Featuring smart App connectivity with an intuitive, advanced user interface, this combustion analyzer also pairs with myNAVAC™ and measureQuick® via Bluetooth for wireless monitoring, data tracking, and professional reporting. Additionally, it offers a 5" (12.7 cm) color HD touchscreen and built-in differential pressure and draft measurement. This value added kit includes the REED R9300 Combustible Gas Leak Detector and REED R5030 Clamp Meter for FREE.
Featuring smart App connectivity with an intuitive, advanced user interface, this combustion analyzer also pairs with myNAVAC™ and measureQuick® via Bluetooth for wireless monitoring, data tracking, and professional reporting. Additionally, it offers a 5" (12.7 cm) color HD touchscreen and built-in differential pressure and draft measurement. This value added kit includes the REED R9300 Combustible Gas Leak Detector and REED R5030 Clamp Meter for FREE.
Features
Large HD Touchscreen
Built-In Pressure and Draft
Smart App Connectivity
Professional Reporting
Full Combustion Analysis
Field-Ready Design
REED R9300 Combustible Gas Leak Detector
This combustible gas leak detector is capable of detecting a number of gases including: natural gas, methane, benzene, ethane, propane, butane, acetone, alcohol, ammonia, gasoline, jet fuel, industrial solvents, lacquer, paint thinner and naptha. The R9300 is alarm is set at 10% (LEL) for methane.
Features
REED R5030 True RMS AC/DC Clamp Meter with NCV, 500 A, ±2.8%
This compact autoranging True RMS clamp meter is capable of measuring AC/DC current and voltage, resistance, frequency, capacitance, duty cycle and temperature. Featuring a 50,000 count backlit LCD display, double molded plastic housing, the R5030 includes diode check and continuity functions and a non-contact voltage detector built into the clamp tip.
Features
Applications
| Combustion Analyzer | |
| Bluetooth Range | ≤164' (≤50 m) |
| Pump Flow Rate | >0.088 gal/min (400 mL/min) |
| Screen | 5-inch (12.7 cm) 720*1280 touch screen |
| Environmental Conditions | Operating temperature: 23 to 113°F (-5 to 45°C) Operating humidity: <90% RH Storage temperature: −4 to 122°F (-20 to 50°C) |
| Power | Type-C charging |
| Battery Life | 6 hours (pump running 100% of the time) |
| Charging Time | <3 hours |
| Dimensions | 9.25 x 4.33 x 2.32" (235 x 110 x 58.9 mm) Case: 20.94 x 13.50 x 5.24" (532 x 343 x 133 mm) |
| Weight | Device: 1.65 lbs (749 g) Measuring gun: 1.21 lbs (550 g) |
| Performance Analysis | |
| Calculated CO2 | Range: 0 to CO2maximum vol% Accuracy: 0.1 vol% Resolution: ±0.3 vol% Response time: <40 seconds |
| Combustion Efficiency | Range: 0 to 100% Accuracy: Calculated Resolution: 0.10% |
| Excess Air | Range: 0 to 999% Accuracy: Calculated Resolution: 0.10% |
| Perte de gaz de combustion (qA) | Range: 0 to 100% Accuracy: Calculated Resolution: 0.10% |
| O2 Sensor | Range: 0 to 25 vol% Accuracy: 0.1 vol% Resolution: ±0.3 vol% Response time: <30 seconds |
| CO Sensor | Range: 0 to 4000 ppm Accuracy: ±10 ppm: 0 to 200 ppm ±5% reading: 201 to 2000 ppm ±10% reading: 2001 to 4000 ppm Overload: 10000 ppm carbon monoxide Resolution: 1 ppm Response time: <90 seconds |
| Differential Pressure Sensor | Range: 0 to ±40 inWC Accuracy: ±0.2 inWC: 0 to ±20 inWC ±1% reading: ±20.1 to 40.0 inWC Overload: 11.6 psig (321 inWC) Resolution: 0.01 inWC Response time: <10 seconds |
| Flue Gas Temperature Sensor | Range: 32 to 1112°F (0 to 600°C) Accuracy: ±2.5°F: 32 to 212°F ±3.6°F or 1.5% reading: 213 to 1112°F ±1.4°C: 0 to 100°C ±2.0°C or 1.5% reading: 101 to 600°C Resolution: 0.1°F (0.1°C) Response time: <30 seconds |
| Ambient Temperature Sensor (one-time air temperature) | Range: -4 to 248°F (-20 to 120°C) Accuracy: ±3.6°F (±2.0°C) Resolution: 0.1°F (0.1°C) Response time: <30 seconds |
Featuring smart App connectivity with an intuitive, advanced user interface, this combustion analyzer also pairs with myNAVAC™ and measureQuick® via Bluetooth for wireless monitoring, data tracking, and professional reporting. Additionally, it offers a 5" (12.7 cm) color HD touchscreen and built-in differential pressure and draft measurement.
