A rugged, portable 10 kV insulation resistance tester designed for diagnostic testing and maintenance of high-voltage electrical equipment. It includes advanced features like PI Predictor™ and RE>Act™ mode for more reliable insulation assessment.
A rugged, portable 10 kV insulation resistance tester designed for diagnostic testing and maintenance of high-voltage electrical equipment. It includes advanced features like PI Predictor™ and RE>Act™ mode for more reliable insulation assessment.
The Megger range of 5, 10 and 15 kV insulation testers are known worldwide for their rugged dependability, long service life and accurate, reliable measurements. The extensive range of models means that there will always be a perfect match for your requirements. One common feature across the whole range is the Megger, ‘no compromise’ approach to safety. The Megger level of safety will always go further than simply complying with the relevant safety standards.
Features
| AC voltage (auto ranging) | 90 to 264 V rms, 50/60 Hz, 100 VA |
| Battery voltage | 10.8 V, 5.2Ah, 56.16 Wh meets IEC 62133-2:2017 |
| Battery life | 4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ loa |
| Auto power off | Instrument turns off after a few minutes if not in use to conserve battery life |
| 30 min quick charge | 1 hour operation at 5 kV with a 100 MΩ load |
| Battery charge time | 2.5 hours deep discharge 2 hours normal discharge |
| Test voltage | 250 V, 500 V, 1000 V, 2500 V, 5000 V, 10000 V |
| Lock test voltage | 40 V to 1 kV in 10 V steps 1 kV to 5 kV in 25 V steps |
| Test voltage accuracy | +4%, -0%, ±10 V nominal test voltage at 1 GΩ load 32 to 86°F (0 to 30°C) |
| Resistance range | 10 kΩ to 15 TΩ at 5 kV |
Re| Reabsorption current measurement nominal accuracy. |
Operational up to 30 V external applied. |
| Resistance accuracy (per test voltage) | 10 kV: ±5% to 2 TΩ; ±20% to 20 TΩ 5000 V: ±5% to 1 TΩ; ±20% to 10 TΩ 2500 V: ±5% to 500 GΩ; ±20% to 5 TΩ 1000 V: ±5% to 200 GΩ; ±20% to 2 TΩ 500 V: ±5% to 100 GΩ; ±20% to 1 TΩ |
| Guard terminal performance | When measuring an insulation resistance of 100 GΩ at 5000 V the tester can guard out current IG at least 5000 times the insulation test current IL with a maximum additional resistance error of 1%. |
| Display range analogue | 100 kΩ to 10 TΩ |
| Display range digital | 10 kΩ to 35 TΩ |
| Short circuit/charge current | 1 mA, 2 mA, 3 mA 4 mA, 5 mA, 6 mA (6 mA from internal battery and mains supply) |
| Insulation test Alarm | 100 kΩ to 10 GΩ |
| Capacitor charge (at 6 mA) (with AC or battery) | <1.5 μF to 5 kV, <2.7 s/μF to 10 kV, < 4 s/μF to 15 kV |
| Capacitor discharge | <250 ms/μF to discharge from 10 kV to 50 V |
| Capacitance range (with test voltage set above 500 V) | 10 nF to 25 μF |
| Capacitance measurement accuracy | 10 nF to 10 μF: ±10% ±5 nF |
| Current range 0.01 mA to 6 mA | 1 mA, 2 mA, 3 mA 4 mA, 5 mA, 6 mA (6 mA from internal battery and mains supply) |
| Current accuracy | ±5% ±0.2 nA at all voltages (68°F (20°C)) |
| Interference | 8 mA from 2560 V to 10 kV |
| Software 4 filter settings | 10 s, 30 s, 100 s, 200 s |
| Voltmeter range | 30 to 660 V AC or DC 45 to 65 Hz |
| Voltmeter accuracy | ±3%, ±3 V |
| Timer range | Up to 99 minutes 59 seconds 15 second minimum setting |
| Memory capacity | 11 hrs logging at 5 sec intervals |
| Test modes | IR, IR(t), DAR, PI, SV, DD, PDC, ramp test |
| Interface | USB type B (device) Bluetooth® Class 2 |
| Real time output | (V, I, R) readings at a rate of 1 Hz |
| Remote control | Remote control via USB cable only (requires RC dongle to be in position) |
| Maximum altitude | 9842' (3000 m) |
