Omega HHC280 Series Manometer, differential, 0 to 1.5 psi

Model: HHC280

Omega HHC280 Series Manometer, differential, 0 to 1.5 psi-

Image is for reference only, refer to product info for complete details.

Omega HHC280 Series Manometer, differential, 0 to 1.5 psi

Model: HHC280

Configured for Differential, 0 inH2O (0 mbar) to 40.19 inH2O (100 mbar), ± 1.6 %, this manometer suits hvac system troubleshooting and air velocity measurement with pitot tubes.

Configured for Differential, 0 inH2O (0 mbar) to 40.19 inH2O (100 mbar), ± 1.6 %, this manometer suits hvac system troubleshooting and air velocity measurement with pitot tubes.

Sale Price $161.98 USD
Regular Price $171.41 USD
Availability 2 to 3 Weeks
Quantity

OMEGA HHC280 Offers

The HHC280 is a rugged handheld differential manometer with rubber bumper and cover for field engineering. The HHC281 is a rugged handheld absolute pressure meter with barometric and altitude measurement and calculation of barometric pressure. Both meters feature dual inputs and eight selectable units.

Features

  • Eight selectable units
  • Dual inputs p1 and p2
  • Functions: hold/min/max/max-minimum/avg
  • Auto power-off (10 minutes)
  • Backlight with auto-off (15 seconds)
  • HVAC system troubleshooting
  • Gas pressure measurements
  • Compliant for pitot tubes for measuring air velocity
  • High accuracy absolute pressure measurement
  • Barometric and altitude measurement
  • Calculation of barometric pressure
  • All models include slip-off hard cover shell

Applications

  • HVAC system troubleshooting
  • Gas pressure measurement
  • Air velocity measurement with pitot tubes
  • Barometric pressure and altitude measurement
  • Field engineering pressure diagnostics

OMEGA HHC280 Specifications

Series HHC280 Series
Type manometer
Configuration Differential
Configuration 0 inH2O (0 mbar) to 40.19 inH2O (100 mbar)
Accuracy ± 1.6 %
Units °C or °F
Operating Temperature 32 to 122°F (0 to 50°C)
Power 2" (5.1 cm)AAA" batteries (included)
Functions Hold/Min/Max/Max-Min/AVG
Auto Power-Off 10 Minutes
Backlight Auto-Off (15 Seconds)
Included Comes complete with batteries, carrying strap, and protection cap
Inputs (HHC280 Differential Manometer) Dual Inputs P1 and P2
Eight Selectable Units (HHC280) mmH2O, mmHg, psi, inH2O, inHg, hPa, mbar, Pa, plus m/s and fpm (for air velocity)
Range (HHC280) 0 to 2.95 inHg (0 to 100 hPa)/0 to 40.15 inH2O (1019.7 mmH2O)
Resolution (HHC280) 0 inHg (0.1 hPa)/0 inH2O (0.1 mmH2O)
Per-Unit Range/Resolution (HHC280) mmH2O 0 to 1019.7 (0.1); mmHg 0 to 75.00 (0.01); psi 0 to 1.450 (0.001); inH2O 0 to 40.14 (0.01); inHg 0 to 2953 (0.001); hPa 0 to 100.00 (0.01); mbar 0 to 100.00 (0.01); Pa 0 to 10000 (1); FPM (1); m/s (0.1)
Battery Life (HHC280) 85 hours typical with alkaline batteries
Eight Selectable Units (HHC281 Absolute Pressure Meter) hPa, mbar, Pa, mmH2O, mmHg, inH2O, inHg, psi, plus m and ft (for altitude)
Range (HHC281) 8.86 to 35.44 inHg (300 to 1200 hPa)
Resolution (HHC281) 0 inHg (0.1 hPa)
Barometric/Altitude (HHC281) Barometric and Altitude Measurement; Calculation of Barometric Pressure
Battery Life (HHC281) 600 hours typical with alkaline batteries
Dimensions 0.98 x 2.0 x 5.2" (24.7 x 50.9 x 132.9 mm)
Weight (HHC280) 4.0 oz (113 g)
Weight (HHC281) 4.2 oz (120 g)

