Omega DP606A Series Temperature Panel Meter, 2x relay output, 9 to 36 V DC

Model: DP606A-DC

Omega DP606A Series Temperature Panel Meter, 2x relay output, 9 to 36 V DC

Model: DP606A-DC

Built for process measurement and control, this temperature panel meter is supplied with 9 to 36 V DC Supply, 36 V DC Power & 2x Relay O/P. It has display of 4-digit, 7-segment LED; red, 0.83" (21 mm). It also suits industrial control panels.

Built for process measurement and control, this temperature panel meter is supplied with 9 to 36 V DC Supply, 36 V DC Power & 2x Relay O/P. It has display of 4-digit, 7-segment LED; red, 0.83" (21 mm). It also suits industrial control panels.

Your Price $1206.55 USD
Availability 2 to 3 Weeks
Quantity

OMEGA DP606A-DC Offers

The DP606A/DP612A Display Meter offers a flexible, easy to use 6 or 12 zone, 4 digit temperature and process measurement solution in a rugged 1/4 DIN Aluminum housing. Selectable configuration eliminates the need for jumpers. The DP606A supports 6 independent zones (3 wire RTD limited to 6 zones on all models).

The DP606A and DP612A Series is our newest line of affordable multi-channel panel meters. These models offer increased accuracy, wider operating temperatures and increased flexibility over the CN606 and CN612 models that they replace.

All zones are scanned at a 400 ms rate. The display shows the reading of each zone sequentially. High and low Alarms with SPDT relay outputs are available for monitoring and alarm purposes.

The input, power and communications are also now isolated allowing for easier deployment and more reliable operation. The rugged extruded aluminum 1/4 DIN case combines with the improved isolation to provide an extremely durable product.

These meters can read up to 12 sensors and include user selectable RS232 or RS485 communications using Modbus(R). Two user configurable Alarm relays are standard on all models.

The universal input allows user selection between thermocouple (9 types), RTD 2-wire, RTD 3-wire, 4 to 20 mA and 1000 mV input options. These input selections are firmware selectable through the front panel buttons or Modbus serial commands.

Note: While the inputs are universal and can be changed via firmware (no dip switches), all 6 or 12 inputs on a given unit must be set to the same type of input for operation.

Features

  • Flexible, easy to use 6 zone, 4 digit temperature and process measurement solution in a rugged 1/4 DIN aluminum housing
  • Universal TC, RTD and Process Inputs Firmware Selectable
  • Selectable configuration eliminates the need for jumpers
  • User Programmable Alarms Individually Settable per Channel
  • All zones are scanned at a 400 MS rate; the display shows the reading of each zone sequentially
  • Adjustable Scan Time: 400 ms Scan Rate per Channel
  • High and low alarms with spdt relay outputs are available for monitoring and alarm purposes
  • 2 User Assignable Alarm Relays
  • Universal input supports 9 thermocouple types (j, k, t, e, r, s, b, c, and n), 2 or 3 wire rtds (pt 100, ni 120, cu 10), DC voltage (0-1 v DC), or DC current (0 to 24 mA)
  • RS232/RS485 Communications
  • Independent alarms are available for each zone, configurable for above (hi), below (lo) or hi/lo triggering
  • Password Protection
  • User selectable rs232 or rs485 serial port interface is standard on all models and uses the modbus rtu protocol
  • Universal AC power supply accepts 90 to 240 v AC; the isolated DC power option accepts 9 to 36 v DC
  • A security password can be used to prevent front panel tampering of the configuration

Applications

  • Multi-zone temperature monitoring
  • OEM instrumentation temperature monitoring
  • Process measurement and control
  • Automotive and aerospace test stand data acquisition
  • Thermocouple and RTD monitoring
  • Factory automation process monitoring
  • Industrial control panels
  • Power generation plant monitoring
  • Laboratory measurement
  • Multi-channel thermocouple and RTD temperature measurement

