Made for equalizing pressure across enclosure walls, this vent plug threads into a PG-29 entry and seals with an included gasket and union nut. Its UL94 V-0 plastic body is rated to IP55 and measures 66 mm (2.6") by 31 mm (1.2"). Works great for pressure compensation and condensation control in sealed electrical enclosures.
Made for equalizing pressure across enclosure walls, this vent plug threads into a PG-29 entry and seals with an included gasket and union nut. Its UL94 V-0 plastic body is rated to IP55 and measures 66 mm (2.6") by 31 mm (1.2"). Works great for pressure compensation and condensation control in sealed electrical enclosures.
It has become more and more important to provide a protected enclosure environment for valuable and crucial electrical and electronic components. In a tightly closed enclosure, pressure differentials can occur during extreme temperature variations, such as day/night operation. When this occurs, the risk of dust and humidity being absorbed into the control panel increases dramatically.
The specially designed pressure compensation plug DA084 permits a controlled change in pressure. It can be installed easily in any enclosure. Because of the pressure compensation plug's high degree of protection, the protection type of the enclosure will not be affected.
Features
Applications
| Mounting | PG 29 thread with union nut |
| Material | Plastic according to UL94 V-0 |
| Air interface | Approx. 2.8 in² (7 cm²) |
| Fitting position | Variable |
| Operating/Storage temperature | -49 to 158°F (-45 to 70°C) |
| Installation | Make cut-out 1.5" + 0.03" (37 + 1 mm) diameter in enclosure wall and mount pressure compensation device with nut. Sealing gasket must be put in place on the outer side panel of the enclosure. |
| Packing unit | 1 piece |
| Dimensions | 2.6" (66 mm) diameter x 1.2" (31 mm) Cut-out diameter: 1.4" (37 mm) 0.6" (16 mm) |
| Weight | 0.14 lb (62 g) (31 g/piece) |
| Mounting | PG 29 thread with union nut |
| Material | Plastic according to UL94 V-0 |
| Air interface | Approx. 2.8 in² (7 cm²) |
| Fitting position | Variable |
| Operating/Storage temperature | -49 to 158°F (-45 to 70°C) |
| Installation | Make cut-out 1.5" + 0.03" (37 + 1 mm) diameter in enclosure wall and mount pressure compensation device with nut. Sealing gasket must be put in place on the outer side panel of the enclosure. |
| Packing unit | 1 piece |
| Dimensions | 2.6" (66 mm) diameter x 1.2" (31 mm) Cut-out diameter: 1.4" (37 mm) 0.6" (16 mm) |
| Weight | 0.14 lb (62 g) (31 g/piece) |