Omega ADR-J-G-1/2-96-2 Thermocouple Probe with removable bayonet locking cap and male quick disconnect OST, type J grounded, 32 to 1328°F

Model: ADR-J-G-1/2-96-2

Omega ADR-J-G-1/2-96-2 Thermocouple Probe with removable bayonet locking cap and male quick disconnect OST, type J grounded, 32 to 1328°F-

Image is for reference only, refer to product info for complete details.


Downloads: datasheet

Omega ADR-J-G-1/2-96-2 Thermocouple Probe with removable bayonet locking cap and male quick disconnect OST, type J grounded, 32 to 1328°F

Model: ADR-J-G-1/2-96-2

Designed for adjustable-depth temperature measurement, this type J adjustable-depth thermocouple probe measures up to 1328°F (720°C) from a 304 SS sheath. Moreover, it has a 0.28" (7.11 mm) diameter, a 0.5" (12.7 mm) probe length, a 96" (2.4 m) flexible armor, a grounded junction, an locking fitting over flexible armor, a removable bayonet locking cap, and male quick disconnect (ost).

Designed for adjustable-depth temperature measurement, this type J adjustable-depth thermocouple probe measures up to 1328°F (720°C) from a 304 SS sheath. Moreover, it has a 0.28" (7.11 mm) diameter, a 0.5" (12.7 mm) probe length, a 96" (2.4 m) flexible armor, a grounded junction, an locking fitting over flexible armor, a removable bayonet locking cap, and male quick disconnect (ost).

Your Price $109.61 USD
Availability 2 to 3 Weeks
Quantity

OMEGA ADR-J-G-1/2-96-2 Offers

This unique thermocouple is easy to adjust to ANY immersion depth into wells (but NOTE: this probe cannot be immersed in liquids). Adjustable depth eliminates the need to stock a variety of fixed depth immersion probes. The locking cap can be positioned anywhere along the flexible armor and obtains its locking force from a unique spring-action catch. The welded stainless steel tipped probe is held against the bottom of the well by compression of the armor.

Style ADR has a removable locking fitting and requires a BTA adapter. This style is ideal for installations where the mounting surface is under a layer of insulation, or where the locking cap must be removable.

Features

  • Locking fitting freely adjustable over flexible armor
  • Spring-action catch holds probe firmly in place
  • Removable locking cap with bayonet fitting connects with a twist
  • Standard-size connectors

Applications

  • Adjustable-depth immersion temperature measurement
  • Plastic processing machinery temperature monitoring
  • Thermowell and variable-depth temperature sensing
  • Industrial process temperature measurement
  • Equipment and machinery temperature monitoring

OMEGA ADR-J-G-1/2-96-2 Specifications

Thermocouple Type J
Sheath Material 304 SS
Junction Type Grounded
Mounting Adjustable locking fitting over flexible armor
Locking Cap Removable bayonet
Wire Gauge 20 AWG
Termination Male quick disconnect (OST)
Dimensions Probe diameter: 0.28" (7.11 mm)
Probe length: 0.5" (12.7 mm)
Armor cable length: 96" (2.4 m)
Click here for complete specifications on the OMEGA ADR-J-G-1/2-96-2

What's included with the OMEGA ADR-J-G-1/2-96-2

  • Omega ADR-J-G-1/2-96-2 Thermocouple Probe with removable bayonet locking cap and male quick disconnect OST, type J grounded, 32 to 1328°F

Ask a question about Omega ADR-J-G-1/2-96-2 Thermocouple Probe with removable bayonet locking cap and male quick disconnect OST, type J grounded, 32 to 1328°F

Customer Reviews for the OMEGA ADR-J-G-1/2-96-2

OMEGA ADR-J-G-1/2-96-2 Offers

This unique thermocouple is easy to adjust to ANY immersion depth into wells (but NOTE: this probe cannot be immersed in liquids). Adjustable depth eliminates the need to stock a variety of fixed depth immersion probes. The locking cap can be positioned anywhere along the flexible armor and obtains its locking force from a unique spring-action catch. The welded stainless steel tipped probe is held against the bottom of the well by compression of the armor.

Style ADR has a removable locking fitting and requires a BTA adapter. This style is ideal for installations where the mounting surface is under a layer of insulation, or where the locking cap must be removable.

Features

  • Locking fitting freely adjustable over flexible armor
  • Spring-action catch holds probe firmly in place
  • Removable locking cap with bayonet fitting connects with a twist
  • Standard-size connectors

Applications

  • Adjustable-depth immersion temperature measurement
  • Plastic processing machinery temperature monitoring
  • Thermowell and variable-depth temperature sensing
  • Industrial process temperature measurement
  • Equipment and machinery temperature monitoring

OMEGA ADR-J-G-1/2-96-2 Specifications

Thermocouple Type J
Sheath Material 304 SS
Junction Type Grounded
Mounting Adjustable locking fitting over flexible armor
Locking Cap Removable bayonet
Wire Gauge 20 AWG
Termination Male quick disconnect (OST)
Dimensions Probe diameter: 0.28" (7.11 mm)
Probe length: 0.5" (12.7 mm)
Armor cable length: 96" (2.4 m)
Click here for complete specifications on the OMEGA ADR-J-G-1/2-96-2

What's included with the OMEGA ADR-J-G-1/2-96-2

  • Omega ADR-J-G-1/2-96-2 Thermocouple Probe with removable bayonet locking cap and male quick disconnect OST, type J grounded, 32 to 1328°F

Ask a question about Omega ADR-J-G-1/2-96-2 Thermocouple Probe with removable bayonet locking cap and male quick disconnect OST, type J grounded, 32 to 1328°F

Customer Reviews for the OMEGA ADR-J-G-1/2-96-2

More OMEGA Products