OMEGA DP606A-DC Specifications

Series DP606A Series
No. of zones 6 or 12 (RTD 3 wire 6 channels for all models)
Type temperature panel meter
Display 15 mm 7-segment LED
Supply voltage 9 V DC to 36 V DC Supply
Display time 1 to 99 s
Scan time 400 ms
Output type 36 V DC Power & 2x Relay O/P
Input types TC: J, K, T, E, R, S, B, C, N
RTD: 2 or 3 wire (PT100, 0.00385; CU10, 0.00427; NI120, 0.00672)
Process: 4 to 20 mA, 0 to 1 V
Display 4-digit, 7-segment LED; red, 0.83" (21 mm)
Resolution 1°, 1 mV, 0.01 mA
Input Types 9 thermocouple types (J, K, T, E, R, S, B, C, and N), 2 or 3 wire RTDs (Pt 100, Ni 120, Cu 10), DC voltage (0-1 V DC), or DC current (0 to 24 mA)
ADC 24-bit Sigma Delta
Number of Zones 6 independent zones (3 wire RTD limited to 6 zones)
Communications RS232 and RS485 (user selectable) up to 115.2k baud, Modbus protocol (RTU)
Scan Rate 400 ms
Isolation per 1 min, power to alarm relay 2.3k Vac (3.2k Vdc)
Line Voltage/Power 120/240 V AC, 50/60 Hz, 3 W maximum
Isolation per 1 min, power to serial 2.3k Vac (3.2k Vdc)
Low-Voltage/Power Option 9 to 36 V DC, 3 W maximum
Isolation per 1 min, input to serial 500 Vac (720 Vdc)
Communications Selectable RS232 / RS485, Modbus RTU
Alarm relays De-energizes on alarm; latching or non-latching; high, low or hi/low
Protection NEMA-1/Type 1 front bezel
Operating temp -4 to 158°F (-20 to 70°C)
Process Voltage Accuracy ± 1 mV (0 to 1000 mV)
Storage temp -40 to 185°F (-40 to 85°C)
Process Current Accuracy ± 10 μA (0 to 24.00 mA)
Panel cutout 1/4 DIN 3.6 x 3.6" (92 x 92 mm)
Panel Cutout 1/4 DIN, 3.62 x 3.62" (92 x 92 mm)
Min rear panel depth 5.5" (140 mm)
Pollution Degree 2
ECCN EAR99
Altitude Up to 2000 meters
Safety 2014/35/EU
Alarm Relays AC Power Option 2x SPDT, 240 V AC, 5 A Load
EMC 2014/30/EU
Alarm Relays DC Power Option 2x SPDT, 36 V DC, 3 A Load
RoHS 2011/65/EU
Operating Environmental Conditions -4 to 158°F (-20 to 70°C), 90% RH non-condensing
UL file no. E209855, UL/cUL Listed
Storage Environmental Conditions -40 to 185°F (-40 to 85°C), 90% RH non-condensing
Power DC
Input Accuracy, Type J -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 2192°F (0 to 1200°C) ±1.0°C
Zones 6
Input Accuracy, Type K -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to -2438°F (0 to -1372°C) ±1.0°C (CHROMEGA-ALOMEGA)
Input power 9 to 36 Vdc, 3 watts maximum
Input Accuracy, Type T -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 752°F (0 to 400°C) ±1.0°C (Copper-Constantan)
Isolation per 1 min, power to input 1.5k Vdc
Input Accuracy, Type E -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 1832°F (0 to 1000°C) ±1.0°C (CHROMEGA-Constantan)
Alarm relays rating 36 Vdc max, 3A max load
Input Accuracy, Type R -58 to 32°F (-50 to 0°C) ±1.0°C (25°C); 32 to 3250°F (0 to 1788°C) ±1.0°C (Pt/13%Rh-Pt)
Dimensions 3.7 x 3.7 x 5.3" (95 L x 95 W x 135 Dia mm)
Input Accuracy, Type S -58 to 32°F (-50 to 0°C) ±1.0°C (25°C); 32 to 3214°F (0 to 1768°C) ±1.0°C (Pt/10%Rh-Pt)
Weight 26 oz (725 g)
Input Accuracy, Type B 302 to 1292°F (150 to 700°C) ±1.0°C (25°C); 1292 to 3308°F (700 to 1820°C) ±1.0°C (30%Rh-Pt/6%Rh-Pt)
Input Accuracy, Type C 5%Re-W/26%Re-W 32 to 4208°F (0 to 2320°C) ±1.0°C (25°C)
Input Accuracy, Type N -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 2372°F (0 to 1300°C) ±1.0°C (Nicrosil-Nisil)
Input Accuracy, RTD Pt Pt, 0.00385, 100 Ω, 2/3 Wire, -328 to 1562°F (-200 to 850°C) ±1.0°C
Input Accuracy, RTD Cu Cu, 0.00427, 10 Ω, 2/3 Wire, -328 to 500°F (-200 to 260°C) ±1.0°C
Input Accuracy, RTD Ni Ni, 0.00672, 120 Ω, 2/3 Wire, -112 to 500°F (-80 to 260°C) ±1.0°C
Absolute Maximum Input 3.3 V (Process Voltage) or 30mA (Process Current)
External Fuse Required Time-Delay UL 248-14 listed: 25 mA/250 V, 300 mA/250 V (Low-Voltage Option); Time-Lag IEC 127-3 recognized: 25 mA/250 V, 300 mA/250 V (Low-Voltage Option)
Environmental Conditions (Operating) -20 to +70°C (-4 to +158°F), 90% RH non-condensing
Environmental Conditions (Storage) -40 to +85°C (-40 to +185°F), 90% RH non-condensing
Serial Configuration Default RS485, 115.2k baud, no Parity; baud rates 4800/9600/19200/38400/57600/115200; parity None/Odd/Even
Modbus Address 1 to 247 (default 1)
Scan Time Default 3 seconds
Wiring Copper conductors only, minimum 20 AWG, UL Rated; insulation rated for at least 185°F (85°C) and 600 V; torque all connections to 0.5-5.31 in-lb (0.6 Nm)
Approvals EMC: 2014/30/EU; LVD: 2014/35/EU; UL 61010-1 / CSA C22.2 NO. 61010-1-12; UL 61010-2-201 / CSA C22.2 NO. 61010-2-201:14; UL File Number E209855; WEEE 2012/19/EU
Dimensions 3.74 x 3.74 x 5.31" (95 x 95 x 135 mm)
Weight 1.6 lbs (725 g)

