Measures pH, mV, conductivity, TDS, salinity and temperature. Calibrate pH with up to 6 points from USA, NIST, DIN, PWB, and custom pH buffer sets.
Measures pH, mV, conductivity, TDS, salinity and temperature. Calibrate pH with up to 6 points from USA, NIST, DIN, PWB, and custom pH buffer sets.
Features
| pH | |
| Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration | 6 points: USA, NIST, DIN, PWB & custom buffers |
| mV | |
| Range | ±2000 mV |
| Resolution | 0.1 to 1 mV |
| Accuracy | ±0.2 ±2 LSD or ±5% rdg.; whichever is greater |
| Calibration | ±200 mV |
| Conductivity | |
| Range | 0 to 200 mS |
| Resolution | 0.01 µS to 0.1 mS |
| Accuracy | ±1% full scale |
| Calibration | Auto/manual; one point per range |
| TDS | |
| Range | 0 to 200 ppt |
| Resolution | 0.01 ppm to 0.1 ppt |
| Accuracy | ±1% full scale |
| Calibration | Auto/manual; one point per range |
| Temperature | |
| Range | -10.0 to 110.0°C |
| Resolution | 0.1°C |
| Accuracy | ±0.5°C |
| Calibration | Offset 0.1°C increments |
| Temp. Compensation | Automatic or manual |
| General Specifications | |
| Power Supply | 2 AA batteries, or optional power adapter |
| Dimensions | 7 7/8" x 3 1/8" x 2 1/4" (20 x 8.3 x 5.7 cm) |
| Weight | 1.4 lb (0.6 kg) |
Click on a category to view a selection of compatible accessories with the OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes.
| pH | |
| Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration | 6 points: USA, NIST, DIN, PWB & custom buffers |
| mV | |
| Range | ±2000 mV |
| Resolution | 0.1 to 1 mV |
| Accuracy | ±0.2 ±2 LSD or ±5% rdg.; whichever is greater |
| Calibration | ±200 mV |
| Conductivity | |
| Range | 0 to 200 mS |
| Resolution | 0.01 µS to 0.1 mS |
| Accuracy | ±1% full scale |
| Calibration | Auto/manual; one point per range |
| TDS | |
| Range | 0 to 200 ppt |
| Resolution | 0.01 ppm to 0.1 ppt |
| Accuracy | ±1% full scale |
| Calibration | Auto/manual; one point per range |
| Temperature | |
| Range | -10.0 to 110.0°C |
| Resolution | 0.1°C |
| Accuracy | ±0.5°C |
| Calibration | Offset 0.1°C increments |
| Temp. Compensation | Automatic or manual |
| General Specifications | |
| Power Supply | 2 AA batteries, or optional power adapter |
| Dimensions | 7 7/8" x 3 1/8" x 2 1/4" (20 x 8.3 x 5.7 cm) |
| Weight | 1.4 lb (0.6 kg) |
Click on a category to view a selection of compatible accessories with the OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes.