±0.9°F (±0.5°C) Resolution: 0.1°F (0.1°C) |
| Humidity | Range: 10 to 90% RH, 77°F (25°C) Accuracy: ±2% RH, ± 1.5 mbar at 25°C Resolution: 0.1% RH |
| Pressure | Range: 77°F (25°C), 700 to 1100 mbar (20.67 to 32.48 inHg) Accuracy: ±0.044 inHg at 77°F (25°C), 20.67 to 32.48 inHg Resolution: 0.1 mbar (0.01 inHg) |
| Dew Point | Range: 10 to 90% RH at 77°F (25°C) Accuracy: ±3°F (±1.8°C) Resolution: 0.1°F (0.1°C) |
| Heat Index | Range: 10 to 90% RH at 77°F (25°C) Accuracy: ±5°F (±2.6°C) Resolution: 0.1°F (0.1°C) |
| Density Altitude | Range: 10 to 90% RH over 50 to 131°F (10 to 55°C), 700 to 1100 mbar (20.67 to 32.48 inHg) Accuracy: ±8' (±250 m) Resolution: 0.1' (0.1 m) |
| Operational Range | Temperature: 0 to 140°F (-18 to 60°C) Humidity: 0 to 100% RH Pressure: 10 to 1200 hPa |
| Dimensions | 2.4 x 1.8 x 0.9" (6 x 4.5 x 2.3 cm) |
| Weight | 1.2 oz (34 g) |