This RTD simulator sources one or multiple RTD curves to calibrate RTD instruments at ±(0.015% reading + 0.05 Ω) accuracy. It supports 10 curves from 100 to 1000 Ω with over-voltage protection to 60 V DC. It suits RTD instrument and transmitter calibration.
This RTD simulator sources one or multiple RTD curves to calibrate RTD instruments at ±(0.015% reading + 0.05 Ω) accuracy. It supports 10 curves from 100 to 1000 Ω with over-voltage protection to 60 V DC. It suits RTD instrument and transmitter calibration.
RTD simulator that sources one or multiple RTD curves for calibrating RTD instruments. It offers over-voltage protection to 60 V DC and runs on four AA batteries.
Features
Applications
| Series | CL510A |
| Type | RTD simulator |
| Type | RTD simulator |
| RTD curves | 10 RTD curves (100 Ω and 1000 Ω) |
| Accuracy | ±(0.015% reading + 0.05 Ω) |
| Resistance range | 100 to 1000 Ω |
| Overvoltage protection | 60 V DC |
| Battery | Four AA, 50 hour life |
| Function | Source one or multiple RTD curves; calibrate directly in temperature (°C or °F) |
| Source Accuracy | From 1 to 10.2 mA External Excitation Current: ±(0.015% of rdg + 0.05 Ω); Below 1 mA of External Excitation Current: ±(0.015% of rdg + 0.01 mV/mA excitation current + 0.05 Ω) |
| Allowable Excitation Current Range, Steady or Pulsed/Intermittent | <410 Ω: 10.2 mA maximum; 410 to 4001 Ω: 1 mA maximum |
| Pulsed Excitation Current Compatibility | DC to 0.01 second pulse width |
| Temperature Drift | ±0.05 Ω/°C |
| Adjustment | Adjustable digital potentiometer "DIAL", set any value to within 0.1° |
| Protection Against Misconnection | Over-voltage protection to 60 V DC (rated for 30 sec) |
| Display | High contrast graphic liquid crystal display, LED backlighting for use in low lit areas |
| Low Battery | Low battery indication with nominal 1 hour of operation left |
| Operating Temperature Range | -13 to 140°F (-25 to 60°C) |
| Relative Humidity Range | 10% ≤RH ≤90%: 32 to 95°F (0 to 35°C), non-condensing; ≤70%: 95 to 140°F (35 to 60°C), non-condensing |
| Nominal rating | Rated from a nominal 73°F (23°C), 70% RH |
| Size | 126 L x 69 W x 1.77" (45 mm) H (4.96 x 2.73 x 1.79" (12.6 x 6.9 x 4.5 cm)) |
| Batteries | 4" (10.2 cm)AA" alkaline 1.5 V (included) |
| Standard Battery Life | 50 hr |
| Included | 4" (10.2 cm)AA" alkaline batteries, NIST certificate of calibration (no points), RTD wire kit with 2 red and 2 black leads with retractable shield banana plugs and spade lugs, and operator's manual |
| Dimensions | 4.96 x 2.73 x 1.79" (12.6 x 6.9 x 4.5 cm) |
| Weight | 8.4 oz (0.24 kg) |
| Series | CL510A |
| Type | RTD simulator |
| Type | RTD simulator |
| RTD curves | 10 RTD curves (100 Ω and 1000 Ω) |
| Accuracy | ±(0.015% reading + 0.05 Ω) |
| Resistance range | 100 to 1000 Ω |
| Overvoltage protection | 60 V DC |
| Battery | Four AA, 50 hour life |
| Function | Source one or multiple RTD curves; calibrate directly in temperature (°C or °F) |
| Source Accuracy | From 1 to 10.2 mA External Excitation Current: ±(0.015% of rdg + 0.05 Ω); Below 1 mA of External Excitation Current: ±(0.015% of rdg + 0.01 mV/mA excitation current + 0.05 Ω) |
| Allowable Excitation Current Range, Steady or Pulsed/Intermittent | <410 Ω: 10.2 mA maximum; 410 to 4001 Ω: 1 mA maximum |
| Pulsed Excitation Current Compatibility | DC to 0.01 second pulse width |
| Temperature Drift | ±0.05 Ω/°C |
| Adjustment | Adjustable digital potentiometer "DIAL", set any value to within 0.1° |
| Protection Against Misconnection | Over-voltage protection to 60 V DC (rated for 30 sec) |
| Display | High contrast graphic liquid crystal display, LED backlighting for use in low lit areas |
| Low Battery | Low battery indication with nominal 1 hour of operation left |
| Operating Temperature Range | -13 to 140°F (-25 to 60°C) |
| Relative Humidity Range | 10% ≤RH ≤90%: 32 to 95°F (0 to 35°C), non-condensing; ≤70%: 95 to 140°F (35 to 60°C), non-condensing |
| Nominal rating | Rated from a nominal 73°F (23°C), 70% RH |
| Size | 126 L x 69 W x 1.77" (45 mm) H (4.96 x 2.73 x 1.79" (12.6 x 6.9 x 4.5 cm)) |
| Batteries | 4" (10.2 cm)AA" alkaline 1.5 V (included) |
| Standard Battery Life | 50 hr |
| Included | 4" (10.2 cm)AA" alkaline batteries, NIST certificate of calibration (no points), RTD wire kit with 2 red and 2 black leads with retractable shield banana plugs and spade lugs, and operator's manual |
| Dimensions | 4.96 x 2.73 x 1.79" (12.6 x 6.9 x 4.5 cm) |
| Weight | 8.4 oz (0.24 kg) |