Made for linear position measurement, this stainless-steel LVDT sensor measures a 0-100 mm stroke. It provides a 4 to 20 mA output with ±0.5% linearity. Housed in a 0.79" (20.07 mm) diameter, 11.57" (293.88 mm) body with a 1 m (3.3 ft) cable, it works great for displacement and linear position feedback.
Made for linear position measurement, this stainless-steel LVDT sensor measures a 0-100 mm stroke. It provides a 4 to 20 mA output with ±0.5% linearity. Housed in a 0.79" (20.07 mm) diameter, 11.57" (293.88 mm) body with a 1 m (3.3 ft) cable, it works great for displacement and linear position feedback.
The LD630 Series current output displacement transmitters have improved IP67-rated sealing, coupled with polymer guides with rigid carriers. These transmitters are accurate and reliable, especially in wet and corrosive conditions.
The direct-acting model will have 4 mA output when the guided core is fully out, and the output will increase to 20 mA when fully in.
Features
Applications
| Linearity | <0.2% FSO |
| Excitation voltage | 10 to 30 Vdc |
| Output | 4 to 20 mA |
| Output ripple | 0.02% FSO |
| Bandwidth | 500 Hz (-3 dB) |
| Storage temp | -4 to 185°F (-20 to 85°C) |
| Operating temp | 32 to 149°F (0 to 65°C) |
| Vibration (sinusoidal frequency) | 10 to 50 Hz: 1 to 10 g rms linear amplitude; 50 Hz to 1 kHz: 10 g rms amplitude |
| Shock | Drop testing: 3' (1 m) onto hard surface; Topple testing: 10 times each end onto hard surface |
| Cable | PFA, 6' (2 m) long |
| Core material | Nickel-iron |
| Range | 0 to 3.9" (0 to 100 mm) |
| Dimensions | "A" body length: 9.0" (228.5 mm) "B" fully extended: 6.3" (160.3 mm) |
| Linearity | <0.2% FSO |
| Excitation voltage | 10 to 30 Vdc |
| Output | 4 to 20 mA |
| Output ripple | 0.02% FSO |
| Bandwidth | 500 Hz (-3 dB) |
| Storage temp | -4 to 185°F (-20 to 85°C) |
| Operating temp | 32 to 149°F (0 to 65°C) |
| Vibration (sinusoidal frequency) | 10 to 50 Hz: 1 to 10 g rms linear amplitude; 50 Hz to 1 kHz: 10 g rms amplitude |
| Shock | Drop testing: 3' (1 m) onto hard surface; Topple testing: 10 times each end onto hard surface |
| Cable | PFA, 6' (2 m) long |
| Core material | Nickel-iron |
| Range | 0 to 3.9" (0 to 100 mm) |