Omega DR-I3P DIN Rail Signal Conditioner, Universal Input, 0-10 V / 4-20 mA Output

Model: DR-I3P

Omega DR-I3P DIN Rail Signal Conditioner, Universal Input, 0-10 V / 4-20 mA Output

Model: DR-I3P

Designed for DIN-rail mounting, this isolated signal conditioner accepts thermocouple, RTD, resistance, current, and voltage inputs. It provides a 0 to 10 V and 4 to 20 mA output and runs on an AC or DC supply. Great for process measurement and control loops.

Designed for DIN-rail mounting, this isolated signal conditioner accepts thermocouple, RTD, resistance, current, and voltage inputs. It provides a 0 to 10 V and 4 to 20 mA output and runs on an AC or DC supply. Great for process measurement and control loops.

Your Price $242.19 USD
Availability 2 to 3 Weeks
Quantity

OMEGA DR-I3P Offers

OMEGA's new isolated signal converter delivers high-performance for integration in a wide range of industrial applications. The DR-I3P accepts universal inputs including mA and Vdc process signals (provides +15 Vdc excitation voltage), usual temperature signals such as Pt100, Pt500, Pt1000, Ni100, Ni1000, NTC, thermocouples J, K, N, E, T, R and S, resistances and potentiometer signals, offering application flexibility for signal acquisition and industrial requirements.

A single universal AC/DC power supply allows this unit to be suited for global use. Configurable output in 4/20 mA or 0/10 Vdc, high levels of isolation and DIN rail mount.

Additional features of the DR-I3P isolated signal converter include ready to use 'out of the box' unit, with no additional configuration tools needed, easy configuration by programming codes, and special 'force' functions for installation testing.

Features

  • 'Force' functions - Built in 'Force Low' and 'Force High' functions provide an easy way to generate 4 and 20 mA output signals (or 0 and 10 Vdc) to easily validate connections to remote instruments, such as PLCs.
  • Isolation - 3 way isolation to protect your remote systems from signals noise and ground loops, delivering better performance.
  • Easy configuration with codes from 00 to 99 and predefined input ranges. No additional tools needed for configuration, can be installed 'out of the box'.
  • Password Protection to protect your configuration
  • Universal power supply - Real universal power supply from 18 to 265 Vac/dc, allows for global use and consolidation of stock references.
  • High quality plug-in screw terminals for easy maintenance and replacements.

Applications

  • Signal conversion on a production assembly line
  • Converting process and temperature signals at a control panel
  • Laboratory signal acquisition and measurement
  • Generating 4 to 20 mA or 0 to 10 Vdc signals to validate PLC connections
  • Isolating thermocouple and RTD signals from ground loops and noise

OMEGA DR-I3P Specifications

Input signal - Process 4/20 mA (active and passive, max 25 mA, Vterm <1.2 Vdc), 0/10 Vdc (max. 25 Vdc, Zin=1 MOhm)
Input signal - Excitation voltage +15 Vdc (@30 mA)
Input signal - Thermocouple J, K, N, E, T, R and S (automatic compensation for the thermocouple cold junction)
Input signal - 'Pt' and 'Ni' probes Pt100 (2 and 3 wires, with automatic cable compensation up to 30 Ohm), Pt500, Pt1000, Ni100, Ni1000 (2 wires)
Input signal - 'NTC' probes NTC (with R25=10K, Beta=3500), NTC 44006
Input signal - Resistances ranges for 100 K, 50 K, 25 K, 5 K and 2.5 KOhms
Input signal - Potentiometers nominal from 500 Ohm up to 20 KOhm potentiometers
Thermal stability 150 ppm/°C
Step response 300 mSec. (0% to 99% of signal)
Output signal - 4/20 mA active max. 22 mA, min. 1.5 mA, load <400 Ohm
Output signal - 4/20 mA passive max. 30 Vdc on terminals
Output signal - 0/10 Vdc max. 11 Vdc, min. -1 Vdc, load >1 KOhm
Configuration display 2 digits, 7 segments, 5 mm height, red color
Configuration keypad 2 keys
Power 18 to 265 Vac/dc (isolated 2500 Veff) (20 to 240 Vac/dc ±10%)
AC frequency 45 to 65 Hz
Consumption <1.5 W
Power terminals plug-in screw terminals (5.08 mm pitch)
Power wires 1 mm2 to 2.5 mm2 (AWG17 to AWG14)
Overvoltage category 2
Isolation input - output 2300 Veff (60 seconds)
Isolation power - input 2300 Veff (60 seconds)
Isolation power - output 2300 Veff (60 seconds)
Operation temperature 32 to 122°F (0 to +50°C)
Storage temperature -4 to 158°F (-20 to +70°C)
Warm-up time 15 minutes
Mounting standard DIN rail (35 x 7.5 mm)
Connections plug-in screw terminals (pitch 5.08 mm)
Housing material polyamide V0
IP protection IP30
Impact protection IK06
Packing box 4.72" x 4.53" x 1.18" (120 x 115 x 30 mm), cardboard
Dimensions 4.17" x 4.25" x 0.89" (106 x 108 x 22.5 mm)
Weight <150 gr (5.3 oz)