What's included with the OMEGA DP606A-DC

  • Omega DP606A Series Temperature Panel Meter, 2x relay output, 9 to 36 V DC

Ask a question about Omega DP606A Series Temperature Panel Meter, 2x relay output, 9 to 36 V DC

Customer Reviews for the OMEGA DP606A-DC

OMEGA DP606A-DC Offers

The DP606A/DP612A Display Meter offers a flexible, easy to use 6 or 12 zone, 4 digit temperature and process measurement solution in a rugged 1/4 DIN Aluminum housing. Selectable configuration eliminates the need for jumpers. The DP606A supports 6 independent zones (3 wire RTD limited to 6 zones on all models).

The DP606A and DP612A Series is our newest line of affordable multi-channel panel meters. These models offer increased accuracy, wider operating temperatures and increased flexibility over the CN606 and CN612 models that they replace.

All zones are scanned at a 400 ms rate. The display shows the reading of each zone sequentially. High and low Alarms with SPDT relay outputs are available for monitoring and alarm purposes.

The input, power and communications are also now isolated allowing for easier deployment and more reliable operation. The rugged extruded aluminum 1/4 DIN case combines with the improved isolation to provide an extremely durable product.

These meters can read up to 12 sensors and include user selectable RS232 or RS485 communications using Modbus(R). Two user configurable Alarm relays are standard on all models.

The universal input allows user selection between thermocouple (9 types), RTD 2-wire, RTD 3-wire, 4 to 20 mA and 1000 mV input options. These input selections are firmware selectable through the front panel buttons or Modbus serial commands.

Note: While the inputs are universal and can be changed via firmware (no dip switches), all 6 or 12 inputs on a given unit must be set to the same type of input for operation.

