Designed for linear position measurement, this stainless-steel LVDT sensor measures a 0-10 mm stroke. It provides a 0 to 10 V DC output with ±0.25% linearity. Housed in a 0.79" (20.07 mm) diameter, 4.5" (113.5 mm) body with a 1 m (3.3 ft) cable, it works great for position feedback and automated gauging.
Designed for linear position measurement, this stainless-steel LVDT sensor measures a 0-10 mm stroke. It provides a 0 to 10 V DC output with ±0.25% linearity. Housed in a 0.79" (20.07 mm) diameter, 4.5" (113.5 mm) body with a 1 m (3.3 ft) cable, it works great for position feedback and automated gauging.
The LD620 DC output displacement tranducers have improved IP67-rated sealing, coupled with new polymer guides with rigid carriers. These transducers are accurate and reliable, especially in wet and corrosive conditions.
An unusually large bore-to-core clearance is maintained throughout the range. This makes installation easier and helps prevent misalignment.
Features
Applications
| Linearity | <0.2% FSO |
| Excitation voltage | 10 to 30 Vdc @ 25 mA maximum |
| Output | 0 to 10 Vdc |
| Output ripple | 0.02% FSO |
| Bandwidth | 500 Hz (-3 dB) |
| Storage temp | -4 to 185°F (-20 to 85°C) |
| Operating temp | 32 to 149°F (0 to 65°C) |
| Sealing | IP67 |
| Vibration (sinusoidal frequency) | 10 to 50 Hz: 1 to 10 g rms linear amplitude 50 Hz to 1 kHz: 10 g rms amplitude |
| Shock | Drop testing: 3' (1 m) onto hard surface Topple testing: 10 times each end onto hard surface |
| Case material | 300 SS |
| Cable | PFA, 6' (2 m) long |
| Core material | Nickel-iron |
| Range | 0 to 10 mm (0 to 0.4") |
| Dimensions | "A" body length: 4.5" (113.5 mm) "B" fully extended: 1.8" (46.3 mm) |
| Linearity | <0.2% FSO |
| Excitation voltage | 10 to 30 Vdc @ 25 mA maximum |
| Output | 0 to 10 Vdc |
| Output ripple | 0.02% FSO |
| Bandwidth | 500 Hz (-3 dB) |
| Storage temp | -4 to 185°F (-20 to 85°C) |
| Operating temp | 32 to 149°F (0 to 65°C) |
| Sealing | IP67 |
| Vibration (sinusoidal frequency) | 10 to 50 Hz: 1 to 10 g rms linear amplitude 50 Hz to 1 kHz: 10 g rms amplitude |
| Shock | Drop testing: 3' (1 m) onto hard surface Topple testing: 10 times each end onto hard surface |
| Case material | 300 SS |
| Cable | PFA, 6' (2 m) long |
| Core material | Nickel-iron |
| Range | 0 to 10 mm (0 to 0.4") |
| Dimensions | "A" body length: 4.5" (113.5 mm) "B" fully extended: 1.8" (46.3 mm) |