| Operating temperature range | -4 to 122 °F (-20 to 50 °C) |
| Storage temperature range | -13 to 149 °F (-25 to 65 °C) |
| Humidity | 90% RH non-condensing at 104°F (40°C) |
| IP rating | IP65 (lid closed) IP40 (lid open) |
| Safety | Meets the requirements of IEC 61010-1 CAT IV 600 V to 3000 m (5 kV, 10 kV) CATIV 1000 V to 4000 m (15 kV) |
| EMC | Meets the requirements of IEC61326-1 |
| Dimensions | 11.2 x 7.1 x 12.4" (285 x 181 x 315 mm) |
| Weight | 9.9 lbs (4.5 kg) |
| AC voltage (auto ranging) | 90 to 264 V rms, 50/60 Hz, 100 VA |
| Battery voltage | 10.8 V, 5.2Ah, 56.16 Wh meets IEC 62133-2:2017 |
| Battery life | 4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ loa |
| Auto power off | Instrument turns off after a few minutes if not in use to conserve battery life |
| 30 min quick charge | 1 hour operation at 5 kV with a 100 MΩ load |
| Battery charge time | 2.5 hours deep discharge 2 hours normal discharge |
| Test voltage | 250 V, 500 V, 1000 V, 2500 V, 5000 V, 10000 V |
| Lock test voltage | 40 V to 1 kV in 10 V steps 1 kV to 5 kV in 25 V steps |
| Test voltage accuracy | +4%, -0%, ±10 V nominal test voltage at 1 GΩ load 32 to 86°F (0 to 30°C) |
| Resistance range | 10 kΩ to 15 TΩ at 5 kV |
Re| Reabsorption current measurement nominal accuracy. |
Operational up to 30 V external applied. |
| Resistance accuracy (per test voltage) | 10 kV: ±5% to 2 TΩ; ±20% to 20 TΩ 5000 V: ±5% to 1 TΩ; ±20% to 10 TΩ 2500 V: ±5% to 500 GΩ; ±20% to 5 TΩ 1000 V: ±5% to 200 GΩ; ±20% to 2 TΩ 500 V: ±5% to 100 GΩ; ±20% to 1 TΩ |
| Guard terminal performance | When measuring an insulation resistance of 100 GΩ at 5000 V the tester can guard out current IG at least 5000 times the insulation test current IL with a maximum additional resistance error of 1%. |
| Display range analogue | 100 kΩ to 10 TΩ |
| Display range digital | 10 kΩ to 35 TΩ |
| Short circuit/charge current | 1 mA, 2 mA, 3 mA 4 mA, 5 mA, 6 mA (6 mA from internal battery and mains supply) |
| Insulation test Alarm | 100 kΩ to 10 GΩ |
| Capacitor charge (at 6 mA) (with AC or battery) | <1.5 μF to 5 kV, <2.7 s/μF to 10 kV, < 4 s/μF to 15 kV |
| Capacitor discharge | <250 ms/μF to discharge from 10 kV to 50 V |
| Capacitance range (with test voltage set above 500 V) | 10 nF to 25 μF |
| Capacitance measurement accuracy | 10 nF to 10 μF: ±10% ±5 nF |
| Current range 0.01 mA to 6 mA | 1 mA, 2 mA, 3 mA 4 mA, 5 mA, 6 mA (6 mA from internal battery and mains supply) |
| Current accuracy | ±5% ±0.2 nA at all voltages (68°F (20°C)) |
| Interference | 8 mA from 2560 V to 10 kV |
| Software 4 filter settings | 10 s, 30 s, 100 s, 200 s |
| Voltmeter range | 30 to 660 V AC or DC 45 to 65 Hz |
| Voltmeter accuracy | ±3%, ±3 V |
| Timer range | Up to 99 minutes 59 seconds 15 second minimum setting |
| Memory capacity | 11 hrs logging at 5 sec intervals |
| Test modes | IR, IR(t), DAR, PI, SV, DD, PDC, ramp test |
| Interface | USB type B (device) Bluetooth® Class 2 |
| Real time output | (V, I, R) readings at a rate of 1 Hz |
| Remote control | Remote control via USB cable only (requires RC dongle to be in position) |
| Maximum altitude | 9842' (3000 m) |
| Operating temperature range | -4 to 122 °F (-20 to 50 °C) |
| Storage temperature range | -13 to 149 °F (-25 to 65 °C) |
| Humidity | 90% RH non-condensing at 104°F (40°C) |
| IP rating | IP65 (lid closed) IP40 (lid open) |
| Safety | Meets the requirements of IEC 61010-1 CAT IV 600 V to 3000 m (5 kV, 10 kV) CATIV 1000 V to 4000 m (15 kV) |
| EMC | Meets the requirements of IEC61326-1 |
| Dimensions | 11.2 x 7.1 x 12.4" (285 x 181 x 315 mm) |
| Weight | 9.9 lbs (4.5 kg) |