Megger 1005-261 HV Test Lead Set, 15m, 15kV, Large Insulated Clips, Set of 3

Model: 1005-261 | UPC: 5036175229965

Megger 1005-261 HV Test Lead Set, 15m, 15kV, Large Insulated Clips, Set of 3

Model: 1005-261 | UPC: 5036175229965

The large insulated clips are to be used with 15 kV instruments only, including model MIT1525. The design of the lead sets is intended to facilitate connection to a variety of de-energized systems for the purpose of making insulation resistance measurements.

The large insulated clips are to be used with 15 kV instruments only, including model MIT1525. The design of the lead sets is intended to facilitate connection to a variety of de-energized systems for the purpose of making insulation resistance measurements.

Your Price $530.00 USD
Availability 2 to 3 Weeks
Quantity

Megger 1005-261 Offers

Features

  • Large range to suit all applications
  • Unique locking HV insulated plugs
  • None detachable clips for safety with capacitance
  • Screened options for high noise environments
  • High quality silicon double insulated cable

Safety Warnings

  • The circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. Make sure the circuit is not re-energised whilst the instrument is connected.
  • Circuit connections must not be touched during an insulation test.
  • After completing test, capacitive circuits must be completely discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharge, until required for use. This is to guard against any stored dielectric absorption charge subsequently being released thereby raising the voltage to potentially dangerous levels.
  • Test leads, including crocodile clips, must be in good order, clean, dry and with no broken or cracked insulation.
  • The lead set should not be used if any part of it is damaged.
  • These accessories are not designed to provide full levels of safety isolation to the operator if touched. The required physical dimensions would render this impractical. Safe working practices must be used.

Application Notes

These clips are designed for clamping on larger diameter test pieces. The insulation is designed only to protect the user from the output of Megger 15 kV (set below 10 kV) insulation resistance testers.

The clips cannot in any circumstance be relied on to protect the user from live systems above 1000 V a.c. in a CAT IV environment.

Megger 1005-261 Specifications

Dimensions 208 (L) X 240 (closed) mm
Jaw opening 28 mm diameter max
Number in set 3
Double insulation rating 7.5 kV d.c.
Basic insulation rating 15 kV d.c
Safety specification IEC61010-31:2008 The clips are therefore touch proof when closed
CAT rating 1000 V a.c CAT IV
Cable details 15 kV test leads
Lead length 15 m
Insulation rating 15 kV d.c. (Marked on cable)
Cable type Flexible dual insulated silicon (inner insulation layer coloured white to highlight damage)
Click here for complete specifications on the Megger 1005-261

What's included with the Megger 1005-261

  • Megger 1005-261 HV Test Lead Set, 15m, 15kV, Large Insulated Clips, Set of 3

Ask a question about Megger 1005-261 HV Test Lead Set, 15m, 15kV, Large Insulated Clips, Set of 3

Customer Reviews for the Megger 1005-261

Megger 1005-261 Offers

Features

  • Large range to suit all applications
  • Unique locking HV insulated plugs
  • None detachable clips for safety with capacitance
  • Screened options for high noise environments
  • High quality silicon double insulated cable

Safety Warnings

  • The circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. Make sure the circuit is not re-energised whilst the instrument is connected.
  • Circuit connections must not be touched during an insulation test.
  • After completing test, capacitive circuits must be completely discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharge, until required for use. This is to guard against any stored dielectric absorption charge subsequently being released thereby raising the voltage to potentially dangerous levels.
  • Test leads, including crocodile clips, must be in good order, clean, dry and with no broken or cracked insulation.
  • The lead set should not be used if any part of it is damaged.
  • These accessories are not designed to provide full levels of safety isolation to the operator if touched. The required physical dimensions would render this impractical. Safe working practices must be used.

Application Notes

These clips are designed for clamping on larger diameter test pieces. The insulation is designed only to protect the user from the output of Megger 15 kV (set below 10 kV) insulation resistance testers.

The clips cannot in any circumstance be relied on to protect the user from live systems above 1000 V a.c. in a CAT IV environment.

Megger 1005-261 Specifications

Dimensions 208 (L) X 240 (closed) mm
Jaw opening 28 mm diameter max
Number in set 3
Double insulation rating 7.5 kV d.c.
Basic insulation rating 15 kV d.c
Safety specification IEC61010-31:2008 The clips are therefore touch proof when closed
CAT rating 1000 V a.c CAT IV
Cable details 15 kV test leads
Lead length 15 m
Insulation rating 15 kV d.c. (Marked on cable)
Cable type Flexible dual insulated silicon (inner insulation layer coloured white to highlight damage)