What's included with the OMEGA HHC280

  • Omega HHC280 Series Manometer, differential, 0 to 1.5 psi

Ask a question about Omega HHC280 Series Manometer, differential, 0 to 1.5 psi

Customer Reviews for the OMEGA HHC280

OMEGA HHC280 Offers

The HHC280 is a rugged handheld differential manometer with rubber bumper and cover for field engineering. The HHC281 is a rugged handheld absolute pressure meter with barometric and altitude measurement and calculation of barometric pressure. Both meters feature dual inputs and eight selectable units.

Features

  • Eight selectable units
  • Dual inputs p1 and p2
  • Functions: hold/min/max/max-minimum/avg
  • Auto power-off (10 minutes)
  • Backlight with auto-off (15 seconds)
  • HVAC system troubleshooting
  • Gas pressure measurements
  • Compliant for pitot tubes for measuring air velocity
  • High accuracy absolute pressure measurement
  • Barometric and altitude measurement
  • Calculation of barometric pressure
  • All models include slip-off hard cover shell

Applications

  • HVAC system troubleshooting
  • Gas pressure measurement
  • Air velocity measurement with pitot tubes
  • Barometric pressure and altitude measurement
  • Field engineering pressure diagnostics

OMEGA HHC280 Specifications

Series HHC280 Series
Type manometer
Configuration Differential
Configuration 0 inH2O (0 mbar) to 40.19 inH2O (100 mbar)
Accuracy ± 1.6 %
Units °C or °F
Operating Temperature 32 to 122°F (0 to 50°C)
Power 2" (5.1 cm)AAA" batteries (included)
Functions Hold/Min/Max/Max-Min/AVG
Auto Power-Off 10 Minutes
Backlight Auto-Off (15 Seconds)
Included Comes complete with batteries, carrying strap, and protection cap
Inputs (HHC280 Differential Manometer) Dual Inputs P1 and P2
Eight Selectable Units (HHC280) mmH2O, mmHg, psi, inH2O, inHg, hPa, mbar, Pa, plus m/s and fpm (for air velocity)
Range (HHC280) 0 to 2.95 inHg (0 to 100 hPa)/0 to 40.15 inH2O (1019.7 mmH2O)
Resolution (HHC280) 0 inHg (0.1 hPa)/0 inH2O (0.1 mmH2O)
Per-Unit Range/Resolution (HHC280) mmH2O 0 to 1019.7 (0.1); mmHg 0 to 75.00 (0.01); psi 0 to 1.450 (0.001); inH2O 0 to 40.14 (0.01); inHg 0 to 2953 (0.001); hPa 0 to 100.00 (0.01); mbar 0 to 100.00 (0.01); Pa 0 to 10000 (1); FPM (1); m/s (0.1)
Battery Life (HHC280) 85 hours typical with alkaline batteries
Eight Selectable Units (HHC281 Absolute Pressure Meter) hPa, mbar, Pa, mmH2O, mmHg, inH2O, inHg, psi, plus m and ft (for altitude)
Range (HHC281) 8.86 to 35.44 inHg (300 to 1200 hPa)
Resolution (HHC281) 0 inHg (0.1 hPa)
Barometric/Altitude (HHC281) Barometric and Altitude Measurement; Calculation of Barometric Pressure
Battery Life (HHC281) 600 hours typical with alkaline batteries
Dimensions 0.98 x 2.0 x 5.2" (24.7 x 50.9 x 132.9 mm)
Weight (HHC280) 4.0 oz (113 g)
Weight (HHC281) 4.2 oz (120 g)

What's included with the OMEGA HHC280

  • Omega HHC280 Series Manometer, differential, 0 to 1.5 psi

Ask a question about Omega HHC280 Series Manometer, differential, 0 to 1.5 psi

Customer Reviews for the OMEGA HHC280

More OMEGA Products