Made for conditioning process loops, this DIN-rail signal conditioner accepts a 0 to 50 V DC or 0 to 50 mA process signal. It runs on a DC supply and rescales the input to a standard process current or voltage output. Works great for isolating and transmitting signals from process voltage and current loops to PLCs and process instrumentation.
Made for conditioning process loops, this DIN-rail signal conditioner accepts a 0 to 50 V DC or 0 to 50 mA process signal. It runs on a DC supply and rescales the input to a standard process current or voltage output. Works great for isolating and transmitting signals from process voltage and current loops to PLCs and process instrumentation.
The DMD4380 accepts a dc voltage or current input and provides an optically isolated dc voltage or current output that is linear to the input. It provides filtering, amplifies, and converts the input signal to the selected dc voltage or current output that you select.
The 3-way 1200V isolation eliminates ground loops, common mode voltages and greatly reduces noise pick-up. The power supplies can also be wired to sink or source which allows the DMD4380 to be used with any combination of powered or unpowered mA inputs and powered or unpowered mA outputs including passive mA devices.
Features such as red and green LEDs that vary in intensity to show input and output activity and an output test button help make set-up and troubleshooting fast and easy.
Features
Applications
| Input ranges | Field selectable ranges via switch settings |
| Input range, voltage | 0-10 mVdc to 0-50 Vdc |
| Input range, bipolar voltage | ±50 mVdc to ±10 Vdc |
| Input range, current | 0-200 uAdc to 0-50 mAdc |
| Input impedance, voltage | 1 MΩ minimum |
| Input impedance, current | 50 Ω typical |
| Voltage burden | 1 Vdc at 20 mA |
| Input loop power supply | 15 Vdc ±10%, regulated, 25 mAdc; max ripple, less than 10 mV RMS; may be selectively wired for sinking or sourcing |
| Output ranges | Switch selectable, field rangeable |
| Output range, voltage (10 mA maximum) | 0-1 to 0-10 Vdc |
| Output range, bipolar voltage (10 mA maximum) | ±5 to ±10 Vdc |
| Output range, current | 0-2 mA to 0-25 mA |
| Compliance, drive at 20 mA | 20 V, 1000 Ω drive |
| Output offset | ±100% of span in 15% increments |
| Output linearity | Better than ±0.1% of span |
| Output zero and span | Multi-turn potentiometers to compensate for load and lead variations, ±15% of span adjustment range typical |
| Output loop power supply | 20 Vdc nominal, regulated, 25 mAdc; max ripple, less than 10 mV RMS; may be selectively wired for sinking or sourcing |
| Output ripple | <10 mV rms |
| Function test button | Sets output to test level when pressed; adjustable 0 to 100% of span via potentiometer. Factory default is approx. 50% of span |
| Response time | 70 ms typical |
| Common mode rejection | 120 db minimum |
| Isolation | 1200 Vrms minimum, 3-way isolation, power to input, power to output and input to output |
| Operating temperature range | 14 to 140°F (-10 to 60°C) |
| Thermal stability | Better than ±0.02% of span per °C |
| Mounting | Mounts to standard 35 mm DIN rail |
| Environmental protection | IP40 |
| Connections | Four 4-terminal removable connectors 14 AWG max wire size |
| Power input | Low Voltage Option: 9 to 30 Vdc or 10 to 32 Vac |
| Dimensions | 0.89 x 4.62 x 4.81" (22.5 W x 117 H x 122 mm D) height includes connectors |
| Weight | 5.3 oz (150 g) |
| Input ranges | Field selectable ranges via switch settings |
| Input range, voltage | 0-10 mVdc to 0-50 Vdc |
| Input range, bipolar voltage | ±50 mVdc to ±10 Vdc |
| Input range, current | 0-200 uAdc to 0-50 mAdc |
| Input impedance, voltage | 1 MΩ minimum |
| Input impedance, current | 50 Ω typical |
| Voltage burden | 1 Vdc at 20 mA |
| Input loop power supply | 15 Vdc ±10%, regulated, 25 mAdc; max ripple, less than 10 mV RMS; may be selectively wired for sinking or sourcing |
| Output ranges | Switch selectable, field rangeable |
| Output range, voltage (10 mA maximum) | 0-1 to 0-10 Vdc |
| Output range, bipolar voltage (10 mA maximum) | ±5 to ±10 Vdc |
| Output range, current | 0-2 mA to 0-25 mA |
| Compliance, drive at 20 mA | 20 V, 1000 Ω drive |
| Output offset | ±100% of span in 15% increments |
| Output linearity | Better than ±0.1% of span |
| Output zero and span | Multi-turn potentiometers to compensate for load and lead variations, ±15% of span adjustment range typical |
| Output loop power supply | 20 Vdc nominal, regulated, 25 mAdc; max ripple, less than 10 mV RMS; may be selectively wired for sinking or sourcing |
| Output ripple | <10 mV rms |
| Function test button | Sets output to test level when pressed; adjustable 0 to 100% of span via potentiometer. Factory default is approx. 50% of span |
| Response time | 70 ms typical |
| Common mode rejection | 120 db minimum |
| Isolation | 1200 Vrms minimum, 3-way isolation, power to input, power to output and input to output |
| Operating temperature range | 14 to 140°F (-10 to 60°C) |
| Thermal stability | Better than ±0.02% of span per °C |
| Mounting | Mounts to standard 35 mm DIN rail |
| Environmental protection | IP40 |
| Connections | Four 4-terminal removable connectors 14 AWG max wire size |
| Power input | Low Voltage Option: 9 to 30 Vdc or 10 to 32 Vac |
| Dimensions | 0.89 x 4.62 x 4.81" (22.5 W x 117 H x 122 mm D) height includes connectors |
| Weight | 5.3 oz (150 g) |