User adjustable sensitivity wheel and earphone jack for loud environments.
Compact AC/DC clamp meter with backlit display, built-in non-contact voltage (NCV) detector and contact thermometer.
| Combustion Analyzer | |
| Bluetooth Range | ≤164' (≤50 m) |
| Pump Flow Rate | >0.088 gal/min (400 mL/min) |
| Screen | 5-inch (12.7 cm) 720*1280 touch screen |
| Environmental Conditions | Operating temperature: 23 to 113°F (-5 to 45°C) Operating humidity: <90% RH Storage temperature: −4 to 122°F (-20 to 50°C) |
| Power | Type-C charging |
| Battery Life | 6 hours (pump running 100% of the time) |
| Charging Time | <3 hours |
| Dimensions | 9.25 x 4.33 x 2.32" (235 x 110 x 58.9 mm) Case: 20.94 x 13.50 x 5.24" (532 x 343 x 133 mm) |
| Weight | Device: 1.65 lbs (749 g) Measuring gun: 1.21 lbs (550 g) |
| Performance Analysis | |
| Calculated CO2 | Range: 0 to CO2maximum vol% Accuracy: 0.1 vol% Resolution: ±0.3 vol% Response time: <40 seconds |
| Combustion Efficiency | Range: 0 to 100% Accuracy: Calculated Resolution: 0.10% |
| Excess Air | Range: 0 to 999% Accuracy: Calculated Resolution: 0.10% |
| Perte de gaz de combustion (qA) | Range: 0 to 100% Accuracy: Calculated Resolution: 0.10% |
| O2 Sensor | Range: 0 to 25 vol% Accuracy: 0.1 vol% Resolution: ±0.3 vol% Response time: <30 seconds |
| CO Sensor | Range: 0 to 4000 ppm Accuracy: ±10 ppm: 0 to 200 ppm ±5% reading: 201 to 2000 ppm ±10% reading: 2001 to 4000 ppm Overload: 10000 ppm carbon monoxide Resolution: 1 ppm Response time: <90 seconds |
| Differential Pressure Sensor | Range: 0 to ±40 inWC Accuracy: ±0.2 inWC: 0 to ±20 inWC ±1% reading: ±20.1 to 40.0 inWC Overload: 11.6 psig (321 inWC) Resolution: 0.01 inWC Response time: <10 seconds |
| Flue Gas Temperature Sensor | Range: 32 to 1112°F (0 to 600°C) Accuracy: ±2.5°F: 32 to 212°F ±3.6°F or 1.5% reading: 213 to 1112°F ±1.4°C: 0 to 100°C ±2.0°C or 1.5% reading: 101 to 600°C Resolution: 0.1°F (0.1°C) Response time: <30 seconds |
| Ambient Temperature Sensor (one-time air temperature) | Range: -4 to 248°F (-20 to 120°C) Accuracy: ±3.6°F (±2.0°C) Resolution: 0.1°F (0.1°C) Response time: <30 seconds |
Featuring smart App connectivity with an intuitive, advanced user interface, this combustion analyzer also pairs with myNAVAC™ and measureQuick® via Bluetooth for wireless monitoring, data tracking, and professional reporting. Additionally, it offers a 5" (12.7 cm) color HD touchscreen and built-in differential pressure and draft measurement.
User adjustable sensitivity wheel and earphone jack for loud environments.
Compact AC/DC clamp meter with backlit display, built-in non-contact voltage (NCV) detector and contact thermometer.