What's included with the OMEGA DR-I3P

  • Isolated Signal Converter With 85/265 Vac/dc Power Supply
  • Quick Installation Guide
  • Male and Female Plug-in Screw Terminals

Ask a question about Omega DR-I3P DIN Rail Signal Conditioner, Universal Input, 0-10 V / 4-20 mA Output

Customer Reviews for the OMEGA DR-I3P

OMEGA DR-I3P Offers

OMEGA's new isolated signal converter delivers high-performance for integration in a wide range of industrial applications. The DR-I3P accepts universal inputs including mA and Vdc process signals (provides +15 Vdc excitation voltage), usual temperature signals such as Pt100, Pt500, Pt1000, Ni100, Ni1000, NTC, thermocouples J, K, N, E, T, R and S, resistances and potentiometer signals, offering application flexibility for signal acquisition and industrial requirements.

A single universal AC/DC power supply allows this unit to be suited for global use. Configurable output in 4/20 mA or 0/10 Vdc, high levels of isolation and DIN rail mount.

Additional features of the DR-I3P isolated signal converter include ready to use 'out of the box' unit, with no additional configuration tools needed, easy configuration by programming codes, and special 'force' functions for installation testing.

Features

  • 'Force' functions - Built in 'Force Low' and 'Force High' functions provide an easy way to generate 4 and 20 mA output signals (or 0 and 10 Vdc) to easily validate connections to remote instruments, such as PLCs.
  • Isolation - 3 way isolation to protect your remote systems from signals noise and ground loops, delivering better performance.
  • Easy configuration with codes from 00 to 99 and predefined input ranges. No additional tools needed for configuration, can be installed 'out of the box'.
  • Password Protection to protect your configuration
  • Universal power supply - Real universal power supply from 18 to 265 Vac/dc, allows for global use and consolidation of stock references.
  • High quality plug-in screw terminals for easy maintenance and replacements.

Applications

  • Signal conversion on a production assembly line
  • Converting process and temperature signals at a control panel
  • Laboratory signal acquisition and measurement
  • Generating 4 to 20 mA or 0 to 10 Vdc signals to validate PLC connections
  • Isolating thermocouple and RTD signals from ground loops and noise

OMEGA DR-I3P Specifications

Input signal - Process 4/20 mA (active and passive, max 25 mA, Vterm <1.2 Vdc), 0/10 Vdc (max. 25 Vdc, Zin=1 MOhm)
Input signal - Excitation voltage +15 Vdc (@30 mA)
Input signal - Thermocouple J, K, N, E, T, R and S (automatic compensation for the thermocouple cold junction)
Input signal - 'Pt' and 'Ni' probes Pt100 (2 and 3 wires, with automatic cable compensation up to 30 Ohm), Pt500, Pt1000, Ni100, Ni1000 (2 wires)
Input signal - 'NTC' probes NTC (with R25=10K, Beta=3500), NTC 44006
Input signal - Resistances ranges for 100 K, 50 K, 25 K, 5 K and 2.5 KOhms
Input signal - Potentiometers nominal from 500 Ohm up to 20 KOhm potentiometers
Thermal stability 150 ppm/°C
Step response 300 mSec. (0% to 99% of signal)
Output signal - 4/20 mA active max. 22 mA, min. 1.5 mA, load <400 Ohm
Output signal - 4/20 mA passive max. 30 Vdc on terminals
Output signal - 0/10 Vdc max. 11 Vdc, min. -1 Vdc, load >1 KOhm
Configuration display 2 digits, 7 segments, 5 mm height, red color
Configuration keypad 2 keys
Power 18 to 265 Vac/dc (isolated 2500 Veff) (20 to 240 Vac/dc ±10%)
AC frequency 45 to 65 Hz
Consumption <1.5 W
Power terminals plug-in screw terminals (5.08 mm pitch)
Power wires 1 mm2 to 2.5 mm2 (AWG17 to AWG14)
Overvoltage category 2
Isolation input - output 2300 Veff (60 seconds)
Isolation power - input 2300 Veff (60 seconds)
Isolation power - output 2300 Veff (60 seconds)
Operation temperature 32 to 122°F (0 to +50°C)
Storage temperature -4 to 158°F (-20 to +70°C)
Warm-up time 15 minutes
Mounting standard DIN rail (35 x 7.5 mm)
Connections plug-in screw terminals (pitch 5.08 mm)
Housing material polyamide V0
IP protection IP30
Impact protection IK06
Packing box 4.72" x 4.53" x 1.18" (120 x 115 x 30 mm), cardboard
Dimensions 4.17" x 4.25" x 0.89" (106 x 108 x 22.5 mm)
Weight <150 gr (5.3 oz)

What's included with the OMEGA DR-I3P

  • Isolated Signal Converter With 85/265 Vac/dc Power Supply
  • Quick Installation Guide
  • Male and Female Plug-in Screw Terminals

Ask a question about Omega DR-I3P DIN Rail Signal Conditioner, Universal Input, 0-10 V / 4-20 mA Output

Customer Reviews for the OMEGA DR-I3P

More OMEGA Products