Megger DET4TC2 Kit (1000-404)

Model: DET4TC2+Kit

Megger DET4TC2 Kit (1000-404)-


More Megger Products

Ask an Expert

Megger DET4TC2 Kit (1000-404)

Model: DET4TC2+Kit

DET4TC2+Clamps plus Professional Ground Testing Kit (6320-245).

DET4TC2+Clamps plus Professional Ground Testing Kit (6320-245).

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Megger DET4T2 Series 4-Terminal Digital Ground Testers-

Megger DET4T2 Series 4-Terminal Digital Ground Testers

Model: DET4TC2 | Order No: DET4TC2 Series

Unstoppable with a wide range of capabilities, this ground testing instrument family is perfect for greater testing flexibility. From stakeless capabilities to Attached Rod Technique (ART), everything you need for proper ground testing is at your disposal with practical accessories to improve performance.


Not what you're looking for? Let’s do a search and help you find what you need.


Megger DET4TC2+Kit Offers

The Megger DET4TC2KIT comes with the ICLAMP, VCLAMP, Hard Pack Case, Leads, Stakes, and 4 terminal adaptors, plus the Professional Ground Kit (6320-245)!

  • Offers a speciatist earth testing kit packed in two field cases
  • 2, 3 and 4 point testing at the turn of a switch
  • Attached Rod Technique (ART)
  • Stakeless measurements
  • User selectable noise suppression and output voltage
  • Simple one button operation
  • Automatic circuit checking
  • Extended measurement range 200 kΩ
  • Backlit display
  • Weather and dust proof to IP54
  • Packed in tough carry case
  • Delivered with a FREE calibration certificate

Applications

Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environmental conditions and facility expansion can create different ground system needs.

The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.

The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an ac signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.

Grounding electrodes from simple to complex systems can be tested, including:

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger DET4TC2+Kit Specifications

Resistance Range 0.01 Ω to 20 kΩ
Resistance Accuracy 2% ±3 digits
Earth Voltage Range 0 to 100 V AC
Earth Voltage Accuracy 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check Automatic
Noise Rejection 40 V pk to pk
2-Wire Test Yes
3-Wire Test Yes
4-Wire Test Yes
Display LCD
Battery Type 8 x 1.5 V AA cells
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)

What's included with the Megger DET4TC2+Kit

  • Megger DET4TC2 Kit (1000-404)

Selection Guide DET4TD2 DET4TR2 DET4TC2 DET4TCR2
Tests 2-Pole Measurement
3-Pole Measurement
4-Pole Measurement
Soil Resistivity
ART (Attached Rod Technique) Capability
Stakeless (Clamp-on) Measurement Capability
Resistance Range 0.01 to 20,000 Ω 0.01 to 200,000 Ω
Ground Voltage Range 0 to 100 V
Ground Current Range (with ICLAMP) Capability 0.5 mA to 19.9 A
Output Selectable Voltage (25/50 V)
Test Frequency 128 Hz 94, 105, 111, 128 Hz
Power Supply Alkaline Batteries
Rechargeable Batteries
Noise Rejection 40 V Peak-to-Peak
Safety Rating CAT IV 100 V
Ingress Protection Rated to IP54
Included Accessories Hard Carry Case
Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes
Certificate of Calibration
Warranty 2 Year

Webinar: How Ground Testing Keeps Us Safe with Megger


Ground systems are integral because of the protection and safety it offers to the public and the electrical equipment we use every day. These systems need to be monitored and maintained to ensure their reliability during normal conditions, unexpected faults, and to prevent cascading failures.

We teamed up with Megger for this short webinar on Ground Testing, where we cover:
• How Ground Testing keeps us safe
• Ground Testing theory
• Step Potential and Touch Potential
• Soil Resistivity – testing for new installations
• Electrode & Earth Resistance – testing for maintenance
• Attached Rod Technique – testing without disconnecting
• Stakeless Electrode Test – benefits of clamps
• Testing in electrically noisy environments

Ask a question about Megger DET4TC2 Kit (1000-404)

Customer Reviews for the Megger DET4TC2+Kit

Megger DET4TC2+Kit Offers

The Megger DET4TC2KIT comes with the ICLAMP, VCLAMP, Hard Pack Case, Leads, Stakes, and 4 terminal adaptors, plus the Professional Ground Kit (6320-245)!

  • Offers a speciatist earth testing kit packed in two field cases
  • 2, 3 and 4 point testing at the turn of a switch
  • Attached Rod Technique (ART)
  • Stakeless measurements
  • User selectable noise suppression and output voltage
  • Simple one button operation
  • Automatic circuit checking
  • Extended measurement range 200 kΩ
  • Backlit display
  • Weather and dust proof to IP54
  • Packed in tough carry case
  • Delivered with a FREE calibration certificate

Applications

Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environmental conditions and facility expansion can create different ground system needs.

The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.

The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an ac signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.

Grounding electrodes from simple to complex systems can be tested, including:

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger DET4TC2+Kit Specifications

Resistance Range 0.01 Ω to 20 kΩ
Resistance Accuracy 2% ±3 digits
Earth Voltage Range 0 to 100 V AC
Earth Voltage Accuracy 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check Automatic
Noise Rejection 40 V pk to pk
2-Wire Test Yes
3-Wire Test Yes
4-Wire Test Yes
Display LCD
Battery Type 8 x 1.5 V AA cells
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)

What's included with the Megger DET4TC2+Kit

  • Megger DET4TC2 Kit (1000-404)

Selection Guide DET4TD2 DET4TR2 DET4TC2 DET4TCR2
Tests 2-Pole Measurement
3-Pole Measurement
4-Pole Measurement
Soil Resistivity
ART (Attached Rod Technique) Capability
Stakeless (Clamp-on) Measurement Capability
Resistance Range 0.01 to 20,000 Ω 0.01 to 200,000 Ω
Ground Voltage Range 0 to 100 V
Ground Current Range (with ICLAMP) Capability 0.5 mA to 19.9 A
Output Selectable Voltage (25/50 V)
Test Frequency 128 Hz 94, 105, 111, 128 Hz
Power Supply Alkaline Batteries
Rechargeable Batteries
Noise Rejection 40 V Peak-to-Peak
Safety Rating CAT IV 100 V
Ingress Protection Rated to IP54
Included Accessories Hard Carry Case
Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes
Certificate of Calibration
Warranty 2 Year

Webinar: How Ground Testing Keeps Us Safe with Megger


Ground systems are integral because of the protection and safety it offers to the public and the electrical equipment we use every day. These systems need to be monitored and maintained to ensure their reliability during normal conditions, unexpected faults, and to prevent cascading failures.

We teamed up with Megger for this short webinar on Ground Testing, where we cover:
• How Ground Testing keeps us safe
• Ground Testing theory
• Step Potential and Touch Potential
• Soil Resistivity – testing for new installations
• Electrode & Earth Resistance – testing for maintenance
• Attached Rod Technique – testing without disconnecting
• Stakeless Electrode Test – benefits of clamps
• Testing in electrically noisy environments

Ask a question about Megger DET4TC2 Kit (1000-404)

Customer Reviews for the Megger DET4TC2+Kit

More Megger Products