Features

  • Flexible, easy to use 6 zone, 4 digit temperature and process measurement solution in a rugged 1/4 DIN aluminum housing
  • Universal TC, RTD and Process Inputs Firmware Selectable
  • Selectable configuration eliminates the need for jumpers
  • User Programmable Alarms Individually Settable per Channel
  • All zones are scanned at a 400 MS rate; the display shows the reading of each zone sequentially
  • Adjustable Scan Time: 400 ms Scan Rate per Channel
  • High and low alarms with spdt relay outputs are available for monitoring and alarm purposes
  • 2 User Assignable Alarm Relays
  • Universal input supports 9 thermocouple types (j, k, t, e, r, s, b, c, and n), 2 or 3 wire rtds (pt 100, ni 120, cu 10), DC voltage (0-1 v DC), or DC current (0 to 24 mA)
  • RS232/RS485 Communications
  • Independent alarms are available for each zone, configurable for above (hi), below (lo) or hi/lo triggering
  • Password Protection
  • User selectable rs232 or rs485 serial port interface is standard on all models and uses the modbus rtu protocol
  • Universal AC power supply accepts 90 to 240 v AC; the isolated DC power option accepts 9 to 36 v DC
  • A security password can be used to prevent front panel tampering of the configuration

Applications

  • Multi-zone temperature monitoring
  • OEM instrumentation temperature monitoring
  • Process measurement and control
  • Automotive and aerospace test stand data acquisition
  • Thermocouple and RTD monitoring
  • Factory automation process monitoring
  • Industrial control panels
  • Power generation plant monitoring
  • Laboratory measurement
  • Multi-channel thermocouple and RTD temperature measurement

