Configured for high-accuracy environmental monitoring, this temperature, humidity, and dew point data logger measures -31 to 176°F (-35 to 80°C) and 0 to 100% RH, storing up to 16,379 readings each. It shows readings on a high-contrast LCD and plugs directly into a USB port. Well suited to laboratory, storage, and clean-room condition logging.
Configured for high-accuracy environmental monitoring, this temperature, humidity, and dew point data logger measures -31 to 176°F (-35 to 80°C) and 0 to 100% RH, storing up to 16,379 readings each. It shows readings on a high-contrast LCD and plugs directly into a USB port. Well suited to laboratory, storage, and clean-room condition logging.
The OM-EL-USB-2-LCD is a standalone data logger that measures and stores up to 16,379 relative humidity and 16,379 temperature readings over 0 to 100% RH and -35 to 80°C (-31 to 176°F) measurement ranges. The high contrast LCD can show a variety of temperature and humidity information. At the touch of a button, the user can cycle between the current temperature and humidity, along with the maximum and minimum stored values for temperature and humidity. In addition, logging and alarm status is shown using two high intensity LEDs. The data logger is supplied with a long-life lithium battery, which can typically allow logging for up to 1 year. The user can easily set up the data logger and down-load logged data by plugging the unit into a PCs USB port and using the supplied Windows software.
Data logger parameters that can be set up include data logger name, °C or °F temperature units, logging rate (10 sec, 30 sec, 1 minutes, 10 minutes, 30 minutes, 1 hr, 6 hrs, 12 hrs), high and low alarms, immediate, delayed or push-to-start logging, display off, on for 30 seconds after button press, or permanently on, and data rollover (allows unlimited logging periods by overwriting the oldest data when the memory is full). Downloaded relative humidity, temperature and dew point data saved in text format can be graphed, printed and exported to other applications for further analysis.
Features
Applications
| Memory | 16,379 temperature and 16,379 relative humidity readings |
| Logging interval | 10 sec to 12 hrs |
| Software | Windows XP/Vista/7 and 8 (32-bit and 64-bit) |
| Operating temperature range | -31 to 176°F (-35 to 80°C); at temperatures below -4°F (-20°C) the LCD display will exhibit slower response times of approx 10 seconds |
| Alarm thresholds | High/low alarm thresholds for %RH and temperature selectable in software |
| Start date/time | Selectable in software |
| Status indicators (LEDs) | Red and green |
| Power | 1/2 AA, 3.6 V lithium battery (included) |
| Battery life | 1 year typical (depends on sample rate, ambient temperature and use of LCD display) |
| Range | -31 to 176°F (-35 to 80°C) |
| Repeatability | ±0.1°C (±0.2°F) |
| Resolution | 0.5°C (1.0°F) |
| Accuracy (OM-EL-USB-2-LCD-PLUS) | ±0.3°C (±0.6°F) typical; ±1.5°C (±3.0°F) maximum |
| Range | 0 to 100% RH |
| Repeatability | ±0.1% RH (short term) |
| Resolution | 0.5% RH |
| Accuracy [20 to 80% RH] (OM-EL-USB-2-LCD-PLUS) | ±2.0% RH typical; ±4.0% RH maximum |
| Accuracy (overall error in the calculated dew point, for RH measurements between 40 to 100% RH @ 25°C) | ±1.1°C (±2°F) |
| Dimensions | 4.96" (126.0 mm) |
| Weight | Weight: 1.4 oz (40 g) |
| Memory | 16,379 temperature and 16,379 relative humidity readings |
| Logging interval | 10 sec to 12 hrs |
| Software | Windows XP/Vista/7 and 8 (32-bit and 64-bit) |
| Operating temperature range | -31 to 176°F (-35 to 80°C); at temperatures below -4°F (-20°C) the LCD display will exhibit slower response times of approx 10 seconds |
| Alarm thresholds | High/low alarm thresholds for %RH and temperature selectable in software |
| Start date/time | Selectable in software |
| Status indicators (LEDs) | Red and green |
| Power | 1/2 AA, 3.6 V lithium battery (included) |
| Battery life | 1 year typical (depends on sample rate, ambient temperature and use of LCD display) |
| Range | -31 to 176°F (-35 to 80°C) |
| Repeatability | ±0.1°C (±0.2°F) |
| Resolution | 0.5°C (1.0°F) |
| Accuracy (OM-EL-USB-2-LCD-PLUS) | ±0.3°C (±0.6°F) typical; ±1.5°C (±3.0°F) maximum |
| Range | 0 to 100% RH |
| Repeatability | ±0.1% RH (short term) |
| Resolution | 0.5% RH |
| Accuracy [20 to 80% RH] (OM-EL-USB-2-LCD-PLUS) | ±2.0% RH typical; ±4.0% RH maximum |
| Accuracy (overall error in the calculated dew point, for RH measurements between 40 to 100% RH @ 25°C) | ±1.1°C (±2°F) |
| Dimensions | 4.96" (126.0 mm) |
| Weight | Weight: 1.4 oz (40 g) |