The Megger DET4TC2KIT comes with the ICLAMP, VCLAMP, Hard Pack Case, Leads, Stakes, and 4 terminal adaptors, plus the Professional Ground Kit (6320-245)!
Applications
Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environmental conditions and facility expansion can create different ground system needs.
The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.
The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an ac signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.
Grounding electrodes from simple to complex systems can be tested, including:
| Resistance Range | 0.01 Ω to 20 kΩ |
| Resistance Accuracy | 2% ±3 digits |
| Earth Voltage Range | 0 to 100 V AC |
| Earth Voltage Accuracy | 2% ±2 V |
| C Spike Check | Automatic |
| P Spike Check | Automatic |
| Noise Check | Automatic |
| Noise Rejection | 40 V pk to pk |
| 2-Wire Test | Yes |
| 3-Wire Test | Yes |
| 4-Wire Test | Yes |
| Display | LCD |
| Battery Type | 8 x 1.5 V AA cells |
| Temperature Range | Operating: 5 to 131°F (-15 to 55°C) Storage: -40 to 158°F (-40 to 70°C) |
| Safety | EN61010-1 CAT IV 100 V |
| Ingress Protection | IP54 |
| Dimensions | 8 x 5.7 x 3.2" (203 x 148 x 78 mm) |
| Weight | 2.20 lbs (1 kg) |
| Selection Guide | DET4TD2 | DET4TR2 | DET4TC2 | DET4TCR2 | |
|---|---|---|---|---|---|
| Tests | 2-Pole Measurement | ||||
| 3-Pole Measurement | |||||
| 4-Pole Measurement | |||||
| Soil Resistivity | |||||
| ART (Attached Rod Technique) Capability | |||||
| Stakeless (Clamp-on) Measurement Capability | |||||
| Resistance Range | 0.01 to 20,000 Ω | 0.01 to 200,000 Ω | |||
| Ground Voltage Range | 0 to 100 V | ||||
| Ground Current Range (with ICLAMP) Capability | 0.5 mA to 19.9 A | ||||
| Output | Selectable Voltage (25/50 V) | ||||
| Test Frequency | 128 Hz | 94, 105, 111, 128 Hz | |||
| Power Supply | Alkaline Batteries | ||||
| Rechargeable Batteries | |||||
| Noise Rejection | 40 V Peak-to-Peak | ||||
| Safety Rating | CAT IV 100 V | ||||
| Ingress Protection | Rated to IP54 | ||||
| Included Accessories | Hard Carry Case | ||||
| Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes | |||||
| Certificate of Calibration | |||||
| Warranty | 2 Year | ||||
| Resistance Range | 0.01 Ω to 20 kΩ |
| Resistance Accuracy | 2% ±3 digits |
| Earth Voltage Range | 0 to 100 V AC |
| Earth Voltage Accuracy | 2% ±2 V |
| C Spike Check | Automatic |
| P Spike Check | Automatic |
| Noise Check | Automatic |
| Noise Rejection | 40 V pk to pk |
| 2-Wire Test | Yes |
| 3-Wire Test | Yes |
| 4-Wire Test | Yes |
| Display | LCD |
| Battery Type | 8 x 1.5 V AA cells |
| Temperature Range | Operating: 5 to 131°F (-15 to 55°C) Storage: -40 to 158°F (-40 to 70°C) |
| Safety | EN61010-1 CAT IV 100 V |
| Ingress Protection | IP54 |
| Dimensions | 8 x 5.7 x 3.2" (203 x 148 x 78 mm) |
| Weight | 2.20 lbs (1 kg) |
| Selection Guide | DET4TD2 | DET4TR2 | DET4TC2 | DET4TCR2 | |
|---|---|---|---|---|---|
| Tests | 2-Pole Measurement | ||||
| 3-Pole Measurement | |||||
| 4-Pole Measurement | |||||
| Soil Resistivity | |||||
| ART (Attached Rod Technique) Capability | |||||
| Stakeless (Clamp-on) Measurement Capability | |||||
| Resistance Range | 0.01 to 20,000 Ω | 0.01 to 200,000 Ω | |||
| Ground Voltage Range | 0 to 100 V | ||||
| Ground Current Range (with ICLAMP) Capability | 0.5 mA to 19.9 A | ||||
| Output | Selectable Voltage (25/50 V) | ||||
| Test Frequency | 128 Hz | 94, 105, 111, 128 Hz | |||
| Power Supply | Alkaline Batteries | ||||
| Rechargeable Batteries | |||||
| Noise Rejection | 40 V Peak-to-Peak | ||||
| Safety Rating | CAT IV 100 V | ||||
| Ingress Protection | Rated to IP54 | ||||
| Included Accessories | Hard Carry Case | ||||
| Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes | |||||
| Certificate of Calibration | |||||
| Warranty | 2 Year | ||||