OMEGA DP606A-DC Specifications

Series DP606A Series
No. of zones 6 or 12 (RTD 3 wire 6 channels for all models)
Type temperature panel meter
Display 15 mm 7-segment LED
Supply voltage 9 V DC to 36 V DC Supply
Display time 1 to 99 s
Scan time 400 ms
Output type 36 V DC Power & 2x Relay O/P
Input types TC: J, K, T, E, R, S, B, C, N
RTD: 2 or 3 wire (PT100, 0.00385; CU10, 0.00427; NI120, 0.00672)
Process: 4 to 20 mA, 0 to 1 V
Display 4-digit, 7-segment LED; red, 0.83" (21 mm)
Resolution 1°, 1 mV, 0.01 mA
Input Types 9 thermocouple types (J, K, T, E, R, S, B, C, and N), 2 or 3 wire RTDs (Pt 100, Ni 120, Cu 10), DC voltage (0-1 V DC), or DC current (0 to 24 mA)
ADC 24-bit Sigma Delta
Number of Zones 6 independent zones (3 wire RTD limited to 6 zones)
Communications RS232 and RS485 (user selectable) up to 115.2k baud, Modbus protocol (RTU)
Scan Rate 400 ms
Isolation per 1 min, power to alarm relay 2.3k Vac (3.2k Vdc)
Line Voltage/Power 120/240 V AC, 50/60 Hz, 3 W maximum
Isolation per 1 min, power to serial 2.3k Vac (3.2k Vdc)
Low-Voltage/Power Option 9 to 36 V DC, 3 W maximum
Isolation per 1 min, input to serial 500 Vac (720 Vdc)
Communications Selectable RS232 / RS485, Modbus RTU
Alarm relays De-energizes on alarm; latching or non-latching; high, low or hi/low
Protection NEMA-1/Type 1 front bezel
Operating temp -4 to 158°F (-20 to 70°C)
Process Voltage Accuracy ± 1 mV (0 to 1000 mV)
Storage temp -40 to 185°F (-40 to 85°C)
Process Current Accuracy ± 10 μA (0 to 24.00 mA)
Panel cutout 1/4 DIN 3.6 x 3.6" (92 x 92 mm)
Panel Cutout 1/4 DIN, 3.62 x 3.62" (92 x 92 mm)
Min rear panel depth 5.5" (140 mm)
Pollution Degree 2
ECCN EAR99
Altitude Up to 2000 meters
Safety 2014/35/EU
Alarm Relays AC Power Option 2x SPDT, 240 V AC, 5 A Load
EMC 2014/30/EU
Alarm Relays DC Power Option 2x SPDT, 36 V DC, 3 A Load
RoHS 2011/65/EU
Operating Environmental Conditions -4 to 158°F (-20 to 70°C), 90% RH non-condensing
UL file no. E209855, UL/cUL Listed
Storage Environmental Conditions -40 to 185°F (-40 to 85°C), 90% RH non-condensing
Power DC
Input Accuracy, Type J -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 2192°F (0 to 1200°C) ±1.0°C
Zones 6
Input Accuracy, Type K -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to -2438°F (0 to -1372°C) ±1.0°C (CHROMEGA-ALOMEGA)
Input power 9 to 36 Vdc, 3 watts maximum
Input Accuracy, Type T -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 752°F (0 to 400°C) ±1.0°C (Copper-Constantan)
Isolation per 1 min, power to input 1.5k Vdc
Input Accuracy, Type E -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 1832°F (0 to 1000°C) ±1.0°C (CHROMEGA-Constantan)
Alarm relays rating 36 Vdc max, 3A max load
Input Accuracy, Type R -58 to 32°F (-50 to 0°C) ±1.0°C (25°C); 32 to 3250°F (0 to 1788°C) ±1.0°C (Pt/13%Rh-Pt)
Dimensions 3.7 x 3.7 x 5.3" (95 L x 95 W x 135 Dia mm)
Input Accuracy, Type S -58 to 32°F (-50 to 0°C) ±1.0°C (25°C); 32 to 3214°F (0 to 1768°C) ±1.0°C (Pt/10%Rh-Pt)
Weight 26 oz (725 g)
Input Accuracy, Type B 302 to 1292°F (150 to 700°C) ±1.0°C (25°C); 1292 to 3308°F (700 to 1820°C) ±1.0°C (30%Rh-Pt/6%Rh-Pt)
Input Accuracy, Type C 5%Re-W/26%Re-W 32 to 4208°F (0 to 2320°C) ±1.0°C (25°C)
Input Accuracy, Type N -238 to 32°F (-150 to 0°C) ±1.0°C (25°C); 32 to 2372°F (0 to 1300°C) ±1.0°C (Nicrosil-Nisil)
Input Accuracy, RTD Pt Pt, 0.00385, 100 Ω, 2/3 Wire, -328 to 1562°F (-200 to 850°C) ±1.0°C
Input Accuracy, RTD Cu Cu, 0.00427, 10 Ω, 2/3 Wire, -328 to 500°F (-200 to 260°C) ±1.0°C
Input Accuracy, RTD Ni Ni, 0.00672, 120 Ω, 2/3 Wire, -112 to 500°F (-80 to 260°C) ±1.0°C
Absolute Maximum Input 3.3 V (Process Voltage) or 30mA (Process Current)
External Fuse Required Time-Delay UL 248-14 listed: 25 mA/250 V, 300 mA/250 V (Low-Voltage Option); Time-Lag IEC 127-3 recognized: 25 mA/250 V, 300 mA/250 V (Low-Voltage Option)
Environmental Conditions (Operating) -20 to +70°C (-4 to +158°F), 90% RH non-condensing
Environmental Conditions (Storage) -40 to +85°C (-40 to +185°F), 90% RH non-condensing
Serial Configuration Default RS485, 115.2k baud, no Parity; baud rates 4800/9600/19200/38400/57600/115200; parity None/Odd/Even
Modbus Address 1 to 247 (default 1)
Scan Time Default 3 seconds
Wiring Copper conductors only, minimum 20 AWG, UL Rated; insulation rated for at least 185°F (85°C) and 600 V; torque all connections to 0.5-5.31 in-lb (0.6 Nm)
Approvals EMC: 2014/30/EU; LVD: 2014/35/EU; UL 61010-1 / CSA C22.2 NO. 61010-1-12; UL 61010-2-201 / CSA C22.2 NO. 61010-2-201:14; UL File Number E209855; WEEE 2012/19/EU
Dimensions 3.74 x 3.74 x 5.31" (95 x 95 x 135 mm)
Weight 1.6 lbs (725 g)

What's included with the OMEGA DP606A-DC

  • Omega DP606A Series Temperature Panel Meter, 2x relay output, 9 to 36 V DC

Ask a question about Omega DP606A Series Temperature Panel Meter, 2x relay output, 9 to 36 V DC