Measures both dew point and moisture content, this dew-point transmitter has -112 to 68°F (-80 to 20°C) dp range and a standard HDPE guard for protection against fine particulates with <10 µm size. In addition, it is simple to install and available with a wide range of process connections and electrical connectors.
Measures both dew point and moisture content, this dew-point transmitter has -112 to 68°F (-80 to 20°C) dp range and a standard HDPE guard for protection against fine particulates with <10 µm size. In addition, it is simple to install and available with a wide range of process connections and electrical connectors.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Features
Applications
| Measurement Range | -148 to 68°F (-100 to 20°C) dew point |
| Accuracy | ±3.6°F (±2°C) dew point |
| Response Time | 5 mins to T95 (dry to wet) |
| Repeatability | 0.9°F (0.5°C) dew point |
| Calibration | Traceable 13-point calibration certificate |
| Output Signal | 4 to 20 mA (2-wire connection, current source); User configurable over range |
| Supply Voltage | 12 to 28 V DC |
| Temperature | Operating: -40 to 140°F (-40 to 60°C) Compensated temperature range: -4 to 122°F (-20 to 50°C) Storage: -40 to 140°F (-40 to 60°C) |
| Operating Pressure | 45 MPa (450 barg/6527 psig) maximum |
| Flow Rate | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion |
| Ingress Protection | IP66 in accordance with standard BS EN 60529:1992; NEMA 4 protection in accordance with standard NEMA 250–2003 |
| Process Connection | ⅝"; - 18 UNF |
| Housing Material | 316 stainless steel |
| Dimensions | MiniDIN 43650 form C L=5.2 x Ø1.77"; (132 x Ø45 mm) (with connector cable) |
| Weight | 0.33 lbs (150 g) |
| Measurement Range | -148 to 68°F (-100 to 20°C) dew point |
| Accuracy | ±3.6°F (±2°C) dew point |
| Response Time | 5 mins to T95 (dry to wet) |
| Repeatability | 0.9°F (0.5°C) dew point |
| Calibration | Traceable 13-point calibration certificate |
| Output Signal | 4 to 20 mA (2-wire connection, current source); User configurable over range |
| Supply Voltage | 12 to 28 V DC |
| Temperature | Operating: -40 to 140°F (-40 to 60°C) Compensated temperature range: -4 to 122°F (-20 to 50°C) Storage: -40 to 140°F (-40 to 60°C) |
| Operating Pressure | 45 MPa (450 barg/6527 psig) maximum |
| Flow Rate | 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion |
| Ingress Protection | IP66 in accordance with standard BS EN 60529:1992; NEMA 4 protection in accordance with standard NEMA 250–2003 |
| Process Connection | ⅝"; - 18 UNF |
| Housing Material | 316 stainless steel |
| Dimensions | MiniDIN 43650 form C L=5.2 x Ø1.77"; (132 x Ø45 mm) (with connector cable) |
| Weight | 0.33 lbs (150 g) |